CoChat

The Use of Silicon Microfabrication Technology in Painless Blood Glucose Monitoring

Smart, Wilson H., Subramanian, Kumar · 2000 · Diabetes Technology & Therapeutics
Cited by 101

The DOI matches its Crossref record.

Abstract

A unique minimally invasive system for painless blood testing is now being commercialized for measurement of blood glucose concentration by diabetics. The novel component of this system, a consumable microsampling and assay device, consists of a tough, flexible silicon microneedle comparable in cross-section to a human hair integrated with a silicon microcuvette. This microneedle is capable of reliably taking a very small sample of whole blood completely painlessly, unlike sticks with the much larger metal lancet that must be used in all other current systems. The device permits a one-step process that avoids the need to transfer blood from a skin puncture to a test strip, thus minimizing blood required and possible mess. The small hand-held instrument containing the consumable is touched to the skin of the arm or any other part of the body, not necessarily the tip of the finger, and held there for one second. During this time, the microneedle is advanced and then withdrawn under microprocessor control, puncturing the skin and drawing less than 200 nanoliters of blood into the microcuvette, where the assay is performed automatically. The instrument calculates the blood glucose concentration, displays the result, and holds it in memory for recall. The consumable is produced by silicon microelectromechanical systems technology and can be produced in high volume at low unit cost. This technology shows promise of being extended to other analytes and to continuous monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/15209150050501961

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 101

Metadata

Authors
Smart, W. H., & Subramanian, K.
Venue
Diabetes Technology & Therapeutics
Published
2000-12-20
Volume
2
Issue
4
Pages
549-559
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2175914780
Cited by
101
References
0
FWCI
0.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Use of Silicon Microfabrication Technology in Painless Blood Glucose Monitoring. https://app.cochat.ai/papers/10.1089/15209150050501961
The paper
Smart, W. H., & Subramanian, K. (2000). The Use of Silicon Microfabrication Technology in Painless Blood Glucose Monitoring. Diabetes Technology & Therapeutics. https://doi.org/10.1089/15209150050501961

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.