The Use of Silicon Microfabrication Technology in Painless Blood Glucose Monitoring
The DOI matches its Crossref record.
Abstract
A unique minimally invasive system for painless blood testing is now being commercialized for measurement of blood glucose concentration by diabetics. The novel component of this system, a consumable microsampling and assay device, consists of a tough, flexible silicon microneedle comparable in cross-section to a human hair integrated with a silicon microcuvette. This microneedle is capable of reliably taking a very small sample of whole blood completely painlessly, unlike sticks with the much larger metal lancet that must be used in all other current systems. The device permits a one-step process that avoids the need to transfer blood from a skin puncture to a test strip, thus minimizing blood required and possible mess. The small hand-held instrument containing the consumable is touched to the skin of the arm or any other part of the body, not necessarily the tip of the finger, and held there for one second. During this time, the microneedle is advanced and then withdrawn under microprocessor control, puncturing the skin and drawing less than 200 nanoliters of blood into the microcuvette, where the assay is performed automatically. The instrument calculates the blood glucose concentration, displays the result, and holds it in memory for recall. The consumable is produced by silicon microelectromechanical systems technology and can be produced in high volume at low unit cost. This technology shows promise of being extended to other analytes and to continuous monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Microneedles for transdermal drug delivery
Prausnitz, M. R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.023 · Cited by 1,521
Microneedle technologies for (trans)dermal drug and vaccine delivery
van der Maaden, K., Jiskoot, W., & Bouwstra, J. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.01.042 · Cited by 651
Tehrani, F., Teymourian, H., Wuerstle, B., Kavner, J., Patel, R., Furmidge, A., Aghavali, R., Hosseini-Toudeshki, H., Brown, C., Zhang, F., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00887-1 · Cited by 625
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
Microneedles: an emerging transdermal drug delivery system
Bariya, S. H., Gohel, M. C., Mehta, T. A., & Sharma, O. P. (2012) · Journal of Pharmacy and Pharmacology · doi:10.1111/j.2042-7158.2011.01369.x · Cited by 455
Microneedle array for transdermal biological fluid extraction and in situ analysis
Mukerjee, E. V., Collins, S. D., Isseroff, R. R., & Smith, R. L. (2004) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2003.11.008 · Cited by 340
Clinical administration of microneedles: skin puncture, pain and sensation
Haq, M. I., Smith, E., John, D. N., Kalavala, M., Edwards, C., Anstey, A., Morrissey, A., & Birchall, J. C. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9208-1 · Cited by 329
Lab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310
Minimally Invasive Extraction of Dermal Interstitial Fluid for Glucose Monitoring Using Microneedles
Wang, P. M., Cornwell, M., & Prausnitz, M. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.131 · Cited by 267
Microinfusion Using Hollow Microneedles
Martanto, W., Moore, J. S., Kashlan, O., Kamath, R., Wang, P. M., O'Neal, J. M., & Prausnitz, M. R. (2006) · Pharmaceutical Research · doi:10.1007/s11095-005-8498-8 · Cited by 262
DORAISWAMY, A., JIN, C., NARAYAN, R., MAGESWARAN, P., MENTE, P., MODI, R., AUYEUNG, R., CHRISEY, D., OVSIANIKOV, A., & CHICHKOV, B. (2006) · Acta Biomaterialia · doi:10.1016/j.actbio.2006.01.004 · Cited by 245
Microneedle biomedical devices
Zheng, M., Sheng, T., Yu, J., Gu, Z., & Xu, C. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00141-6 · Cited by 235
Microneedles for transdermal diagnostics: Recent advances and new horizons
Liu, G.-S., Kong, Y., Wang, Y., Luo, Y., Fan, X., Xie, X., Yang, B.-R., & Wu, M. X. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2019.119740 · Cited by 231
“Such long HMNs have been fabricated using silicon (Si) [81], polymers [82,83], and metals [84,85].”
BackgroundMicroneedles for transdermal drug delivery: a systematic review
Dharadhar, S., Majumdar, A., Dhoble, S., & Patravale, V. (2019) · Drug Development and Industrial Pharmacy · doi:10.1080/03639045.2018.1539497 · Cited by 188
“Silicon can be used for the production of solid [1,3,32,33], hollow [14,15,18,34], and coated MNs [34].”
BackgroundMethodInfluentialA practical guide to the development of microneedle systems – In clinical trials or on the market
Lee, K. J., Jeong, S. S., Roh, D. H., Kim, D. Y., Choi, H.-K., & Lee, E. H. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2019.118778 · Cited by 173
Clinical microneedle injection of methyl nicotinate: stratum corneum penetration
Sivamani, R. K., Stoeber, B., Wu, G. C., Zhai, H., Liepmann, D., & Maibach, H. (2005) · Skin Research and Technology · doi:10.1111/j.1600-0846.2005.00107.x · Cited by 171
“Inplane microneedles have been integrated with circuitry, pumps, and sensors (5–7) and have been used in clinical tests to measure blood glucose levels (8).”
MethodMicroneedle mediated delivery of nanoparticles into human skin
Coulman, S. A., Anstey, A., Gateley, C., Morrissey, A., McLoughlin, P., Allender, C., & Birchall, J. C. (2009) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.08.040 · Cited by 166
Innovative Strategies for Enhancing Topical and Transdermal Drug Delivery
Morrow, D. I. J., McCarron, P. A., Woolfson, A. D., & Donnelly, R. F. (2007) · The Open Drug Delivery Journal · doi:10.2174/1874126600701010036 · Cited by 162
“Smart and Subramanian [240] described a novel MN-based system designed to painlessly monitor blood glucose.”
BackgroundVenugopal, M., Feuvrel, K. E., Mongin, D., Bambot, S., Faupel, M., Panangadan, A., Talukder, A., & Pidva, R. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2007.912544 · Cited by 76
“Assays have been developed for measuring glucose and lactate concentrations [32], [33].”
Metadata
- Authors
- Smart, W. H., & Subramanian, K.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2000-12-20
- Volume
- 2
- Issue
- 4
- Pages
- 549-559
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2175914780
- Cited by
- 101
- References
- 0
- FWCI
- 0.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.