Comparison of Glucose Levels in Dermal Interstitial Fluid and Finger Capillary Blood
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Alternative methods for self-monitoring of blood glucose have been pursued by many researchers, largely in response to evidence gathered in several long-term studies of patients with diabetes mellitus. These studies suggest that long-term complications of the disease may be mitigated if the disease is intensively managed, a component of which is increased monitoring. Many of the alternative methods utilize interstitial fluid (ISF) as the diagnostic fluid, rather than finger blood. A time lag in the distribution of glucose from blood to the interstitium has been observed by many, with estimates of lag time varying from none to 45 min. Dermal ISF was sampled from diabetic subjects in two tests and compared to finger blood glucose. In the first test, data were collected over time in a manner that allowed a cross-correlation analysis to predict an average lag time. Information from this test was then used as input to a data collection format for a method comparison test of 691 patients with diabetes in which ISF data were collected immediately after the finger blood reference and 15 min after the reference. An average lag time of about 25 min was determined from the cross-correlation analysis, with the correlation error reduced by three-fourths within a 15-min lag time. In the method comparison test, the correlation coefficient between finger blood glucose and ISF glucose improved from 0.923 to 0.951, and the percentage of data in the A zone of the Clarke Error Grid rose from 80.2% to 90.6% for the ISF glucose data collected at no lag and 15-min lag, respectively. Dermal ISF glucose measurement might be a reasonable alternative to blood glucose measurement for patients routinely monitoring ambient glycemia, although more testing in the sensitive hypoglycemic range is needed to clarify what might happen in cases of rapidly changing glucose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jungheim, K., & Koschinsky, T. (2002) · Diabetes Care · doi:10.2337/diacare.25.6.956 · Cited by 114
Cited by
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
“A plasma and dermal interstitial glucose concentration lag time of 10–20 min was reported by Stout et al.(29) A recent modeling study using skin biopsy specimens of the lower leg revealed a lag time of 1–3 min in the dermis.”
Sampling interstitial fluid from human skin using a microneedle patch
Samant, P. P., Niedzwiecki, M. M., Raviele, N., Tran, V., Mena-Lapaix, J., Walker, D. I., Felner, E. I., Jones, D. P., Miller, G. W., & Prausnitz, M. R. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw0285 · Cited by 379
Performance Evaluation of the MiniMed® Continuous Glucose Monitoring System During Patient Home Use
Gross, T. M., Bode, B. W., Einhorn, D., Kayne, D. M., Reed, J. H., White, N. H., & Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/152091500316737 · Cited by 303
Minimally Invasive Extraction of Dermal Interstitial Fluid for Glucose Monitoring Using Microneedles
Wang, P. M., Cornwell, M., & Prausnitz, M. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.131 · Cited by 267
Metadata
- Authors
- Stout, P. J., Peled, N., Erickson, B. J., Hilgers, M. E., Racchini, J. R., & Hoegh, T. B.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2001-03
- Volume
- 3
- Issue
- 1
- Pages
- 81-90
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2038249947
- Cited by
- 75
- References
- 1
- FWCI
- 1.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Glucose Levels in Dermal Interstitial Fluid and Finger Capillary Blood. https://app.cochat.ai/papers/10.1089/152091501750220046
- The paper
- Stout, P. J., Peled, N., Erickson, B. J., Hilgers, M. E., Racchini, J. R., & Hoegh, T. B. (2001). Comparison of Glucose Levels in Dermal Interstitial Fluid and Finger Capillary Blood. Diabetes Technology & Therapeutics. https://doi.org/10.1089/152091501750220046
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.