Variability of Insulin Absorption and Insulin Action
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Subcutaneous (s.c.) injections of identical insulin doses may lead to considerable intra- and inter-individual differences in the current metabolic control of patients with diabetes mellitus. This well-known variability of the metabolic effect of insulin hampers practical insulin therapy considerably. The aim of this review is to summarize the knowledge about this topic, with a special focus on the variability of insulin action after pulmonary administration of insulin. A number of studies have been published describing the variability of insulin absorption from the s.c. depot. Only in a few published studies has the variability of insulin action after s.c. administration been quantified. Under controlled experimental conditions s.c. injections of regular insulins result in an intra-individual coefficient of variation (CV) of 15-25% of certain pharmacodynamic summary measures--which characterize the metabolic effect of the applied insulin--in healthy subjects. The inter-individual variability was approximately 10% higher than the intra-individual variability. Subcutaneously injected intermediate- and long-acting insulin preparations were described to have an even greater variability (> 50%) than subcutaneously injected regular insulin. However, in a glucose clamp study s.c. application of NPH insulin led to an intra-individual CV in the range of 12-45% in healthy subjects. The reason for this discrepancy might be that the NPH insulin suspension was sufficiently shaken prior to drawing up the dose. Compared with conventional insulin formulations, rapid- and long-acting insulin analogues appear to have a similar variability, which means that, unfortunately, no considerable advantages in terms of variability were achieved by the invention of these novel insulin preparations. There are no appropriate studies available investigating the variability of the metabolic effect after s.c. insulin administration in patients with diabetes. The inhalation of insulin is a novel form of insulin administration that is currently under clinical development. The variability of the metabolic effect induced by the inhalation of insulin has up to now only been investigated in a small number of (published) studies. In a glucose-clamp study with healthy subjects the inhalation of an identical insulin dose on three study days led to an intra-individual variability that was comparable to that after s.c. injection of regular insulin. In a dose-response study with patients with type 1 diabetes the intra-individual CV was 34% for the area under the curve of the glucose infusion rate for 0-10 h. Studies with patients with type 2 diabetes have shown that the intra-individual CVs were within the range seen after s.c. insulin administration or even lower. In summary, the intra-individual variability of the metabolic effect observed after insulin application, be it subcutaneously injected or be it inhaled, is considerable and, therefore, hampers practical diabetes therapy. To date no means have been found that could lead to a clinically relevant reduction in the variable metabolic effect.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, this approach increases the risk of hypoglycemia if emptying accelerates unpredictably or hyperglycemia if the delay worsens [113, 114].”
From Diabetic gastroparesis: pathophysiology and impact on insulin timing choices (2026) · cites this paper as [113]
In the citing paper
“In consistently slow gastric emptying, switching from rapid-acting insulin analogues to regular human insulin may be beneficial, as its slower onset (30–60 min) and longer duration (6–8 h) can better match the delayed absorption of carbohydrates [3, 14, 92, 113, 114].”
From Diabetic gastroparesis: pathophysiology and impact on insulin timing choices (2026) · cites this paper as [113]
In the citing paper
“The mechanisms that cause variable and unreliable insulin absorption from a CSII catheter into the circulation are poorly understood.”
From Detailed Analysis of Insulin Absorption Variability and the Tissue Response to Continuous Subcutaneous Insulin Infusion Catheter Implantation in Swine (2017) · cites this paper as [11]
Citations
Cites
Long-Term Complications of Diabetes Mellitus
Nathan, D. M. (1993) · New England Journal of Medicine · doi:10.1056/nejm199306103282306 · Cited by 1,495
Binder, C., Lauritzen, T., Faber, O., & Pramming, S. (1984) · Diabetes Care · doi:10.2337/diacare.7.2.188 · Cited by 341
Absorption of Injected Insulin: A Clinical‐Pharmacological Study
BINDER, C. (1969) · Acta Pharmacologica et Toxicologica · doi:10.1111/j.1600-0773.1969.tb03069.x · Cited by 287
Absorption Kinetics and Biologic Effects of Subcutaneously Injected Insulin Preparations
Berger, M., Cüppers, H. J., Hegner, H., Jörgens, V, & Berchtold, P. (1982) · Diabetes Care · doi:10.2337/diacare.5.2.77 · Cited by 252
Galloway, J. A., Spradlin, C. T., Nelson, R. L., Wentworth, S. M., Davidson, J. A., & Swarner, J. L. (1981) · Diabetes Care · doi:10.2337/diacare.4.3.366 · Cited by 226
Patton, J. S., Bukar, J., & Nagarajan, S. (1999) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00074-x · Cited by 193
Inadequate suspension of neutral protamine Hagendorn (NPH) insulin in pens
Jehle, P. M., Micheler, C., Jehle, D. R., Breitig, D., & Boehm, B. O. (1999) · The Lancet · doi:10.1016/s0140-6736(98)12459-5 · Cited by 186
Heinemann, L., Weyer, C., Rauhaus, M., Heinrichs, S., & Heise, T. (1998) · Diabetes Care · doi:10.2337/diacare.21.11.1910 · Cited by 163
Self-citationTime‐action profile of the soluble, fatty acid acylated, long‐acting insulin analogue NN304
Heinemann, L., Sinha, K., Weyer, C., Loftager, M., Hirschberger, S., & Heise, T. (1999) · Diabetic Medicine · doi:10.1046/j.1464-5491.1999.00081.x · Cited by 158
Self-citationDanne, T., Lüpke, K., Walte, K., von Schuetz, W., & Gall, M.-A. (2003) · Diabetes Care · doi:10.2337/diacare.26.11.3087 · Cited by 153
Research works printed but not linked: 6
- Antsiferov M, 1995, Diabetologia, 38, 733
- Galloway JA, 1986, Amsterdam: Excerpta Medica, 877
- Scholtz HE, 1999, Diabetologia, 42, A235
- Perea AD, 2001, Diabetologia, 44, A212
- Strange P, 1999, Diabetes, 8, A103
- Vignati L, 1995, Diabetologia, 38, 737
Cited by
Items 101–200 of 300
Safety and side effects of the insulin analogues
Kamal, A. D., Dixon, A., & Bain, S. C. (2005) · Expert Opinion on Drug Safety · doi:10.1517/14740338.5.1.131 · Cited by 28
Clausen, W. H. O., Gaetano, A. D., & Vølund, A. (2006) · Diabetologia · doi:10.1007/s00125-006-0327-z · Cited by 27
Weight gain and insulin therapy
Khan, R. (2004) · The British Journal of Diabetes · doi:10.1177/14746514040040040901 · Cited by 27
Dynamic flux balance analysis of whole-body metabolism for type 1 diabetes
Guebila, M. B., & Thiele, I. (2021) · Nature Computational Science · doi:10.1038/s43588-021-00074-3 · Cited by 26
Renard, É., Dubois‐Laforgue, D., Guerci, B., & Study, O. B. O. T. V. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0063 · Cited by 26
The Impact of Non–Model-Related Variability on Blood Glucose Prediction
Kildegaard, J., Randløv, J., Poulsen, J. U., & Hejlesen, O. K. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.0039 · Cited by 27
Fathi, A. E., Kearney, R. E., Palisaitis, E., Boulet, B., & Haidar, A. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3023555 · Cited by 25
Pechenov, S., Bhattacharjee, H., Yin, D., Mittal, S., & Subramony, J. A. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.01.006 · Cited by 25
How to achieve a predictable basal insulin?
Kurtzhals, P. (2005) · Diabetes & Metabolism · doi:10.1016/s1262-3636(05)88264-3 · Cited by 25
Assessment of the Mixing Efficiency of Neutral Protamine Hagedorn Cartridges
Kaiser, P., Maxeiner, S., Weise, A., Nolden, F., Borck, A., Forst, T. M., & Pfützner, A. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400320 · Cited by 24
Al‐Qaissi, A., Papageorgiou, M., Javed, Z., Heise, T., Rigby, A. S., Garrett, A. T., Hepburn, D. A., Kilpatrick, E. S., Atkin, S. L., & Sathyapalan, T. (2018) · Diabetes Obesity and Metabolism · doi:10.1111/dom.13555 · Cited by 24
Dietary carbohydrate intake and cardio-metabolic risk factors in type 1 diabetes
Ahola, A. J., Forsblom, C. M., Harjutsalo, V., & Groop, P. (2019) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2019.107818 · Cited by 25
A second-generation inhaled insulin for diabetes mellitus
Ledet, G. A., Graves, R. A., Bostanian, L. A., & Mandal, T. K. (2015) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp140540 · Cited by 24
Molecular variants and derivatives of insulin for improved glycemic control in diabetes
Bhatnagar, S., Srivastava, D., Jayadev, M. S. K., & Dubey, A. K. (2005) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2005.05.012 · Cited by 24
Sources of Glycemic Variability—What Type of Technology is Needed?
Kildegaard, J., Christensen, T. F., & Hejlesen, O. K. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300448 · Cited by 24
(2018) · doi:10.1177/1932296817735341 · Cited by 23
“Two scenarios were modeled independently after 1 hour of simulated time: (1) basal insulin infusion rates in increments of 0.”
MethodAre Glucose Readings Sufficient to Adjust Insulin Dosage?
Bashan, E., Herman, W. H., & Hodish, I. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0112 · Cited by 22
Roe, E. D., Chamarthi, B., & Raskin, P. (2015) · Journal of Diabetes Research · doi:10.1155/2015/834903 · Cited by 22
Insulin related lipodystrophic lesions and hypoglycemia: Double standards?
Gentile, S., Strollo, F., Corte, T. D., Marino, G., & Guarino, G. (2018) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2018.04.023 · Cited by 22
Pharmacokinetic and Pharmacodynamic Variability of Insulin When Administered by Jet Injection
Engwerda, E. E. C., Tack, C. J., & de Galan, B. E. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817699638 · Cited by 22
Low-carbohydrate diet in diabetes mellitus treatment
Krejčí, H., Vyjídák, J., & Kohutiar, M. (2018) · Vnitřní lékařství · doi:10.36290/vnl.2018.102 · Cited by 23
Towards in vitro in vivo correlation for modified release subcutaneously administered insulins
Bock, F., Lin, E., Larsen, C., Jensen, H. M., Huus, K., Larsen, S. W., & Østergaard, J. (2020) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2020.105239 · Cited by 21
Subcutaneous Drug Delivery: A Review of the State-of-the-Art Modeling and Experimental Techniques
Sharma, P., Gajula, K., Dingari, N. N., Gupta, R. K., Gopal, S., Rai, B., & Iacocca, R. G. (2022) · Journal of Biomechanical Engineering · doi:10.1115/1.4055758 · Cited by 21
Spellman, C. (2009) · PubMed · Cited by 23
Friedberg, S. J., Lam, Y.-W. F., Blum, J. J., & Gregerman, R. I. (2006) · Metabolism · doi:10.1016/j.metabol.2005.12.004 · Cited by 21
Zisser, H. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500537 · Cited by 21
The effort required to achieve and maintain optimal glycemic control
Rosenthal, E. S., Bashan, E., Herman, W. H., & Hodish, I. (2011) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2011.01.002 · Cited by 20
Subcutaneous Insulin Administration: Sufficient Progress or Ongoing Need?
Pettis, R. J., Muchmore, D. B., & Heinemann, L. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818817011 · Cited by 20
Self-citationLaimer, M. W., Melmer, A., Mader, J. K., Schütz-Fuhrmann, I., Engels, H.-R., Götz, G., Pfeifer, M., Hermann, J. M., Stettler, C., & Holl, R. W. (2016) · PLoS ONE · doi:10.1371/journal.pone.0150604 · Cited by 19
Ahola, A. J., Harjutsalo, V., Forsblom, C. M., Saraheimo, M., Groop, P., & Study, O. B. O. T. F. D. N. (2018) · Diabetic Medicine · doi:10.1111/dme.13863 · Cited by 19
Advanced carbohydrate counting: An engineering perspective
Reiterer, F., & Freckmann, G. (2019) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2019.06.003 · Cited by 19
Palisaitis, E., Fathi, A. E., Oettingen, J. E. V., Krishnamoorthy, P., Kearney, R. E., Jacobs, P. G., Rutkowski, J., Legault, L., & Haidar, A. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0270 · Cited by 19
Levy, P. (2007) · PubMed Central · Cited by 19
Diabetes - Damages and Treatments
Rigobelo, E. C. (2011) · InTech eBooks · doi:10.5772/1823 · Cited by 17
Paediatric diabetes: achieving practical, effective insulin therapy in type 1 and type 2 diabetes
Danne, T., & BECKER, D. J. (2007) · Acta Paediatrica · doi:10.1111/j.1651-2227.2007.00494.x · Cited by 17
de la Fuente, J. S., Berná, V. G., Piquero, J. M. F., Zanuy, M. Á. V., & López-Coterilla, A. H. D. T. (2008) · Revista Clínica Española · doi:10.1157/13115203 · Cited by 16
Joshi, S., Jayanth, V., Loganathan, S., Sambandamurthy, V. K., & Athalye, S. N. (2023) · Drugs · doi:10.1007/s40265-023-01925-1 · Cited by 16
Fathi, A. E., Palisaitis, E., Oettingen, J. E. V., Krishnamoorthy, P., Kearney, R. E., Legault, L., & Haidar, A. (2020) · Pediatric Diabetes · doi:10.1111/pedi.13052 · Cited by 16
Schneider, S., Biggerstaff, D. L., & Barber, T. M. (2022) · Expert Review of Endocrinology & Metabolism · doi:10.1080/17446651.2022.2089112 · Cited by 16
Faggionato, E., Schiavon, M., & Dalla Man, C. (2021) · Metabolites · doi:10.3390/metabo11040235 · Cited by 15
“In fact, subcutaneous injections of the same exact insulin dose may greatly differ between different individuals or even in the same individual on different occasions [1].”
BackgroundSala-Mira, I., Díez, J.-L., & Bondía, J. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.1153 · Cited by 15
Feasibility study of a prototype extended‐wear insulin infusion set in adults with type 1 diabetes
Kastner, J. R., Venkatesh, N., Brown, K., Muchmore, D. B., Ekinci, E. I., Fourlanos, S., Joseph, J. I., Shafeeq, M., Shi, L., Strange, P., et al. (2022) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14685 · Cited by 15
Insulin detemir: improving the predictability of glycaemic control
Russell-Jones, D. L. (2004) · International Journal of Obesity · doi:10.1038/sj.ijo.0802747 · Cited by 15
Insulin degludec in J apanese patients with type 1 diabetes mellitus: A randomized controlled trial
Iwamoto, Y., Clauson, P., Nishida, T., & Kaku, K. (2012) · Journal of Diabetes Investigation · doi:10.1111/j.2040-1124.2012.00240.x · Cited by 14
Unconventional insulins from predators and pathogens
Laugesen, S. H., Chou, D. H., & Safavi-Hemami, H. (2022) · Nature Chemical Biology · doi:10.1038/s41589-022-01068-6 · Cited by 13
McKiel, L. A., Ballantyne, L. L., Negri, G. L., Woodhouse, K. A., & Fitzpatrick, L. E. (2023) · Frontiers in Immunology · doi:10.3389/fimmu.2023.1232586 · Cited by 13
Chauhan, S., Jhawat, V., Singh, R. P., & Yadav, A. (2024) · Burns · doi:10.1016/j.burns.2024.01.008 · Cited by 13
Reiterer, F., Kirchsteiger, H., Assalone, A., Freckmann, G., & del Re, L. (2015) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2015.10.144 · Cited by 13
Lv, D., Kulkarni, S. D., Chan, A., Keith, S., Pettis, R. J., Kovatchev, B. P., Farhy, L. S., & Breton, M. D. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815573864 · Cited by 12
Jaramillo, G., & Alejandra, M. (2011) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 12
Kobayati, A., Fathi, A. E., Garfield, N., Legault, L., Jafar, A., Yale, J., Tsoukas, M. A., & Haidar, A. (2025) · Nature Communications · doi:10.1038/s41467-025-63671-0 · Cited by 11
Landau, Z., Klonoff, D. C., Nayberg, I., Feldman, D., Levit, S., Lender, D., Mosenzon, O., Raz, I., & Wainstein, J. (2014) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.2536 · Cited by 11
Robust tube-based predictive control of blood glucose concentration in type 1 diabetes
Kirchsteiger, H., & del Re, L. (2013) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2013.6760189 · Cited by 11
Misled by the Morning “Fasting” Plasma Glucose
King, A. B. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815586425 · Cited by 9
Artificial Pancreas Control for Diabetes using TD3 Deep Reinforcement Learning
Mackey, A., & Furey, E. (2022) · Irish Signals and Systems Conference · doi:10.1109/issc55427.2022.9826219 · Cited by 9
Bashan, E., & Hodish, I. (2012) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2012.03.012 · Cited by 9
Insulinothérapie Nouvelles molécules et voies d’administration
Verge, D. (2004) · médecine/sciences · doi:10.1051/medsci/20042011986 · Cited by 9
Model-Based Decision Support in Glycaemic Control
Fisk, L. (2014) · UC Research Repository (University of Canterbury) · doi:10.26021/3288 · Cited by 9
Newer Insulin Preparations and Insulin Analogs
Tiwari, D. D., Thorat, V. M., & Pakale, P. V. (2024) · Cureus · doi:10.7759/cureus.74593 · Cited by 8
Rodríguez-Almeida, A. J., Acosta, C. B., Wägner, A. M., Callicó, G. M., & Fabelo, H. A. (2025) · Sensors · doi:10.3390/s25154647 · Cited by 9
Niazi, S. K. (2026) · Frontiers in Drug Delivery · doi:10.3389/fddev.2026.1776167 · Cited by 8
Fathi, A. E., & Breton, M. D. (2023) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2023.10.446 · Cited by 8
Li, T., Liu, H., Yu, H., Qiao, J., Sun, L., & Yu, Y. (2021) · Clinical Therapeutics · doi:10.1016/j.clinthera.2021.01.008 · Cited by 8
Dietary strategies for adult type 1 diabetes in light of outcome evidence
Matteucci, E., & Giampietro, O. (2014) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2014.214 · Cited by 8
Raz, I., Bitton, G., Feldman, D., Tal, A., Pfützner, A., & Tamborlane, W. V. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815578881 · Cited by 8
The potential effect of ultra-long insulin degludec on glycemic variability
Rodacki, M., Carvalho, R. M., & Zajdenverg, L. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.06.003 · Cited by 9
(2008) · Clinical Governance An International Journal · doi:10.1108/cgij.2008.24813bae.003 · Cited by 8
Model-Based Therapeutics for Type 1 Diabetes Mellitus
Wong, X. (2008) · UC Research Repository (University of Canterbury) · doi:10.26021/1222 · Cited by 8
Rattananukrom, T., Tejapira, K., Pomsoong, C., Ratanapokasatit, Y., & Vachiramon, V. (2025) · Journal of Cosmetic Dermatology · doi:10.1111/jocd.70033 · Cited by 7
Tucker, A. P., Erdman, A. G., Schreiner, P. J., Ma, S., & Chow, L. S. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221100839 · Cited by 7
Furió-Novejarque, C., Sanz, R., Ritschel, T. K. S., Reenberg, A. T., Ranjan, A. G., Nørgaard, K., Díez, J.-L., Jørgensen, J. B., & Bondía, J. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.106605 · Cited by 7
Examining Sensor Agreement in Neural Network Blood Glucose Prediction
Tucker, A. P., Erdman, A. G., Schreiner, P. J., Ma, S., & Chow, L. S. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211018246 · Cited by 7
Bibal, C., Rothenbühler, A., Lucchini, P., Aboumrad, B., Castell, A., Fur, S. L., & Bougneres, P. F. (2014) · Pediatric Diabetes · doi:10.1111/pedi.12156 · Cited by 7
Scheen, A. J., Radermecker, R. P., Philips, J. C., & Paquot, N. (2005) · PubMed · Cited by 7
Closed-loop insulin delivery in adults with type 1 diabetes
Kumareswaran, K. (2012) · Apollo (University of Cambridge) · doi:10.17863/cam.16644 · Cited by 7
Steyn, L. V., Drew, D. A., Vlachos, D., Huey, B., Cocchi, K., Price, N. D., Johnson, R., Putnam, C. W., & Papas, K. K. (2023) · PLoS ONE · doi:10.1371/journal.pone.0278794 · Cited by 6
The RapidMist™ System for Buccal Delivery of Insulin
Bansal, M., Bansal, S. K., & Kumria, R. (2014) · Springer eBooks · doi:10.1007/978-1-4614-9524-6_19 · Cited by 6
Artificial pancreas: the bridge to a cure for type 1 diabetes
Thabit, H., Hovorka, R., & Evans, M. L. (2012) · European Diabetes Nursing · doi:10.1002/edn.207 · Cited by 6
Coales, E., Ajjan, R., Pearson, S. M., O’Mahoney, L. L., Kietsiriroje, N., Brož, J., Holmes, M. J., & Campbell, M. D. (2021) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2021.09.002 · Cited by 6
Wong, X., Chase, J. G., Compte, A. J. L., Hann, C. E., Lin, J., & Shaw, G. M. (2008) · International Journal of Adaptive Control and Signal Processing · doi:10.1002/acs.1069 · Cited by 6
Hitting the Dartboard from 40,000 Feet
Hirsch, I. B. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0190 · Cited by 6
Automated optimal glycaemic control using a physiology based pharmacokinetic, pharmacodynamic model
Schaller, S., Schuppert, A., & Mitsos, A. (2015) · RWTH Publications (RWTH Aachen) · Cited by 6
Roszmann, A., Piekarski, R., Mongird-Niklewski, P., & Sławek, J. W. (2025) · Neurologia i Neurochirurgia Polska · doi:10.5603/pjnns.108714 · Cited by 5
Assessment of a new model of glucagon action with glucagon receptor dynamics
Furió-Novejarque, C., Sanz, R., Reenberg, A. T., Ritschel, T. K. S., Ranjan, A. G., Nørgaard, K., Díez, J.-L., Jørgensen, J. B., & Bondía, J. (2022) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2022.09.169 · Cited by 5
Enhancing Glucose Sensor Models: Modeling the Drop-Outs
Emami, A., RABASA-LHORET, R. P. R., & Haidar, A. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0309 · Cited by 5
Detemir (Levemir): modern paradigms of insulin therapy
Руяткина, Л. А., & Sorokin, M. (2013) · Problems of Endocrinology · doi:10.14341/probl201359456-64 · Cited by 5
Predicting Nocturnal Hypoglycemia Using a Non-parametric Insulin Action Model
Ståhl, F. L., Johansson, R., & Olsson, M. L. (2015) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2015.280 · Cited by 5
Inhaled insulin in diabetes mellitus
Royle, P., Waugh, N. R., Deakin, M., & Philip, S. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003890.pub3 · Cited by 5
Gradel, A. K. J., Porsgaard, T., Lykkesfeldt, J., Brockhoff, P. B., Seested, T., & Refsgaard, H. H. F. (2018) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/a-0658-1089 · Cited by 5
Absorption Kinetics of Insulin Mixtures after Subcutaneous Administration
Rasmussen, C. H., Søeborg, T., Mosekilde, E., & Colding‐Jørgensen, M. (2011) · Springer eBooks · doi:10.1007/978-3-7091-0418-7_15 · Cited by 5
The role of insulin detemir in overweight type 2 diabetes management
Soran, H. (2009) · Vascular Health and Risk Management · doi:10.2147/vhrm.s4326 · Cited by 5
Can technological solutions for diabetes replace islet cell function?
Gregory, J. M., & Moore, D. J. (2011) · Organogenesis · doi:10.4161/org.7.1.14028 · Cited by 5
Sensitivity analysis for a delay mathematical model: the glucose-insulin model
Bachar, M. (2025) · Frontiers in Applied Mathematics and Statistics · doi:10.3389/fams.2025.1562636 · Cited by 4
Intensifying Treatment of Type 2 Diabetes Mellitus: Adding Insulin
Peters, K. R. (2011) · Pharmacotherapy The Journal of Human Pharmacology and Drug Therapy · doi:10.1592/phco.31.12.54s · Cited by 4
Human insulin versus porcine insulin in rhesus monkeys with diabetes mellitus
Jin, X., Zeng, L., Zhang, S., He, S., Ren, Y., Chen, Y., Wei, L., Wang, L., Li, H., Cheng, J., et al. (2012) · Journal of Medical Primatology · doi:10.1111/jmp.12025 · Cited by 4
Bell, E., Binkowski, S., Sanderson, E., Keating, B., Smith, G. J., Harray, A. J., & Davis, E. A. (2021) · Nutrients · doi:10.3390/nu13114154 · Cited by 4
A mechanistic modeling platform of SGLT2 inhibition: Implications for type 1 diabetes
Sokolov, V., Yakovleva, T. A., Stolbov, L. A., Penland, R. C., Boulton, D. W., PARKINSON, J. R., & Tang, W. (2023) · CPT Pharmacometrics & Systems Pharmacology · doi:10.1002/psp4.12956 · Cited by 4
Georga, E. I., Fotiadis, D. I., & Tigas, S. K. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804831-3.00001-7 · Cited by 4
Inhaled Insulin: Take a Deep Breath, but How?
Heinemann, L., Scheuch, G., & Heise, T. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200222 · Cited by 4
Self-citationDiabetes and Disability: Medical, Social, and Legal Perspectives
Sen, A., Saxena, I., & Kaur, A. P. (2024) · Springer eBooks · doi:10.1007/978-3-031-40858-8_378-1 · Cited by 4
Metadata
- Authors
- Heinemann, L.
- Affiliations
- Profil Institute for Metabolic Research (DE)
- Corresponding author
- Heinemann, Lutz
- ORCID
- Heinemann, Lutz
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2002-10
- Volume
- 4
- Issue
- 5
- Pages
- 673-682
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2008449957
- Cited by
- 267
- References
- 26
- Citations by year
- 2026: 9 · 2025: 10 · 2024: 6 · 2023: 12 · 2022: 12 · 2021: 12 · 2020: 10 · 2019: 7 · 2018: 9 · 2017: 15 · 2016: 6 · 2015: 17 · 2014: 11 · 2013: 6 · 2012: 21
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.liebertpub.com/nv/resources-tools/text-and-data-mining-policy/121/ (tdm)
- Locations
- Diabetes Technology & Therapeutics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- insulin action, insulin absorption, subcutaneous insulin administration, pulmonary insulin delivery, insulin analogues, NPH insulin, long-acting insulin, type 1 diabetes, type 2 diabetes, glucose clamp, coefficient of variation, interindividual variability, within-person variability, insulin pharmacodynamics, insulin therapy, dose-response relationship, glycemic control
- MeSH terms
- Administration, Inhalation, Blood Glucose, Diabetes Mellitus, Humans, Injections, Subcutaneous, Insulin, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.