Precipitation of Insulin Products Used for Continuous Subcutaneous Insulin Infusion
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Commercially available insulin products used for continuous subcutaneous insulin infusion have been compared with respect to resistance towards isoelectric insulin precipitation. METHODS: The degree of isoelectric insulin precipitation of insulin aspart injection (IAsp), insulin lispro injection (ILis), and buffered human regular insulin injection (BHR) was examined while reducing pH through addition of diluted HCl or exposure to CO2. RESULTS: The pH at which defined fractions of the insulins precipitated differed among the three products; 10% and 90% precipitation, respectively, was observed at pH 6.41 and pH 6.30 for ILis, pH 6.18 and pH 5.95 for BHR, and pH 5.90 and pH 5.67 for IAsp, in accordance with the isoelectric points of these insulin species. The amount of H(+)-equivalents per microliter of product to reach 10% precipitation was found to be highest for IAsp (5.49 nmol of H(+)-equivalents), with ILis and BHR almost equivalent to each other (4.46 and 4.32 nmol of H(+)-equivalents, respectively). Exposure to a CO2-enriched environment resulted in the same order of insulin precipitation of the three products as tested with HCl. CONCLUSIONS: Resistance towards isoelectric precipitation is highest for IAsp, lowest for ILis, and intermediate for BHR. Isoelectric precipitation will alter the pharmacokinetic properties of the insulin and could lead to occlusion of the infusion catheter, causing elevated blood glucose and ultimately causing diabetic ketoacidosis if no intervention is made. Causal relationships between the observed differences in resistance towards isoelectric precipitation of the insulin products, the mechanism behind catheter occlusion, and the clinical relevance of the observations require further studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bode, B. W., Steed, R. D., & Davidson, P. C. (1996) · Diabetes Care · doi:10.2337/diacare.19.4.324 · Cited by 257
Safety and effectiveness of insulin pump therapy in children and adolescents with type 1 diabetes
Plotnick, L. P., Clark, L. M., Brancati, F. L., & Erlinger, T. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1142 · Cited by 216
Bode, B., Weinstein, R., Bell, D., McGill, J., Nadeau, D., Raskin, P., Davidson, J., Henry, R., Huang, W.-C., & Reinhardt, R. R. (2002) · Diabetes Care · doi:10.2337/diacare.25.3.439 · Cited by 148
Cited by
Insulin Infusion Set: The Achilles Heel of Continuous Subcutaneous Insulin Infusion
Heinemann, L., & Krinelke, L. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600429 · Cited by 153
Schmid, V., Hohberg, C., Borchert, M., Forst, T., & Pfützner, A. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400429 · Cited by 97
Bode, B. W. (2011) · Endocrine Practice · doi:10.4158/ep10260.ra · Cited by 56
Pfützner, A., Sachsenheimer, D., Grenningloh, M., Heschel, M., Walther-Johannesen, L., Gharabli, R., & Klonoff, D. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815604438 · Cited by 53
Metadata
- Authors
- Poulsen, C., Langkjær, L., & Worsøe, C.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2005-02
- Volume
- 7
- Issue
- 1
- Pages
- 142-150
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2065565878
- Cited by
- 37
- References
- 3
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.