CoChat

Relationship Between Interstitial And Blood Glucose in Type 1 Diabetes Patients: Delay And The Push-Pull Phenomenon Revisited

Wentholt, Iris M.E., Hart, Augustus A.M., Hoekstra, Joost B.L., Devries, J. Hans · 2007 · Diabetes Technology & Therapeutics
Cited by 54

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Interpretation of glucose sensor results requires clarification of the relationship between interstitial (IG) and blood (BG) glucose. We examined the delay of IG upon BG change and reinvestigated the push-pull phenomenon in type 1 diabetes patients. The push-pull phenomenon postulates that IG shows a delayed increase but earlier decrease compared to BG. If so, postprandial sensor curves should have narrower peak widths than BG curves. METHODS: For both sensors a two-point calibration procedure was used. Delay was assessed by shifting combined fitted postprandial glucose sensor curves horizontally. The sensor and BG peak widths of the separately fitted curves were assessed and compared. Peak width was re-assessed for the microdialysis sensor using raw current values to rule out any calibration effect on the shape of the curve. The contribution of instrumental delay to the earlier reported 7.1-min delay of the microdialysis sensor was calculated. RESULTS: No delay [-2.2 +/- 6.2 (SD) min] was seen for the needle-type sensor. Instrumental delay was >6.2 min for the microdialysis sensor, accounting for more than 87% of the total reported delay of 7.1 +/- 5.5 min. Mean peak width for the BG curves was 100.8 +/- 25.0 min, for the needle-type sensor curves 110.0 +/- 20.5 min, and for the microdialysis sensor curves 104.6 +/- 21.7 min (P = 0.052 and P = 0.11 vs. BG, respectively). Mean peak width for the uncalibrated microdialysis current values was 105.0 +/- 23.1 min, which was not different from the peak width of the BG curves (P = 0.347). CONCLUSIONS: IG-BG delay may be smaller than previously postulated. The sensor curves tended to have broader peaks than the BG curves, in contrast to the expected narrower peaks predicted by the push-pull phenomenon. This argues against the existence of the push-pull phenomenon.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2006.0007

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 54

Metadata

Authors
Wentholt, I. M. E., Hart, A. A. M., Hoekstra, J. B. L., & Devries, J. H.
Venue
Diabetes Technology & Therapeutics
Published
2007-04
Volume
9
Issue
2
Pages
169-175
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2075424907
Cited by
54
References
2
FWCI
4.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Relationship Between Interstitial And Blood Glucose in Type 1 Diabetes Patients: Delay And The Push-Pull Phenomenon Revisited. https://app.cochat.ai/papers/10.1089/dia.2006.0007
The paper
Wentholt, I. M. E., Hart, A. A. M., Hoekstra, J. B. L., & Devries, J. H. (2007). Relationship Between Interstitial And Blood Glucose in Type 1 Diabetes Patients: Delay And The Push-Pull Phenomenon Revisited. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2006.0007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.