BACKGROUND: This study was designed to assess clinical performance and patients' acceptance of the minimally invasive microdialysis-based continuous glucose monitoring system Gluco- Day() (Menarini Diagnostics, Florence, Italy) with a targeted monitoring time of 48 h. METHODS: An inpatient sample of 28 patients with diabetes was studied. The analysis of clinical performance was performed using mean absolute differences (MAD) (in percent), Pearson correlations, the Bland-Altman analysis, and Clarke Error Grid Analysis (EGA). GlucoDay glucose values were compared with laboratory standard blood glucose measurements (glucohexokinase assay). The patients' acceptance of the monitoring device was assessed via two self-report scales (pain during application and discomfort while wearing device). RESULTS: A mean (+/- SD) monitoring time of 45.7 +/- 3.3 h with a total of 484 paired readings could be achieved. A correlation of r (average) = 0.91 and a MAD of 19.9% indicated satisfactory to good clinical performance. Of the paired readings, 95.5% fell into the acceptable A and B zones of the EGA. Rather wide 95% limits of agreement were revealed in the Bland-Altman analysis. Whereas virtually no pain was experienced during sensor application, discomfort associated with wearing the device was rather high. All of the participants, however, stated that they would wear the device again. CONCLUSIONS: Satisfactory to good performance of the GlucoDay monitor was observed, indicating the device to be suitable for routine clinical use. In particular, however, the discomfort experienced during wearing requires further improvements in its usability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2006.8.570

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 37

Metadata

Authors
Kubiak, T., Wörle, B., Kuhr, B., Nied, I., Gläsner, G., Hermanns, N., Kulzer, B., & Haak, T.
Venue
Diabetes Technology & Therapeutics
Published
2006-10
Volume
8
Issue
5
Pages
570-575
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2008406255
Cited by
37
References
2
FWCI
2.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.