Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 164

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Bolus Calculator: A Review of Four “Smart” Insulin Pumps

Zisser, Howard, Robinson, Lauren, Bevier, Wendy, Dassau, Eyal, Ellingsen, Christian, Doyle, Francis J., Jovanovic, Lois · 2008 · Diabetes Technology & Therapeutics

Abstract

The use of continuous subcutaneous insulin infusion (CSII) pumps has been gaining popularity since 1979, when the first research report on insulin pumps was published. Insulin pumps-small medical devices that are programmed to infuse insulin through a catheter placed under the skin-are a replacement for multiple daily injections of insulin. They are currently being used by 375,000 people with type 1 diabetes, many of whom prefer CSII to multiple daily injections because of the increased flexibility of diet and exercise, increased convenience and precision when dosing, and better predictability of blood glucose levels that insulin pumps can provide when used correctly. Recent pump manufacturers have engineered a new feature called a bolus calculator, which calculates bolus insulin doses based on input from the pump wearer, which functions to help patients obtain optimum control over blood glucose levels. The bolus calculator takes into account the patient's current blood glucose, target blood glucose, amount of carbohydrate consumed, and other factors such as insulin sensitivity and insulin-to-carbohydrate ratio as well as duration of insulin action ("insulin on board"). Each pump company calculates insulin doses in a slightly different way. This article will review differences in bolus calculator recommendations between four insulin pumps, as well as errors that may occur when using bolus calculators. It will also include an in silico simulation of a meal followed by a snack using multiple insulin decay curves.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2007.0284

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 3

  1. 10.1089/152091503765691848 · DOI
  2. 10.2337/diacare.21.11.1910 · DOI · Paper page
  3. 10.2337/diacare.11.10.769 · DOI

Cited by

See all 164

Metadata

Authors
Zisser, H., Robinson, L., Bevier, W., Dassau, E., Ellingsen, C., Doyle, F. J., & Jovanovic, L.
Venue
Diabetes Technology & Therapeutics
Published
2008-12
Volume
10
Issue
6
Pages
441-444
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W1999128357
Cited by
164
References
1
FWCI
7.41
Type
journal article
Language
en
Open access
closed
Licence
www.liebertpub.com/nv/resources-tools/text-and-data-mining-policy/121/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bolus Calculator: A Review of Four “Smart” Insulin Pumps. https://app.cochat.ai/papers/10.1089/dia.2007.0284
The paper
Zisser, H., Robinson, L., Bevier, W., Dassau, E., Ellingsen, C., Doyle, F. J., & Jovanovic, L. (2008). Bolus Calculator: A Review of Four “Smart” Insulin Pumps. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2007.0284

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.