Standardized Evaluation of Nine Instruments for Self-Monitoring of Blood Glucose
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Instruments for self-monitoring of blood glucose (SMBG) should undergo a standardized evaluation including a user-test before being marketed. In this study the results from standardized evaluations of nine different SMBG instruments are presented, and the standardized evaluation is discussed. METHODS: Approximately 80 diabetes patients using three lots of test strips participated in each evaluation. Half of the patients were educated in how to use the meter, and the evaluations were carried out by both medical laboratory technologists (MLTs) and patients. Questionnaires were used to assess the user manual and the user-friendliness of the instrument. RESULTS: The imprecision obtained by the patients (coefficients of variation [CVs] of 3.2-8.1%) were generally higher compared to that by the MLT (CVs of 2.3-5.9%). Three of the nine instruments did not achieve the quality goal based on the recommendation in the International Organization for Standardization's ISO 15197 guideline in the hands of diabetes patients. The bias from the comparison method ranged from -10.4% to +3.2%. There were significant lot-to-lot variations and hematocrit effects for some of the instruments. Temperature difference between the instruments and the test strip caused deterioration of the quality in one instrument. The user-friendliness was in general acceptable. CONCLUSIONS: The quality of instruments for SMBG seems to have improved during recent years, although there are still analytical problems. A standardized evaluation protocol is necessary and should be regularly revised taking into account the development of new technology and the needs of the patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Global guideline for type 2 diabetes
(2014) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2012.10.001 · Cited by 1,064
Goldstein, D. E., Little, R. R., Lorenz, R. A., Malone, J. I., Nathan, D., Peterson, C. M., & Sacks, D. B. (2004) · Diabetes Care · doi:10.2337/diacare.27.7.1761 · Cited by 625 · cited 1×
“26 For two of the instruments in this study the participants who received training obtained a significant better CV compared to the group without training, whereas for one instrument, the OneTouch Ultra, the CV was poorer in the trained group.”
Farmer, A., Wade, A., Goyder, E., Yudkin, P., French, D., Craven, A., Holman, R., Kinmonth, A.-L., & Neil, A. (2007) · BMJ · doi:10.1136/bmj.39247.447431.be · Cited by 407
Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin
Malanda, U. L., Welschen, L. M., Riphagen, I. I., Dekker, J. M., Nijpels, G., & Bot, S. D. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005060.pub3 · Cited by 358
Tang, Z., Lee, J. H., Louie, R. F., & Kost, G. J. (2000) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2000-124-1135-eodhlo · Cited by 293
Skeie, S., Thue, G., Nerhus, K., & Sandberg, S. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.7.994 · Cited by 131 · cited 3×
“12 29 Hematocrit may critically influence the SMBG re-sults.”
Self-citationKristensen, G. B. B., Nerhus, K., Thue, G., & Sandberg, S. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.031575 · Cited by 68
Self-citationEvolution of analytical performance in portable glucose meters in the last decade
Böhme, P., Floriot, M., Sirveaux, M.-A., Durain, D., Ziegler, O., Drouin, P., & Guerci, B. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1170 · Cited by 51
Assessing the quality of glucose monitor studies: a critical evaluation of published reports
Mahoney, J., & Ellison, J. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.083493 · Cited by 48
Balion, C., Grey, V., Ismaila, A., Blatz, S., & Seidlitz, W. (2006) · BMC Pediatrics · doi:10.1186/1471-2431-6-28 · Cited by 46 · cited 1×
“30,31 Even if the manufacturer declared that no hematocrit effects were present in the measurement range of the evaluated instruments, an effect was found for five of the instruments.”
Cited by
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Use of multiple colorimetric indicators for paper-based microfluidic devices
Dungchai, W., Chailapakul, O., & Henry, C. S. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.06.019 · Cited by 364
Freckmann, G., Schmid, C., Baumstark, A., Pleus, S., Link, M., & Haug, C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600510 · Cited by 237
Freckmann, G., Schmid, C., Baumstark, A., Rutschmann, M., Haug, C., & Heinemann, L. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815580160 · Cited by 70
Freckmann, G., Link, M., Schmid, C., Pleus, S., Baumstark, A., & Haug, C. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0085 · Cited by 46
Metadata
- Authors
- Kristensen, G. B. B., Monsen, G., Skeie, S., & Sandberg, S.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2008-12
- Volume
- 10
- Issue
- 6
- Pages
- 467-477
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2077092163
- Cited by
- 56
- References
- 11
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.