Lower Rate of Initial Failures and Reduced Occurrence of Adverse Events with a New Catheter Model for Continuous Subcutaneous Insulin Infusion: Prospective, Two-Period, Observational, Multicenter Study

Renard, Eric, Guerci, Bruno, Leguerrier, Anne-Marie, Boizel, Robert·2010·Diabetes Technology & Therapeutics

Abstract

Background: No recent clinical data on the incidence of catheter-related adverse events under insulin pump therapy have been reported. Methods: This was a prospective, two-period, observational, multicenter study in 45 diabetes outpatients (mean continuous subcutaneous insulin infusion [CSII] use, 6 years; mean hemoglobin A1c, 7.7%, at baseline). During the initial 1-month period (P1), the patients used their current catheter model, including a soft cannula in 98% of cases. They moved then to the new Accu-Chek ® FlexLink catheter model (Disetronic Medical Systems AG, Burgdorf, Switzerland) for a 3-month period. The primary end point, including insertion failures and unexplained hyperglycemia within the first 6 h after catheter placement, was assessed from logbook records during P1 and the last month of the second period (P2). Secondary end points were catheter replacements for unexplained hyperglycemia and/or events at risk for immediate insulin delivery failure after the first 6 h. Results: Forty-five initial infusion failures occurred in 14 patients among 507 catheter insertions (8.9% of cases) during P1, whereas 15 similar events were seen in nine patients during P2 among 488 catheter insertions (3.1% of cases) ( P < 0.001). Catheters were replaced for later infusion troubles in 8% of cases during both P1 and P2. The overall rate of late cumulative events was, however, 113 of 507 (P1) versus 66 of 488 (P2) ( P < 0.001). The occurrence of pain, skin reaction, or redness at the infusion site was lower during P2. Conclusion: Incidences both of initial failures and of premature catheter replacements were 8–9% with current CSII catheters. Significantly reduced failures after insertion and adverse events at the infusion site were observed with the new catheter model.

Integrity signals

Registry

Crossref · 10.1089/dia.2010.0073

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Silent occlusions contribute to the occurrence of unexplained hyperglycemia and glycemic variability in patients using CSII.

    “Based on our findings as well as previous reports,15,16,18 we believe that silent occlusions contribute to the occurrence of unexplained hyperglycemia and glycemic variability in patients using CSII.”
  • A 15% failure rate of polymer catheters over the 8-h period following insertion was observed by Patel et al., and nearly 9% of soft cannula insertions failed within a 6-h period by Renard et al.

    “Furthermore, a 15% failure rate of polymer catheters (blood glucose value of >250 mg/dL and not decreasing at least 50 mg in 1 h post–correction bolus) over the 8-h period following insertion was observed by Patel et al.15 and in nearly 9% of soft cannula insertions within a 6-h period by Renard et al,16 suggesting that existing polymer catheters have a tendency to fail upon insertion.”
  • Other limitations include the use of trained nurses to manage insertions, relatively short duration of infusions, and limited ambulatory activities, which might not reflect the true prevalence of pressure-related or leakage events.

    “Other limitations, including the use of trained nurses to manage insertions rather than the subject, relatively short duration of infusions, and limited ambulatory activities by subjects, might not reflect the true prevalence of pressure-related or leakage events and unexplained hyperglycemia as reported by others9,16 but are inherent to the nature of the investigations performed.”

Cited by

Sorted by citations

Authors
Renard, E., Guerci, B., Leguerrier, A.-M., & Boizel, R.
Affiliations
  • Montpellier University Hospital
  • Centre Hospitalier Régional et Universitaire de Nancy (FR)
  • Centre Hospitalier Universitaire de Rennes (FR)
  • Roche (France) (FR)
Venue
Diabetes Technology & Therapeutics
Published
2010-10
Volume
12
Issue
10
Pages
769-773
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2044197170
Cited by
42
References
0
Citations by year
2024: 2 · 2023: 2 · 2022: 2 · 2021: 1 · 2020: 3 · 2019: 2 · 2018: 1 · 2016: 6 · 2015: 6 · 2014: 7 · 2013: 4 · 2012: 5
FWCI
2.41
Type
journal article
Language
en
Open access
closed
Locations
  • Diabetes Technology & Therapeutics (publishedVersion)
  • PubMed (publishedVersion)
Funders
Roche Diabetes Care
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
  • Health Sciences › Health Professions › Emergency Medical Services › Central Venous Catheters and Hemodialysis
Keywords
insulin pump therapy, infusion catheter, catheter-related complications, catheter replacement, type 1 diabetes
MeSH terms
Adult, Aged, Blood Glucose, Catheterization, Catheters, Indwelling, Diabetes Mellitus, Humans, Hyperglycemia, Insulin, Insulin Infusion Systems, Male, Middle Aged, Incidence, Cross-Over Studies, Diabetes Complications, Infusions, Subcutaneous, Catheter-Related Infections

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review