A New Index to Optimally Design and Compare Continuous Glucose Monitoring Glucose Prediction Algorithms
The DOI matches its Crossref record.
Abstract
BACKGROUND: Continuous glucose monitoring (CGM) data can be exploited to prevent hypo-/hyperglycemic events in real time by forecasting future glucose levels. In the last few years, several glucose prediction algorithms have been proposed, but how to compare them (e.g., methods based on polynomial rather than autoregressive time-series models) and even how to determine the optimal parameter set for a given method (e.g., prediction horizon and forgetting) are open problems. METHODS: A new index, J, is proposed to optimally design a prediction algorithm by taking into account two key components: the regularity of the predicted profile and the time gained thanks to prediction. Effectiveness of J is compared with previously proposed criteria such as the root mean square error (RMSE) and continuous glucose-error grid analysis (CG-EGA) on 20 Menarini (Florence, Italy) Glucoday® CGM data sets. RESULTS: For a given prediction algorithm, the new index J is able to suggest a more consistent and better parameter set (e.g., prediction horizon and forgetting factor of choice) than RMSE and CG-EGA. In addition, the minimization of J can reliably be used as a selection criterion in comparing different prediction methods. CONCLUSIONS: The new index can be used to compare different prediction strategies and to optimally design their parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Continuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes
Rodbard, D. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0035 · Cited by 458
A review of personalized blood glucose prediction strategies for T1DM patients
Oviedo, S., Vehí, J., Calm, R., & Armengol, J. (2017) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2833 · Cited by 279
“This metric was defined in terms of the ratio of regularity of the predicted glucose profile and the temporal gain.(47) Finally, energy of the second order difference (ESOD) denotes the normalized sum of the squared second‐order differences of predicted time series.”
BackgroundXie, J., & Wang, Q. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2975959 · Cited by 158
“…[8], and a normalized energy of the second-order difference ( ESOD n ) in glucose prediction, which characterizes the relative spurious oscillations in blood glucose prediction over the the actual time series, and has been used to reflect the risk of false alerts on hypo/hyper glycemia events [16].”
BackgroundMethodInfluentialZecchin, C., Facchinetti, A., Sparacino, G., & Cobelli, C. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816654161 · Cited by 64
Self-citation
Metadata
- Authors
- Facchinetti, A., Sparacino, G., Trifoglio, E., & Cobelli, C.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2011-02
- Volume
- 13
- Issue
- 2
- Pages
- 111-119
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2022832715
- Cited by
- 41
- References
- 0
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A New Index to Optimally Design and Compare Continuous Glucose Monitoring Glucose Prediction Algorithms. https://app.cochat.ai/papers/10.1089/dia.2010.0151
- The paper
- Facchinetti, A., Sparacino, G., Trifoglio, E., & Cobelli, C. (2011). A New Index to Optimally Design and Compare Continuous Glucose Monitoring Glucose Prediction Algorithms. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2010.0151
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.