How much is short-term glucose prediction in type 1 diabetes improved by adding insulin delivery and meal content information to CGM data? A Proof-of-Concept Study
Open accessAbstract
BACKGROUND: In type 1 diabetes (T1D) management, short-term glucose prediction can allow to anticipate therapeutic decisions when hypo/hyperglycemia is imminent. Literature prediction methods mainly use past continuous glucose monitoring (CGM) readings. Sophisticated algorithms can use information on insulin delivered and meal carbohydrate (CHO) content. The quantification of how much insulin and CHO information improves glucose prediction is missing in the literature and is investigated, in an open-loop setting, in this proof-of-concept study. METHODS: We adopted a versatile literature prediction methodology able to utilize a variety of inputs. We compared predictors that use (1) CGM; (2) CGM and insulin; (3) CGM and CHO; and (4) CGM, insulin, and CHO. Data of 15 T1D subjects in open-loop setup were used. Prediction was evaluated via absolute error and temporal gain focusing on meal/night periods. The relative importance of each individual input of the predictor was evaluated with a sensitivity analysis. RESULTS: For a prediction horizon (PH) ≥ 30 minutes, insulin and CHO information improves prediction accuracy of 10% and double the temporal gain during the 2 hours following the meal. During the night the 4 methods did not give statistically different results. When PH ≥ 45 minutes, the influence of CHO information on prediction is 5-fold that of insulin. CONCLUSIONS: In an open-loop setting, with PH ≥ 30 minutes, information on CHO and insulin improves short-term glucose prediction in the 2-hour time window following a meal, but not during the night. CHO information improves prediction significantly more than insulin.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Algorithms that use CGM data plus external inputs, such as ingested carbohydrates, injected insulin and physical activity, have been shown to enhance prediction performance compared to predictions using only CGM data.
“While, others use CGM data plus external inputs, such as the amount of ingested carbohydrates, injected insulin and physical activity [52]. These have been shown to enhance the performance of predictions when compared to predictions using only CGM data [53].”
From Advanced Diabetes Management Using Artificial Intelligence and Continuous Glucose Monitoring Sensors (2020) · cites this paper as [53]
Cites
Meal Simulation Model of the Glucose-Insulin System
Dalla Man, C., Rizza, R. A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893506 · Cited by 955 · see citing works
Self-citationSparacino, G., Zanderigo, F., Corazza, S., Maran, A., Facchinetti, A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889774 · Cited by 339 · see citing works
Self-citationA System Model of Oral Glucose Absorption: Validation on Gold Standard Data
Man, C. D., Camilleri, M., & Cobelli, C. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883792 · Cited by 313 · see citing works
Self-citationArtificial Neural Network Algorithm for Online Glucose Prediction from Continuous Glucose Monitoring
Pérez-Gandía, C., Facchinetti, A., Sparacino, G., Cobelli, C., Aguilera, E. J. G., Rigla, M., de Leiva, A., & Hernando, M. E. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0076 · Cited by 307 · see citing works
Self-citationSymmetrization of the Blood Glucose Measurement Scale and Its Applications
Kovatchev, B. P., Cox, D. J., Gonder-Frederick, L. A., & Clarke, W. L. (1997) · Diabetes Care · doi:10.2337/diacare.20.11.1655 · Cited by 258 · see citing works
GIM, Simulation Software of Meal Glucose–Insulin Model
Dalla Man, C., Raimondo, D. M., Rizza, R. A., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100303 · Cited by 253 · see citing works
Self-citationGeorga, E. I., Protopappas, V. C., Ardigò, D., Marina, M., Zavaroni, I., Polyzos, D., & Fotiadis, D. I. (2012) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/titb.2012.2219876 · Cited by 216 · see citing works
Dalla Man, C., Caumo, A., Basu, R., Rizza, R., Toffolo, G., & Cobelli, C. (2004) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00319.2003 · Cited by 198 · see citing works
Self-citationNeural Network-Based Real-Time Prediction of Glucose in Patients with Insulin-Dependent Diabetes
Pappada, S. M., Cameron, B. D., Rosman, P. M., Bourey, R. E., Papadimos, T. J., Olorunto, W. A., & Borst, M. J. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0104 · Cited by 182 · see citing works
Zecchin, C., Facchinetti, A., Sparacino, G., Nicolao, G. D., & Cobelli, C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2188893 · Cited by 181 · see citing works
Self-citationPrevention of Nocturnal Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension
Buckingham, B., Chase, H. P., Dassau, E., Cobry, E., Clinton, P., Gage, V., Caswell, K., Wilkinson, J., Cameron, F., Lee, H., et al. (2010) · Diabetes Care · doi:10.2337/dc09-2303 · Cited by 169 · see citing works
Estimation of Future Glucose Concentrations with Subject-Specific Recursive Linear Models
Eren-Oruklu, M., Çınar, A., Quinn, L. T., & SMITH, D. P. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0065 · Cited by 149 · see citing works
Real-Time Hypoglycemia Prediction Suite Using Continuous Glucose Monitoring
Dassau, E., Cameron, F., Lee, H., Bequette, B. W., Zisser, H., Jovanovič, L., Chase, H. P., Wilson, D. M., Buckingham, B. A., & Doyle, F. J. (2010) · Diabetes Care · doi:10.2337/dc09-1487 · Cited by 143 · see citing works
Predicting Subcutaneous Glucose Concentration in Humans: Data-Driven Glucose Modeling
Gani, A., Gribok, A. V., Rajaraman, S., Ward, W. K., & Jaques Reifman, A. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005937 · Cited by 129 · see citing works
Predictive Monitoring for Improved Management of Glucose Levels
Jaques Reifman, A., Rajaraman, S., Gribok, A. V., & Ward, W. K. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100405 · Cited by 123 · see citing works
Universal Glucose Models for Predicting Subcutaneous Glucose Concentration in Humans
Gani, A., Gribok, A. V., Lu, Y., Ward, W. K., Vigersky, R. A., & Jaques Reifman, A. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2034141 · Cited by 123 · see citing works
Zecchin, C., Facchinetti, A., Sparacino, G., & Cobelli, C. (2013) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2013.09.016 · Cited by 105 · see citing works
Self-citationHypoglycemia Early Alarm Systems Based on Multivariable Models
Turksoy, K., Bayrak, E. S., Quinn, L. T., Littlejohn, E., Rollins, D. K., & Çınar, A. (2013) · Industrial & Engineering Chemistry Research · doi:10.1021/ie3034015 · Cited by 104 · see citing works
Two-way interaction of input variables in the sensitivity analysis of neural network models
Gevrey, M., Dimopoulos, I. F., & Lek, S. (2006) · Ecological Modelling · doi:10.1016/j.ecolmodel.2005.11.008 · Cited by 103 · see citing works
Georga, E. I., Protopappas, V. C., Polyzos, D. K., & Fotiadis, D. I. (2015) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1263-1 · Cited by 98 · see citing works
Hughes, C. S., Patek, S. D., Breton, M. D., & Kovatchev, B. P. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400513 · Cited by 89 · see citing works
Shojaeefard, . H., Akbari, M., Tahani, M., & Farhani, F. (2013) · Advances in Materials Science and Engineering · doi:10.1155/2013/574914 · Cited by 85 · see citing works
Adaptive system identification for estimating future glucose concentrations and hypoglycemia alarms
Eren-Oruklu, M., Çınar, A., Rollins, D. K., & Quinn, L. T. (2012) · Automatica · doi:10.1016/j.automatica.2012.05.076 · Cited by 85 · see citing works
Daskalaki, E., Prountzou, A., Diem, P., & Mougiakakou, S. G. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0093 · Cited by 71 · see citing works
Experimental Evaluation of a Recursive Model Identification Technique for Type 1 Diabetes
Finan, D. A., Doyle, F. J., Palerm, C. C., Bevier, W. C., Zisser, H., Jovanovic, L. G., & Seborg, D. E. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300526 · Cited by 64 · see citing works
A meta-learning approach to the regularized learning—Case study: Blood glucose prediction
Naumova, V., Pereverzev, S. V., & Sivananthan, S. (2012) · Neural Networks · doi:10.1016/j.neunet.2012.05.004 · Cited by 60 · see citing works
Zhao, C., Dassau, E., Jovanovič, L., Zisser, H., Doyle, F. J., & Seborg, D. E. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600317 · Cited by 60 · see citing works
A predictive model of subcutaneous glucose concentration in type 1 diabetes based on Random Forests
Georga, E. I., Protopappas, V. C., Polyzos, D., & Fotiadis, D. I. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346567 · Cited by 49 · see citing works
Zecchin, C., Facchinetti, A., Sparacino, G., & Cobelli, C. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0208 · Cited by 47 · see citing works
Self-citationLimitations to subcutaneous insulin administration in type 1 diabetes
Chen, J., Christiansen, J. S., & Lauritzen, T. (2003) · Diabetes Obesity and Metabolism · doi:10.1046/j.1463-1326.2003.00266.x · Cited by 42 · see citing works
Facchinetti, A., Sparacino, G., Trifoglio, E., & Cobelli, C. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0151 · Cited by 41 · see citing works
Self-citationZecchin, C., Facchinetti, A., Sparacino, G., Man, C. D., Manohar, C. U., Levine, J. A., Basu, A., Kudva, Y. C., & Cobelli, C. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0105 · Cited by 28 · see citing works
Self-citationNonlinear gain in online prediction of blood glucose profile in type 1 diabetic patients
Estrada, G. C., del Re, L., & Renard, É. (2010) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2010.5717390 · Cited by 18 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Continuous glucose monitoring sensors: past, present and future algorithmic challenges
Facchinetti, A. (2016) · Sensors · doi:10.3390/s16122093 · Cited by 176 · see citing works
Self-citationAdvanced Diabetes Management Using Artificial Intelligence and Continuous Glucose Monitoring Sensors
Vettoretti, M., Cappon, G., Facchinetti, A., & Sparacino, G. (2020) · Sensors · doi:10.3390/s20143870 · Cited by 176 · see citing works
Self-citationXie, J., & Wang, Q. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2975959 · Cited by 158 · see citing works
- Authors
- Zecchin, C., Facchinetti, A., Sparacino, G., & Cobelli, C.
- Affiliations
- University of Padua (IT)
- Corresponding author
- Cobelli, Claudio
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2016-07-10
- Volume
- 10
- Issue
- 5
- Pages
- 1149-1160
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC5032963
- OpenAlex
- W2474805097
- Cited by
- 64
- References
- 33
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 7 · 2023: 7 · 2022: 7 · 2021: 12 · 2020: 9 · 2019: 6 · 2018: 7 · 2017: 4 · 2016: 1
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
- Keywords
- type 1 diabetes, continuous glucose monitoring, insulin delivery, prediction horizon, sensitivity analysis
- MeSH terms
- Algorithms, Blood Glucose, Diabetes Mellitus, Type 1, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Blood Glucose Self-Monitoring, Meals
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review