Automated Overnight Closed-Loop Glucose Control in Young Children with Type 1 Diabetes

Elleri, Daniela, Allen, Janet M., Nodale, Marianna, Wilinska, Malgorzata E., Mangat, Jasdip S., Larsen, Anne Mette F., Acerini, Carlo L., Dunger, David B., Hovorka, Roman · 2011 · Diabetes Technology & Therapeutics
Cited by 57

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

BACKGROUND: We evaluated the effectiveness of automated overnight closed-loop (AOCL) insulin delivery and the influence of timing of initiation on glucose control overnight in young children with type 1 diabetes (T1D). METHODS: Eight children with T1D (four boys, four girls) (mean ± SD: 9.4 ± 2.7 years old; body mass index, 18.3 ± 2.3 kg/m(2); duration of diabetes, 3.9 ± 2.5 years; total daily insulin dose, 0.7 ± 0.1 U/kg/day; glycosylated hemoglobin, 7.9 ± 0.9%) were studied in a clinical research facility on two separate occasions. Subjects had a meal at 18:00 (77 ± 8 g of carbohydrate [CHO]) and snack at 21:00 (21 ± 6 g of CHO), both accompanied by a prandial insulin bolus. In random order, AOCL was started at 18:00 or 21:00 h and ran until 08:00 h the next day. Subcutaneous continuous glucose monitoring data were fed automatically into the model predictive control algorithm. Calculated subcutaneous insulin infusion rates were sent wirelessly to an insulin pump. Plasma glucose was measured to assess closed-loop performance. RESULTS: No rescue CHOs were administered. Time spent with plasma glucose in the target range from 3.9 to 8.0 mmol/L was 50.7% (29.0%, 72.2%), and it did not differ on the two occasions: median (interquartile range), 42% (18%, 64%) versus 58% (32%, 79%) (P = 0.161). Time when plasma glucose was above 8.0 mmol/L (42% [25%, 82%] vs. 29% [14%, 64%], P = 0.093), time below 3.9 mmol/L (0% [0%, 11%] vs. 8% [0%, 17%], P = 0.500), low blood glucose index (0.1 [0.0, 2.5] vs. 1.7 [0.4, 3.3], P = 0.380), plasma glucose at the start of AOCL (12.5 ± 2.7 vs. 11.6 ± 4.2 mmol/L, P = 0.562), and mean overnight plasma glucose (8.3 ± 2.1 vs. 7.5 ± 2.2 mmol/L, P = 0.246) were also similar. CONCLUSIONS: AOCL is feasible in young children with T1D. Comparable results were obtained when closed-loop was initiated at 18:00 or 21:00 h.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2010.0176

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 57

Metadata

Authors
Elleri, D., Allen, J. M., Nodale, M., Wilinska, M. E., Mangat, J. S., Larsen, A. M. F., Acerini, C. L., Dunger, D. B., & Hovorka, R.
Venue
Diabetes Technology & Therapeutics
Published
2011-04
Volume
13
Issue
4
Pages
419-424
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W1987013810
Cited by
57
References
7
FWCI
8.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated Overnight Closed-Loop Glucose Control in Young Children with Type 1 Diabetes. https://app.cochat.ai/papers/10.1089/dia.2010.0176
The paper
Elleri, D., Allen, J. M., Nodale, M., Wilinska, M. E., Mangat, J. S., Larsen, A. M. F., Acerini, C. L., Dunger, D. B., & Hovorka, R. (2011). Automated Overnight Closed-Loop Glucose Control in Young Children with Type 1 Diabetes. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2010.0176

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.