Automated Overnight Closed-Loop Glucose Control in Young Children with Type 1 Diabetes
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND: We evaluated the effectiveness of automated overnight closed-loop (AOCL) insulin delivery and the influence of timing of initiation on glucose control overnight in young children with type 1 diabetes (T1D). METHODS: Eight children with T1D (four boys, four girls) (mean ± SD: 9.4 ± 2.7 years old; body mass index, 18.3 ± 2.3 kg/m(2); duration of diabetes, 3.9 ± 2.5 years; total daily insulin dose, 0.7 ± 0.1 U/kg/day; glycosylated hemoglobin, 7.9 ± 0.9%) were studied in a clinical research facility on two separate occasions. Subjects had a meal at 18:00 (77 ± 8 g of carbohydrate [CHO]) and snack at 21:00 (21 ± 6 g of CHO), both accompanied by a prandial insulin bolus. In random order, AOCL was started at 18:00 or 21:00 h and ran until 08:00 h the next day. Subcutaneous continuous glucose monitoring data were fed automatically into the model predictive control algorithm. Calculated subcutaneous insulin infusion rates were sent wirelessly to an insulin pump. Plasma glucose was measured to assess closed-loop performance. RESULTS: No rescue CHOs were administered. Time spent with plasma glucose in the target range from 3.9 to 8.0 mmol/L was 50.7% (29.0%, 72.2%), and it did not differ on the two occasions: median (interquartile range), 42% (18%, 64%) versus 58% (32%, 79%) (P = 0.161). Time when plasma glucose was above 8.0 mmol/L (42% [25%, 82%] vs. 29% [14%, 64%], P = 0.093), time below 3.9 mmol/L (0% [0%, 11%] vs. 8% [0%, 17%], P = 0.500), low blood glucose index (0.1 [0.0, 2.5] vs. 1.7 [0.4, 3.3], P = 0.380), plasma glucose at the start of AOCL (12.5 ± 2.7 vs. 11.6 ± 4.2 mmol/L, P = 0.562), and mean overnight plasma glucose (8.3 ± 2.1 vs. 7.5 ± 2.2 mmol/L, P = 0.246) were also similar. CONCLUSIONS: AOCL is feasible in young children with T1D. Comparable results were obtained when closed-loop was initiated at 18:00 or 21:00 h.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
El-Khatib, F. H., Russell, S. J., Nathan, D. M., Sutherlin, R. G., & Damiano, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000619 · Cited by 403
Davis, E. A., Keating, B., Byrne, G. C., Russell, M., & Jones, T. W. (1997) · Diabetes Care · doi:10.2337/diacare.20.1.22 · Cited by 273 · cited 2×
“15 Nocturnal hypoglycemia has been shown to be frequent and prolonged in young patients wearing glucose sensors.”
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-2081 · Cited by 180
Haugstvedt, A., Wentzel‐Larsen, T., Graue, M., Søvik, O., & Rokne, B. (2010) · Diabetic Medicine · doi:10.1111/j.1464-5491.2009.02867.x · Cited by 172
Assessment and management of hypoglycemia in children and adolescents with diabetes
Clarke, W., Jones, T., Rewers, A., Dunger, D., & Klingensmith, G. J. (2009) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2009.00583.x · Cited by 135
Self-citationBeregszàszi, M., Tubiana-Rufi, N., Benali, K., Noël, M., Bloch, J., & Czernichow, P. (1997) · The Journal of Pediatrics · doi:10.1016/s0022-3476(97)70121-5 · Cited by 122
Cited by
Nocturnal Glucose Control with an Artificial Pancreas at a Diabetes Camp
Phillip, M., Battelino, T., Atlas, E., Kordonouri, O., Bratina, N., Miller, S., Biester, T., Avbelj Stefanija, M., Muller, I., Nimri, R., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1206881 · Cited by 435
Closed-Loop Artificial Pancreas Systems: Engineering the Algorithms
Doyle, F. J., Huyett, L. M., Lee, J. B., Zisser, H. C., & Dassau, E. (2014) · Diabetes Care · doi:10.2337/dc13-2108 · Cited by 394
Closed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Self-citationBreton, M. D., Cherñavvsky, D. R., Forlenza, G. P., DeBoer, M. D., Robic, J., Wadwa, R. P., Messer, L. H., Kovatchev, B. P., & Maahs, D. M. (2017) · Diabetes Care · doi:10.2337/dc17-0883 · Cited by 179
“control while decreasing the rates of hyperglycemia and hypoglycemia in inpatient trials (5,10,11), at diabetes camps”
BackgroundChallenges and recent progress in the development of a closed-loop artificial pancreas
Bequette, B. W. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.007 · Cited by 183
Metadata
- Authors
- Elleri, D., Allen, J. M., Nodale, M., Wilinska, M. E., Mangat, J. S., Larsen, A. M. F., Acerini, C. L., Dunger, D. B., & Hovorka, R.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2011-04
- Volume
- 13
- Issue
- 4
- Pages
- 419-424
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1987013810
- Cited by
- 57
- References
- 7
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated Overnight Closed-Loop Glucose Control in Young Children with Type 1 Diabetes. https://app.cochat.ai/papers/10.1089/dia.2010.0176
- The paper
- Elleri, D., Allen, J. M., Nodale, M., Wilinska, M. E., Mangat, J. S., Larsen, A. M. F., Acerini, C. L., Dunger, D. B., & Hovorka, R. (2011). Automated Overnight Closed-Loop Glucose Control in Young Children with Type 1 Diabetes. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2010.0176
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.