Multivariable Adaptive Closed-Loop Control of an Artificial Pancreas Without Meal and Activity Announcement
Open accessAbstract
BACKGROUND: Accurate closed-loop control is essential for developing artificial pancreas (AP) systems that adjust insulin infusion rates from insulin pumps. Glucose concentration information from continuous glucose monitoring (CGM) systems is the most important information for the control system. Additional physiological measurements can provide valuable information that can enhance the accuracy of the control system. Proportional-integral-derivative control and model predictive control have been popular in AP development. Their implementations to date rely on meal announcements (e.g., bolus insulin dose based on insulin:carbohydrate ratios) by the user. Adaptive control techniques provide a powerful alternative that do not necessitate any meal or activity announcements. MATERIALS AND METHODS: Adaptive control systems based on the generalized predictive control framework are developed by extending the recursive modeling techniques. Physiological signals such as energy expenditure and galvanic skin response are used along with glucose measurements to generate a multiple-input-single-output model for predicting future glucose concentrations used by the controller. Insulin-on-board (IOB) is also estimated and used in control decisions. The controllers were tested with clinical studies that include seven cases with three different patients with type 1 diabetes for 32 or 60 h without any meal or activity announcements. RESULTS: The adaptive control system kept glucose concentration in the normal preprandial and postprandial range (70-180 mg/dL) without any meal or activity announcements during the test period. After IOB estimation was added to the control system, mild hypoglycemic episodes were observed only in one of the four experiments. This was reflected in a plasma glucose value of 56 mg/dL (YSI 2300 STAT; Yellow Springs Instrument, Yellow Springs, OH) and a CGM value of 63 mg/dL). CONCLUSIONS: Regulation of blood glucose concentration with an AP using adaptive control techniques was successful in clinical studies, even without any meal and physical activity announcement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Kovatchev, B., Cobelli, C., Renard, E., Anderson, S., Breton, M., Patek, S., Clarke, W., Bruttomesso, D., Maran, A., Costa, S., et al. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400611 · Cited by 200
Clarke, W. L., Anderson, S., Breton, M., Patek, S., Kashmer, L., & Kovatchev, B. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300506 · Cited by 185
Ward, W. K., Castle, J. R., & Youssef, J. E. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500608 · Cited by 36
Cited by
Closed-Loop Artificial Pancreas Systems: Engineering the Algorithms
Doyle, F. J., Huyett, L. M., Lee, J. B., Zisser, H. C., & Dassau, E. (2014) · Diabetes Care · doi:10.2337/dc13-2108 · Cited by 394
Breton, M. D., Brown, S. A., Karvetski, C. H., Kollar, L., Topchyan, K. A., Anderson, S. M., & Kovatchev, B. P. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0333 · Cited by 128
Jacobs, P. G., El Youssef, J., Reddy, R., Resalat, N., Branigan, D., Condon, J., Preiser, N., Ramsey, K., Jones, M., Edwards, C., et al. (2016) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.12707 · Cited by 116
Gingras, V., Taleb, N., Roy‐Fleming, A., Legault, L., & Rabasa‐Lhoret, R. (2018) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13052 · Cited by 113
Jacobs, P. G., Herrero, P., Facchinetti, A., Vehi, J., Kovatchev, B., Breton, M. D., Cinar, A., Nikita, K. S., Doyle, F. J., Bondia, J., et al. (2024) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2023.3331297 · Cited by 113
Self-citationJacobs, P. G., Resalat, N., El Youssef, J., Reddy, R., Branigan, D., Preiser, N., Condon, J., & Castle, J. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815609371 · Cited by 105
An Integrated Multivariable Artificial Pancreas Control System
Turksoy, K., Quinn, L. T., Littlejohn, E., & Cinar, A. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814524862 · Cited by 77
Self-citationEarly detection of physical activity for people with type 1 diabetes mellitus
Dasanayake, I. S., Bevier, W. C., Castorino, K., Pinsker, J. E., Seborg, D. E., Doyle, F. J., & Dassau, E. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815592409 · Cited by 40
(2016) · ArODES (HES-SO (https://www.hes-so.ch/)) · Cited by 7
Metadata
- Authors
- Turksoy, K., Bayrak, E. S., Quinn, L., Littlejohn, E., & Cinar, A.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2013-05
- Volume
- 15
- Issue
- 5
- Pages
- 386-400
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2092559456
- Cited by
- 161
- References
- 4
- FWCI
- 11.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.