Accuracy and Robustness of Dynamical Tracking of Average Glycemia (A1c) to Provide Real-Time Estimation of Hemoglobin A1c Using Routine Self-Monitored Blood Glucose Data
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Laboratory hemoglobin A1c (HbA1c) assays are typically done only every few months. However, self-monitored blood glucose (SMBG) readings offer the possibility for real-time estimation of HbA1c. We present a new dynamical method tracking changes in average glycemia to provide real-time estimation of A1c (eA1c). MATERIALS AND METHODS: A new two-step algorithm was constructed that includes: (1) tracking fasting glycemia to compute base eA1c updated with every fasting SMBG data point and (2) calibration of the base eA1c trace with monthly seven-point SMBG profiles to capture the principal components of blood glucose variability and produce eA1c. A training data set (n=379 subjects) was used to estimate model parameters. The model was then fixed and applied to an independent test data set (n=375 subjects). Accuracy was evaluated in the test data set by computing mean absolute deviation (MAD) and mean absolute relative deviation (MARD) of eA1c from reference HbA1c, as well as eA1c-HbA1c correlation. RESULTS: MAD was 0.50, MARD was 6.7%, and correlation between eA1c and reference HbA1c was r=0.76. Using an HbA1c error grid plot, 77.5% of all eA1c fell within 10% from reference HbA1c, and 97.9% fell within 20% from reference. CONCLUSIONS: A dynamical estimation model was developed that achieved accurate tracking of average glycemia over time. The model is capable of working with infrequent SMBG data typical for type 2 diabetes, thereby providing a new tool for HbA1c estimation at the patient level. The computational demands of the procedure are low; thus it is readily implementable into home SMBG meters. Real-time HbA1c estimation could increase patients' motivation to improve diabetes control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Translating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
Goldstein, D. E., Little, R. R., Lorenz, R. A., Malone, J. I., Nathan, D., Peterson, C. M., & Sacks, D. B. (2004) · Diabetes Care · doi:10.2337/diacare.27.7.1761 · Cited by 625
Parkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620
Heisler, M., Piette, J. D., Spencer, M., Kieffer, E., & Vijan, S. (2005) · Diabetes Care · doi:10.2337/diacare.28.4.816 · Cited by 326
Evaluating the Accuracy of Continuous Glucose-Monitoring Sensors
Kovatchev, B. P., Gonder-Frederick, L. A., Cox, D. J., & Clarke, W. L. (2004) · Diabetes Care · doi:10.2337/diacare.27.8.1922 · Cited by 312
Self-citation
Cited by
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationMetrics for glycaemic control - from HbA1c to continuous glucose monitoring
Kovatchev, B. P. (2017) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2017.3 · Cited by 272
Self-citationMalka, R., Nathan, D. M., & Higgins, J. M. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf9304 · Cited by 134
“Previous studies have developed sophisticated methods to estimate HbA1c by combining prior HbA1c levels with multipoint profiles of self-monitored glucose (26).”
MethodFabris, C., Heinemann, L., Beck, R., Cobelli, C., & Kovatchev, B. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0236 · Cited by 58
Self-citation
Metadata
- Authors
- Kovatchev, B. P., Flacke, F., Sieber, J., & Breton, M. D.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2014-05
- Volume
- 16
- Issue
- 5
- Pages
- 303-309
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2170243859
- Cited by
- 34
- References
- 5
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy and Robustness of Dynamical Tracking of Average Glycemia (A1c) to Provide Real-Time Estimation of Hemoglobin A1c Using Routine Self-Monitored Blood Glucose Data. https://app.cochat.ai/papers/10.1089/dia.2013.0224
- The paper
- Kovatchev, B. P., Flacke, F., Sieber, J., & Breton, M. D. (2014). Accuracy and Robustness of Dynamical Tracking of Average Glycemia (A1c) to Provide Real-Time Estimation of Hemoglobin A1c Using Routine Self-Monitored Blood Glucose Data. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2013.0224
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.