Brown, Sue A., Kovatchev, Boris P., Breton, Marc D., Anderson, Stacey M., Keith-Hynes, Patrick, Patek, Stephen D., Jiang, Boyi, Ben Brahim, Najib, Vereshchetin, Paul, Bruttomesso, Daniela, Avogaro, Angelo, Del Favero, Simone, Boscari, Federico, Galasso, Silvia, Visentin, Roberto, Monaro, Marco, Cobelli, Claudio · 2015 · Diabetes Technology & Therapeutics
Cited by 64

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Studies of closed-loop control (CLC) systems have improved glucose levels in patients with type 1 diabetes. In this study we test a new CLC concept aiming to "reset" the patient overnight to near-normoglycemia each morning, for several consecutive nights. SUBJECTS AND METHODS: Ten insulin pump users with type 1 diabetes (mean age, 46.4±8.5 years) were enrolled in a two-center (in the United States and Italy) randomized crossover trial comparing 5 consecutive nights of CLC (23:00-07:00 h) in an outpatient setting versus sensor-augmented insulin pump therapy of the same duration at home. Primary end points included time spent in 80-140 mg/dL as measured by continuous glucose monitoring overnight and fasting blood glucose distribution at 7:00 h. RESULTS: Compared with sensor-augmented pump therapy, CLC improved significantly time spent between 80 and 140 mg/dL (54.5% vs. 32.2%; P<0.001) and between 70 and 180 mg/dL (85.4% vs. 59.1%; P<0.001); CLC reduced the mean glucose level at 07:00 h (119.3 vs. 152.9 mg/dL; P<0.001) and overnight mean glucose level (139.0 vs. 170.3 mg/dL; P<0.001) using a marginally lower amount of insulin (6.1 vs. 6.8 units; P=0.1). Tighter overnight control led to improved daytime control on the next day: the overnight/next-day control correlation was r=0.52, P<0.01. CONCLUSIONS: Multinight CLC of insulin delivery (artificial pancreas) results in significant improvement in morning and overnight glucose levels and time in target range, with the potential to improve daytime control when glucose levels were "reset" to near-normoglycemia each morning.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2014.0259

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 64

Metadata

Authors
Brown, S. A., Kovatchev, B. P., Breton, M. D., Anderson, S. M., Keith-Hynes, P., Patek, S. D., Jiang, B., Ben Brahim, N., Vereshchetin, P., Bruttomesso, D., Avogaro, A., Del Favero, S., Boscari, F., Galasso, S., Visentin, R., Monaro, M., & Cobelli, C.
Venue
Diabetes Technology & Therapeutics
Published
2015-03
Volume
17
Issue
3
Pages
203-209
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W115895616
Cited by
64
References
4
FWCI
8.61
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multinight “Bedside” Closed-Loop Control for Patients with Type 1 Diabetes. https://app.cochat.ai/papers/10.1089/dia.2014.0259
The paper
Brown, S. A., Kovatchev, B. P., Breton, M. D., Anderson, S. M., Keith-Hynes, P., Patek, S. D., Jiang, B., Ben Brahim, N., Vereshchetin, P., Bruttomesso, D., Avogaro, A., Del Favero, S., Boscari, F., Galasso, S., Visentin, R., Monaro, M., & Cobelli, C. (2015). Multinight “Bedside” Closed-Loop Control for Patients with Type 1 Diabetes. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2014.0259

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.