Taking a Closer Look—Continuous Glucose Monitoring in Non-Critically Ill Hospitalized Patients with Type 2 Diabetes Mellitus Under Basal-Bolus Insulin Therapy
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Inpatient glucose management is based on four daily capillary blood glucose (BG) measurements. The aim was to test the capability of continuous glucose monitoring (CGM) for assessing the clinical impact and safety of basal-bolus insulin therapy in non-critically ill hospitalized patients with type 2 diabetes mellitus (T2DM). MATERIALS AND METHODS: Eighty-four patients with T2DM (age, 68±10 years; glycosylated hemoglobin, 72±28 mmol/mol; body mass index, 31±7 kg/m(2)) were treated with basal-bolus insulin. CGM was performed with the iPro(®)2 system (Medtronic MiniMed, Northridge, CA) and calibrated retrospectively. RESULTS: A remarkable consistency between CGM and BG measurements and therapy improvement was shown over the study period of 501 patient-days. The number of CGM and BG measurements (CGM/BG) in the range from 3.9-10 mmol/L increased from 67.7%/67.2% (on Day 1) to 77.5%/78.6% (on the last day) (P<0.04). The number of low glycemic episodes (3.3 to <3.9 mmol/L) during nighttime detected by CGM was 15-fold higher, and the number of episodes >13.9 mmol/L detected by CGM during night was 12.5-fold higher than the values from the BG measurements. Ninety-nine percent of data points were in the clinically accurate or acceptable Clarke Error Grid Zones A+B, and the relative numbers of correctly identified episodes of <3.9 and >13.9 mmol/L detected by CGM (sensitivity) were 47.3% and 81.5%, respectively. CONCLUSIONS: Our data exhibit a good agreement between overall CGM and BG measurements, but there were a high number of missed hypo- and hyperglycemic episodes with BG measurements, particularly during nighttime. Overall assessment of glycemic control using CGM is feasible, whereas the use of CGM for individualized therapy decisions needs further improvement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards of medical care in diabetes—2014
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s014 · Cited by 4,572
Moghissi, E. S., Korytkowski, M. T., DiNardo, M., Einhorn, D., Hellman, R., Hirsch, I. B., Inzucchi, S. E., Ismail-Beigi, F., Kirkman, M. S., & Umpierrez, G. E. (2009) · Diabetes Care · doi:10.2337/dc09-9029 · Cited by 1,444
Umpierrez, G. E., Smiley, D., Zisman, A., Prieto, L. M., Palacio, A., Ceron, M., Puig, A., & Mejia, R. (2007) · Diabetes Care · doi:10.2337/dc07-0295 · Cited by 671
Bergenstal, R. M., Ahmann, A. J., Bailey, T., Beck, R. W., Bissen, J., Buckingham, B., Deeb, L., Dolin, R. H., Garg, S. K., Goland, R., et al. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0051 · Cited by 307
Umpierrez, G. E., Smiley, D., Hermayer, K., Khan, A., Olson, D. E., Newton, C., Jacobs, S., Rizzo, M., Peng, L., Reyes, D., et al. (2013) · Diabetes Care · doi:10.2337/dc12-1988 · Cited by 222
Poolsup, N., Suksomboon, N., & Kyaw, A. M. (2013) · Diabetology & Metabolic Syndrome · doi:10.1186/1758-5996-5-39 · Cited by 179 · cited 1×
“These findings suggest that high numbers of possibly clinically relevant episodes are missed because of the low number of measurements during nighttime, which is in good agreement with previous studies.(14,24,28)”
Cited by
Korytkowski, M. T., Muniyappa, R., Antinori-Lent, K., Donihi, A. C., Drincic, A. T., Hirsch, I. B., Luger, A., McDonnell, M. E., Murad, M. H., Nielsen, C., et al. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac278 · Cited by 315
“12 mg/dL); moderate level of certainty] (12-14, 16-20).”
BackgroundMethodInfluentialGalindo, R. J., Migdal, A. L., Davis, G. M., Urrutia, M. A., Albury, B., Zambrano, C., Vellanki, P., Pasquel, F. J., Fayfman, M., Peng, L., et al. (2020) · Diabetes Care · doi:10.2337/dc19-2073 · Cited by 181
“9–99% (7,22) of values falling into zones A and B of the error grid analysis, respectively.”
BackgroundMethodContinuous glucose monitors and automated insulin dosing systems in the hospital consensus guideline
Galindo, R. J., Umpierrez, G. E., Rushakoff, R. J., Basu, A., Lohnes, S., Nichols, J. H., Spanakis, E. K., Espinoza, J., Palermo, N. E., Awadjie, D. G., et al. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820954163 · Cited by 170
Singh, L. G., Satyarengga, M., Marcano, I., Scott, W. H., Pinault, L. F., Feng, Z., Sorkin, J. D., Umpierrez, G. E., & Spanakis, E. K. (2020) · Diabetes Care · doi:10.2337/dc20-0840 · Cited by 154
Seisa, M. O., Saadi, S., Nayfeh, T., Muthusamy, K., Shah, S. H., Firwana, M., Hasan, B., Jawaid, T., Abd-Rabu, R., Korytkowski, M. T., et al. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac277 · Cited by 65
Metadata
- Authors
- Schaupp, L., Donsa, K., Neubauer, K. M., Mader, J. K., Aberer, F., Höll, B., Spat, S., Augustin, T., Beck, P., Pieber, T. R., & Plank, J.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2015-09
- Volume
- 17
- Issue
- 9
- Pages
- 611-618
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2145516778
- Cited by
- 47
- References
- 6
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Taking a Closer Look—Continuous Glucose Monitoring in Non-Critically Ill Hospitalized Patients with Type 2 Diabetes Mellitus Under Basal-Bolus Insulin Therapy. https://app.cochat.ai/papers/10.1089/dia.2014.0343
- The paper
- Schaupp, L., Donsa, K., Neubauer, K. M., Mader, J. K., Aberer, F., Höll, B., Spat, S., Augustin, T., Beck, P., Pieber, T. R., & Plank, J. (2015). Taking a Closer Look—Continuous Glucose Monitoring in Non-Critically Ill Hospitalized Patients with Type 2 Diabetes Mellitus Under Basal-Bolus Insulin Therapy. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2014.0343
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.