CoChat

Taking a Closer Look—Continuous Glucose Monitoring in Non-Critically Ill Hospitalized Patients with Type 2 Diabetes Mellitus Under Basal-Bolus Insulin Therapy

Schaupp, Lukas, Donsa, Klaus, Neubauer, Katharina M., Mader, Julia K., Aberer, Felix, Höll, Bernhard, Spat, Stephan, Augustin, Thomas, Beck, Peter, Pieber, Thomas R., Plank, Johannes · 2015 · Diabetes Technology & Therapeutics
Cited by 47

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Inpatient glucose management is based on four daily capillary blood glucose (BG) measurements. The aim was to test the capability of continuous glucose monitoring (CGM) for assessing the clinical impact and safety of basal-bolus insulin therapy in non-critically ill hospitalized patients with type 2 diabetes mellitus (T2DM). MATERIALS AND METHODS: Eighty-four patients with T2DM (age, 68±10 years; glycosylated hemoglobin, 72±28 mmol/mol; body mass index, 31±7 kg/m(2)) were treated with basal-bolus insulin. CGM was performed with the iPro(®)2 system (Medtronic MiniMed, Northridge, CA) and calibrated retrospectively. RESULTS: A remarkable consistency between CGM and BG measurements and therapy improvement was shown over the study period of 501 patient-days. The number of CGM and BG measurements (CGM/BG) in the range from 3.9-10 mmol/L increased from 67.7%/67.2% (on Day 1) to 77.5%/78.6% (on the last day) (P<0.04). The number of low glycemic episodes (3.3 to <3.9 mmol/L) during nighttime detected by CGM was 15-fold higher, and the number of episodes >13.9 mmol/L detected by CGM during night was 12.5-fold higher than the values from the BG measurements. Ninety-nine percent of data points were in the clinically accurate or acceptable Clarke Error Grid Zones A+B, and the relative numbers of correctly identified episodes of <3.9 and >13.9 mmol/L detected by CGM (sensitivity) were 47.3% and 81.5%, respectively. CONCLUSIONS: Our data exhibit a good agreement between overall CGM and BG measurements, but there were a high number of missed hypo- and hyperglycemic episodes with BG measurements, particularly during nighttime. Overall assessment of glycemic control using CGM is feasible, whereas the use of CGM for individualized therapy decisions needs further improvement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2014.0343

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Schaupp, L., Donsa, K., Neubauer, K. M., Mader, J. K., Aberer, F., Höll, B., Spat, S., Augustin, T., Beck, P., Pieber, T. R., & Plank, J.
Venue
Diabetes Technology & Therapeutics
Published
2015-09
Volume
17
Issue
9
Pages
611-618
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2145516778
Cited by
47
References
6
FWCI
2.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.