CoChat

Association Between Heart Rate Variability Measures and Blood Glucose Levels: Implications for Noninvasive Glucose Monitoring for Diabetes

Rothberg, Leon J., Lees, Ty, Clifton-Bligh, Roderick, Lal, Sara · 2016 · Diabetes Technology & Therapeutics
Cited by 57

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Diabetes mellitus (DM) is a global metabolic epidemic associated with numerous adverse complications. Invasive finger prick tests or invasive monitors are currently the most common means of monitoring and controlling blood glucose levels (BGLs). Heart rate variability (HRV) is a noninvasive measure of the autonomic nervous system, and its dynamic physiological nature may provide an alternative means of blood glucose monitoring. However, the relationship between BGL and HRV parameters remains relatively unknown. MATERIALS AND METHODS: Thirty-two participants with diabetes (39.97 ± 17.21 years of age) and 31 without diabetes (27.87 ± 10.55 years of age) participated in the current study. Fasting preceded a 10-min three-lead electrocardiogram (ECG), which was followed by a finger prick blood glucose assessment. Following this, a regular meal was consumed, and 30 min after ingestion, a second postprandial 10-min ECG was obtained, and blood glucose assessment was conducted. RESULTS: Low-frequency (LF) power, high-frequency (HF) power, and total power (TP) of HRV were negatively associated with BGL in participants with DM. Additionally, the ratio of LF to HF was positively correlated with BGL. Duration of DM was also associated with multiple HRV parameters, with negative associations to both LF and HF parameters as well as TP. CONCLUSIONS: This study demonstrates links between specific HRV variables and BGL. In the future the dynamic nature of HRV could provide a unique and real-time method for monitoring BGL, for continuous noninvasive prediction and/or management of DM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2016.0010

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 57

Metadata

Authors
Rothberg, L. J., Lees, T., Clifton-Bligh, R., & Lal, S.
Venue
Diabetes Technology & Therapeutics
Published
2016-06
Volume
18
Issue
6
Pages
366-376
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2409376265
Cited by
57
References
14
FWCI
4.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Association Between Heart Rate Variability Measures and Blood Glucose Levels: Implications for Noninvasive Glucose Monitoring for Diabetes. https://app.cochat.ai/papers/10.1089/dia.2016.0010
The paper
Rothberg, L. J., Lees, T., Clifton-Bligh, R., & Lal, S. (2016). Association Between Heart Rate Variability Measures and Blood Glucose Levels: Implications for Noninvasive Glucose Monitoring for Diabetes. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2016.0010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.