CoChat

Design and Clinical Evaluation of a Novel Low-Glucose Prediction Algorithm with Mini-Dose Stable Glucagon Delivery in Post-Bariatric Hypoglycemia

Open access
Laguna Sanz, Alejandro J., Mulla, Christopher M., Fowler, Kristen M., Cloutier, Emilie, Goldfine, Allison B., Newswanger, Brett, Cummins, Martin, Deshpande, Sunil, Prestrelski, Steven J., Strange, Poul, Zisser, Howard, Doyle, Francis J., Dassau, Eyal, Patti, Mary-Elizabeth · 2018 · Diabetes Technology & Therapeutics
Cited by 34

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Postbariatric hypoglycemia (PBH) is a complication of bariatric surgery with limited therapeutic options. We developed an event-based system to predict and detect hypoglycemia based on continuous glucose monitor (CGM) data and recommend delivery of minidose liquid glucagon. METHODS: We performed an iterative development clinical study employing a novel glucagon delivery system: a Dexcom CGM connected to a Windows tablet running a hypoglycemia prediction algorithm and an Omnipod pump filled with an investigational stable liquid glucagon formulation. Meal tolerance testing was performed in seven participants with PBH and history of neuroglycopenia. Glucagon was administered when hypoglycemia was predicted. Primary outcome measures included the safety and feasibility of this system to predict and prevent severe hypoglycemia. Secondary outcomes included hypoglycemia prediction by the prediction algorithm, minimization of time below hypoglycemia threshold using glucagon, and prevention of rebound hyperglycemia. RESULTS: The hypoglycemia prediction algorithm alerted for impending hypoglycemia in the postmeal state, prompting delivery of glucagon (150 μg). After observations of initial incomplete efficacy to prevent hypoglycemia in the first two participants, system modifications were implemented: addition of PBH-specific detection algorithm, increased glucagon dose (300 μg), and a second glucagon dose if needed. These modifications, together with rescue carbohydrates provided to some participants, contributed to progressive improvements in glucose time above the hypoglycemia threshold (75 mg/dL). CONCLUSIONS: Preliminary results indicate that our event-based automatic monitoring algorithm successfully predicted likely hypoglycemia. Minidose glucagon therapy was well tolerated, without prolonged or severe hypoglycemia, and without rebound hyperglycemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2017.0298

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 34

Metadata

Authors
Laguna Sanz, A. J., Mulla, C. M., Fowler, K. M., Cloutier, E., Goldfine, A. B., Newswanger, B., Cummins, M., Deshpande, S., Prestrelski, S. J., Strange, P., Zisser, H., Doyle, F. J., Dassau, E., & Patti, M.-E.
Venue
Diabetes Technology & Therapeutics
Published
2018-02
Volume
20
Issue
2
Pages
127-139
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2784732818
Cited by
34
References
13
FWCI
2.56
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.