CoChat

Prospective Analysis of the Impact of Commercialized Hybrid Closed-Loop System on Glycemic Control, Glycemic Variability, and Patient-Related Outcomes in Children and Adults: A Focus on Superiority Over Predictive Low-Glucose Suspend Technology

Open access
Beato-Víbora, Pilar Isabel, Gallego-Gamero, Fabiola, Lázaro-Martín, Lucía, Romero-Pérez, Maria del Mar, Arroyo-Díez, Francisco Javier · 2020 · Diabetes Technology & Therapeutics
Cited by 66

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Background: Automatization of insulin delivery by closed-loop systems represents a major step in type 1 diabetes management. The aim of this study was to analyze the effect of the commercialized hybrid closed-loop system, the MiniMed 670G system, on glycemic control, glycemic variability, and patient satisfaction. Methods: A prospective study, including type 1 diabetes patients consecutively starting on the 670G system in one adult and two pediatric hospitals, was performed. Baseline and 3-month visits were documented. Two weeks of data from the system were downloaded. Glycemic variability measures were calculated. Adults and adolescents completed a set of questionnaires (Gold and Clarke scores, Hypoglycemia Fear Survey, Diabetes Quality of Life [DQoL], Diabetes Treatment Satisfaction [DTS], Diabetes Distress Scale, Pittsburgh Sleep Quality Index). Results: Fifty-eight patients were included (age: 28 ± 15 years [7–63], <18 years old: 38% [ n = 22], 59% [ n = 34] females, previous use of SAP-PLGS [predictive low-glucose suspend]: 60% [ n = 35]). HbA1c was reduced from 57 ± 10 to 53 ± 7 mmol/L (7.4% ± 0.9% to 7.0% ± 0.6%) ( P < 0.001) and time in range 70–180 mg/dL was increased from 63.0% ± 11.4% to 72.7% ± 8.7% ( P < 0.001). In patients with high baseline hypoglycemia risk, time <54 and <70 mg/dL were reduced from 0.9% ± 1.1% to 0.45% ± 0.7% ( P = 0.021) and from 3.3% ± 2.8% to 2.1% ± 2.1% ( P = 0.019), respectively. Glycemic variability measures improved. Time in auto mode was 85% ± 17%, the number of auto mode exits was 0.6 ± 0.3 per day, and the number of alarms was 8.5 ± 3.7 per day. Fear of hypoglycemia, DQoL, DTS, and diabetes distress improved, while the percentage of patients with poor sleep quality was reduced. The discontinuation rate was 3%. Conclusion: The commercialized hybrid closed-loop system improves glycemic control and glycemic variability in children and adults, reducing the burden of living with type 1 diabetes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2019.0400

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 66

Metadata

Authors
Beato-Víbora, P. I., Gallego-Gamero, F., Lázaro-Martín, L., Romero-Pérez, M. D. M., & Arroyo-Díez, F. J.
Venue
Diabetes Technology & Therapeutics
Published
2020-12-01
Volume
22
Issue
12
Pages
912-919
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2995689063
Cited by
66
References
9
FWCI
4.82
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prospective Analysis of the Impact of Commercialized Hybrid Closed-Loop System on Glycemic Control, Glycemic Variability, and Patient-Related Outcomes in Children and Adults: A Focus on Superiority Over Predictive Low-Glucose Suspend Technology. https://app.cochat.ai/papers/10.1089/dia.2019.0400
The paper
Beato-Víbora, P. I., Gallego-Gamero, F., Lázaro-Martín, L., Romero-Pérez, M. D. M., & Arroyo-Díez, F. J. (2020). Prospective Analysis of the Impact of Commercialized Hybrid Closed-Loop System on Glycemic Control, Glycemic Variability, and Patient-Related Outcomes in Children and Adults: A Focus on Superiority Over Predictive Low-Glucose Suspend Technology. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2019.0400

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.