The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Real-World Performance of the MiniMed™ 780G System: First Report of Outcomes from 4120 Users
Open accessAbstract
Background: The MiniMed™ 780G system includes an advanced hybrid closed loop (AHCL) algorithm that provides both automated basal and correction bolus insulin delivery. The preliminary performance of the system in real-world settings was evaluated. Methods: Data uploaded from August 2020 to March 2021 by individuals living in Belgium, Finland, Italy, the Netherlands, Qatar, South Africa, Sweden, Switzerland, and the United Kingdom were aggregated and retrospectively analyzed to determine the mean glucose management indicator (GMI), percentage of time spent within (TIR), below (TBR), and above (TAR) glycemic ranges, system use, and insulin consumption in users having ≥10 days of sensor glucose (SG) data after initiating AHCL. The impact of initiating AHCL was evaluated in a subgroup of users also having ≥10 days of SG data, before AHCL initiation. Results: Users ( N = 4120) were observed for a mean of 54 ± 32 days. During this time, they spent a mean of 94.1% ± 11.4% of the time in AHCL and achieved a mean GMI of 6.8% ± 0.3%, TIR of 76.2% ± 9.1%, TBR <70 of 2.5% ± 2.1%, and TAR >180 of 21.3% ± 9.4%, after initiating AHCL. There were 77.3% and 79.0% of users who achieved a TIR >70% and a GMI of <7.0%, respectively. Users for whom comparison with pre-AHCL was possible ( N = 812) reduced their GMI by 0.4% ± 0.4% ( P = 0.005) and increased their TIR by 12.1% ± 10.5% ( P < 0.0001), post-AHCL initiation. More users achieved the glycemic treatment goals of GMI <7.0% (37.6% vs. 75.2%, P < 0.0001) and TIR >70% (34.6% vs. 74.9%, P < 0.0001) when compared with pre-AHCL initiation. Conclusion: Most MiniMed 780G system users achieved TIR >70% and GMI <7%, while minimizing hypoglycemia, in a real-world condition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Both generation 1 low-glucose-suspend33 and generation 2 hybrid closed-loop systems improve glycated haemoglobin concentrations, the time in target range and the time below target range in children, adolescents34 and adults.35-37”
From Blood glucose monitoring devices: current considerations (2023) · cites this paper as [37]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“AHCL systems continuously adjust basal insulin delivery every five minutes based on real‐time continuous glucose monitoring (CGM) data and automatically administer correction boluses in response to hyperglycemia, thereby facilitating the maintenance of glucose levels near predefined targets 8 .”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237 · cited 1×
“The new parameters are born from the growing use of CGM measurements of time spent in different ranges with consensus on definitions of ranges and current goals.(1) For people with T1DM, except during pregnancy, the goals are to spend >70% of the time between the range of 70–180 mg/dL, <4% below 70 mg/dL, <1% below 54…”
BackgroundSelf-citationState of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016–2018
Foster, N. C., Beck, R. W., Miller, K. M., Clements, M. A., Rickels, M. R., DiMeglio, L. A., Maahs, D. M., Tamborlane, W. V., Bergenstal, R., Smith, E., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0384 · Cited by 1,907
Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030
Comparison of Evidence of Treatment Effects in Randomized and Nonrandomized Studies
Ioannidis, J. P. A. (2001) · JAMA · doi:10.1001/jama.286.7.821 · Cited by 919
Holman, N., Knighton, P., Kar, P., O'Keefe, J., Curley, M., Weaver, A., Barron, E., Bakhai, C., Khunti, K., Wareham, N. J., et al. (2020) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(20)30271-0 · Cited by 908
6. Glycemic Targets: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s006 · Cited by 847
Interpretation and Impact of Real-World Clinical Data for the Practicing Clinician
Blonde, L., Khunti, K., Harris, S. B., Meizinger, C., & SKOLNIK, N. (2018) · Advances in Therapy · doi:10.1007/s12325-018-0805-y · Cited by 757
Glucose management indicator (GMI): a new term for estimating A1C from continuous glucose monitoring
Bergenstal, R. M., Beck, R. W., Close, K. L., Grunberger, G., Sacks, D. B., Kowalski, A., Brown, A. S., Heinemann, L., Aleppo, G., Ryan, D. B., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1581 · Cited by 684 · cited 1×
“Users with ‡10 days of sensor glucose (SG) data after AHCL was enabled for the first time (post-AHCL) were included in the analysis, based on previous publications using a similar duration of time to estimate or determine CGM-derived metrics.(13,14) All data available were included, whether the system was in AHCL cont…”
MethodGarg, S. K., Weinzimer, S. A., Tamborlane, W. V., Buckingham, B. A., Bode, B. W., Bailey, T. S., Brazg, R. L., Ilany, J., Slover, R. H., Anderson, S. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0421 · Cited by 585
Self-citationWeisman, A., Bai, J.-W., Cardinez, M., Kramer, C. K., & Perkins, B. A. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30167-5 · Cited by 463
Flagged first, then by citations
Research works printed but not linked: 3
- Da Silva J, , Arrieta A, , Castaneda J, et al.: Real-world Performance of the MiniMed™ 780G System: impact of initiating automated basal and correction boluses. Diabetes Technol Ther, 2021; 23:A79–A80.
- Habif S, , Singh H, , Manning M, et al.: Quality of life outcomes and glycemic control from the T:slim X2 Pump with Control-IQ Technology—Real World Observations from the CLIO Study. Diabetes Technol Ther, 2021; 23:A-66.
- Da Silva J, , Velado K, , Agrawal P, et al.: Real-life use and performance of the MiniMed™ 670G System in Europe. Diabetes Technol Ther, 2020; 22:A96–A97.
Cited by
Sorted by citations
Items 101–200 of 228
Glycometabolic outcomes in adult type 1 diabetic patients switching to closed-loop systems
Papa, G. F. S., Cannarella, R., Condorelli, R. A., Finocchiaro, C., Calogero, A. E., & Vignera, S. L. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110907 · Cited by 10
Rapid‐acting insulin analogues: Theory and best clinical practice in type 1 and type 2 diabetes
Block, C. E. M. D., Cauwenberghe, J. V., Bochanen, N., & Dirinck, E. L. (2022) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14713 · Cited by 10
van den Heuvel, T. R. A., Kolassa, R., Keuthage, W., Kroeger, J., Ré, R., de Portu, S., Vorrink, L., Shin, J., Castañeda, J., Vigersky, R. A., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231161320 · Cited by 9
Self-citationJancev, M., Snoek, F. J., Frederix, G., Knottnerus, H., Blauw, H., Witkop, M., Moons, K. G. M., van Bon, A. C., DeVries, J. H., Serné, E. H., et al. (2023) · BMJ Open · doi:10.1136/bmjopen-2023-074984 · Cited by 9
12-Month Efficacy of Advanced Hybrid Closed-Loop System in Adult Type 1 Diabetes Patients
Nigi, L., Sareri, G. I., Cataldo, D., & Dotta, F. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0319 · Cited by 9
Fresa, R., Bitterman, O., Cavallaro, V., Filippi, M. D., Dimarzo, D., Mosca, C., Nappi, F., Rispoli, M., & Napoli, A. (2024) · Acta Diabetologica · doi:10.1007/s00592-024-02315-z · Cited by 10
Emerging Technologies and Therapeutics for Type 1 Diabetes
Aktürk, H. K., & McKee, A. M. (2023) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2023.07.002 · Cited by 9
Efficacy of advanced hybrid closed loop systems in cystic fibrosis related diabetes: a pilot study
Bassi, M., Franzone, D., Dufour, F., Spacco, G., Cresta, F., d’Annunzio, G., Tantari, G., Calevo, M. G., Castellani, C., Minuto, N., et al. (2024) · Frontiers in Endocrinology · doi:10.3389/fendo.2024.1347141 · Cited by 8
Excellence in the management of Advanced Hybrid Closed-Loop Systems: Lessons from the Polish cohort
Matejko, B., van den Heuvel, T. R. A., Castañeda, J., Arrieta, A., CYRANKA, K. M., Cohen, O., Małecki, M., & Klupa, T. (2024) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2024.111832 · Cited by 8
Self-citationLiarakos, A. L., Crabtree, T. S. J., Griffin, T. P., Hussain, S., Gallen, G., Elliott, J., Furlong, N. J., Narendran, P., Thabit, H., Leelarathna, L., et al. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2025.0165 · Cited by 10
Evolution of the Artificial Pancreas: Components and Integration—CGMs, Insulin, and AP Systems
Bergenstal, R. M., Heller, A., Breton, M. D., Vigersky, R. A., Brown, S. A., Forlenza, G. P., Sherr, J. L., Hovorka, R., Russell, S. J., Damiano, E. R., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251342239 · Cited by 9
Panagiotou, M., Brigato, L., Streit, V., Hayoz, A., Proennecke, S., Athanasopoulos, S., Olsen, M. T., Brok, E. J. D., Svensson, C. H., Makrilakis, K., et al. (2025) · IEEE Access · doi:10.1109/access.2025.3600738 · Cited by 8
Fagerberg, A., Borch, L., Kristensen, K., & Hjelle, J. S. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0412 · Cited by 8
Quirós, C., Alonso-Carril, N., Rodriguez-Rodríguez, S., Barahona, M. J., Orois, A., Simó-Servat, A., Ramos, M., & Perea, V. (2022) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2022.10.003 · Cited by 8
Quirós, C., Alonso-Carril, N., Rodriguez-Rodríguez, S., Barahona, M. J., Orois, A., Simó-Servat, A., Ramos, M., & Perea, V. (2023) · Endocrinología Diabetes y Nutrición (English ed ) · doi:10.1016/j.endien.2022.10.005 · Cited by 8
Daytime hypoglycemic episodes during the use of an advanced hybrid closed loop system
Rossi, A., Montefusco, L. B., Reseghetti, E., Pastore, I., Rossi, G., Usuelli, V., Loretelli, C., Boci, D., Nasr, M. B., D’Addio, F., et al. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.111011 · Cited by 7
Giannoulaki, P., Kotzakioulafi, E., Nakas, A., Kontoninas, Z., Evripidou, P., & Didangelos, T. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13051441 · Cited by 7
Berget, C., Annan, F., Biester, T., Choudhary, P., Forlenza, G. P., Peters, A. L., Renard, É., & Deiss, D. (2025) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16321 · Cited by 8
Transforming drug and vaccine delivery for equitable access in global health
Yang, X., Zhang, L., Staykov, K., Wu, Z., & Jaklenec, A. (2025) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2025.152415 · Cited by 7
Lee, J., Han, S. Y., & Kwon, Y. W. (2025) · Biosensors · doi:10.3390/bios15080543 · Cited by 8
Bombaci, B., Calderone, M., Pisa, A. D., Rocca, M. L., Torre, A., Lombardo, F., Salzano, G., & Passanisi, S. (2025) · Medicina · doi:10.3390/medicina61091602 · Cited by 11
MiniMed 780G Advanced Hybrid Closed-Loop System Use During Days Without User-Initiated Boluses
Niu, F., Liu, M., Yovanovich, C., Vigersky, R. A., Shin, J. J., & MCVEAN, J. J. F. (2026) · Diabetes Care · doi:10.2337/dc25-2124 · Cited by 7
Self-citationSeget, S., Chobot, A. P., Rusak, E., Ochab, A., Bielawska, A., Polańska, J., & Jarosz-Chobot, P. A. (2023) · Technology and Health Care · doi:10.3233/thc-230490 · Cited by 7
Deepchand, S., Balla, V., Eroukhmanoff, J., Sall, K. L., Romain, B., Lejeune, M., Penfornis, A., & Amadou, C. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0379 · Cited by 7
Piccini, B., Felicioni, M., Pessina, B., Bertini, M., Casalini, E., Ceccotti, C., Fariña, S., Ferrari, M., Lenzi, L., Monzali, F., et al. (2023) · Nutrients · doi:10.3390/nu15234875 · Cited by 7
Renard, É., Tubiana‐Rufi, N., Chaillous, L., Bonnemaison, É., Hanaire, H. P., Bismuth, É., Joubert, M., Coutant, R., Schaepelynck, P., Beltrand, J., et al. (2024) · Médecine des Maladies Métaboliques · doi:10.1016/j.mmm.2024.04.002 · Cited by 7
Lundemose, S. B., McCarthy, O. M., Christensen, M. B., Laugesen, C., Bracken, R. M., Holst, J. J., Ranjan, A. G., & Nørgaard, K. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16103 · Cited by 7
One-year evaluation of automated insulin delivery systems in adults with type 1 diabetes
Pujante, P., García, A. V., Villa-Fernández, E., García‐Villarino, M., González‐Vidal, T., Díaz-Naya, L., Gutiérrez-Buey, G., Veiguela, B., Rivas‐Otero, D., Torre, E. L. M., et al. (2025) · Frontiers in Digital Health · doi:10.3389/fdgth.2025.1596188 · Cited by 6
The DERMIS Study: Methodologies, Results, and Implications for the Future
Hirsch, I. B., Khakpour, D., Joseph, J. I., Shinohara, M. M., Wang, R. K., Klueh, U., Kreutzner, D., Riveline, J., Jacquemier, P., Maier, L. E., et al. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241298005 · Cited by 6
Lin, Y. K., Ye, W., Hepworth, E., Rickels, M. R., Amiel, S. A., Speight, J., & Shaw, J. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgae846 · Cited by 6
Lindkvist, E. B., Ranjan, A. G., Nørgaard, K., & Svensson, J. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2025.0068 · Cited by 6
Artificial pancreas: the past and the future
Kitagawa, H., Munekage, M., Seo, S., & Hanazaki, K. (2025) · Journal of Artificial Organs · doi:10.1007/s10047-025-01510-1 · Cited by 7
Lundemose, S. B., Ranjan, A. G., Nørgaard, O., Suvitaival, T., & Nørgaard, K. (2025) · Diabetes Care · doi:10.2337/dc25-0702 · Cited by 6
Bassi, M., Spacco, G., Pezzotta, F., Jorgi, M. D., Siri, G., Pintabona, A., Calevo, M. G., Minuto, N., & Maghnie, M. (2025) · Frontiers in Endocrinology · doi:10.3389/fendo.2025.1670266 · Cited by 5
Castañeda, J., de Galan, B. E., van Kuijk, S. M. J., Arrieta, A., van den Heuvel, T. R. A., & Cohen, O. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15955 · Cited by 8
Self-citationNigi, L., Batzibal, M. S., Cataldo, D., & Dotta, F. (2024) · Diabetes Therapy · doi:10.1007/s13300-024-01656-w · Cited by 6
Hybrid Closed-Loop Systems to Date: Hype Versus Reality
Messer, L. H., & Berget, C. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0375 · Cited by 6
Benhamou, P., Adenis, A., Lablanche, S., Franc, S., Amadou, C., Penfornis, A., Kariyawasam, D., Beltrand, J., & Charpentier, G. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231186976 · Cited by 6
LUEHRS, T., Kordonouri, O., Berge, T. V. D., Remus, K., Biester, S., Kapitzke, K., Danne, T., Reschke, F., Niemeyer, M., Weiskorn, J., et al. (2025) · Diabetes Technology & Therapeutics · doi:10.1177/15209156251376708 · Cited by 5
Izquierdo, F. J. E., García, M. J. A., Vaquero, A. A. C., Gamero, J. A. L., Gómez-Turégano, P., Andrada, M. L., Pearson, A. C., & Figueredo, R. J. G. (2024) · Endocrinología Diabetes y Nutrición (English ed ) · doi:10.1016/j.endien.2024.03.019 · Cited by 5
The Role, Potential Benefits and Cost-effectiveness of Digital Tools for Diabetes Management
Carlson, A. L., Badlani, S., & Shah, V. N. (2025) · Clinical Therapeutics · doi:10.1016/j.clinthera.2025.05.002 · Cited by 7
Gómez, A. M., Henao, D. C., Múñoz, Ó., Romero-Alvernia, D. M., León, J. D. S., Jaramillo, P. E., Moscoso, E., Parra, D., Robledo, S., Maira, G., et al. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0589 · Cited by 5
The success of insulin pump therapy: importance of education of patients and health professionals
Carić, B., Marin, S., Pančić, J. M., Malešević, G., & Mirnić, D. (2024) · Frontiers in Clinical Diabetes and Healthcare · doi:10.3389/fcdhc.2024.1464365 · Cited by 5
GRAF, S. F., Hofer, G., Hirschmann, R., Lehmann, R., & Cavelti‐Weder, C. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112035 · Cited by 6
Gómez, A. M., Diana Cristina Henao, C., Rebolledo, M., Jaramillo, P., Múñoz, Ó., Laura María Niño, G., & Yepes, C. A. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221108424 · Cited by 5
Mutlu, G. Y., Eviz, E., Can, E., Gökçe, T., Muradoğlu, S., & Hatun, Ş. (2023) · Clinical Diabetology · doi:10.5603/dk.a2022.0063 · Cited by 5
Closed loop insulin delivery–Opportunities and limitations
Weiss, R. (2023) · Journal of Diabetes · doi:10.1111/1753-0407.13490 · Cited by 4
Medina, A. M. G., Henao, D. C., León, J. D. S., González, J. A. G., Múñoz, Ó., Brahim, L. C., Prada, G. A. M., & Rondón, M. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231204376 · Cited by 5
Wang, Q., Li, X., Zhang, W., Wang, H., Tang, J., Ding, Y., Zheng, X., & Luo, S. (2025) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/20420188251350210 · Cited by 4
Conti, M., Gironi, I., Meneghini, E., Mion, E., Vieste, G. D., Bertuzzi, F., & Pintaudi, B. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14248823 · Cited by 4
Evolution of the Artificial Pancreas: Components and Integration—CGMs, Insulin, and AP Systems
Bergenstal, R. M., Heller, A., Breton, M. D., Vigersky, R. A., Brown, S. A., Forlenza, G. P., Sherr, J. L., Hovorka, R., Russell, S. J., Damiano, E. R., et al. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2025.18801.rmb · Cited by 5
Comparison of Metabolic Control in Children and Adolescents Treated with Insulin Pumps
Lejk, A., Myśliwiec, K., Michalak, A., Pernak, B., Fendler, W. M., & Myśliwiec, M. (2024) · Children · doi:10.3390/children11070839 · Cited by 4
Borella, N. D., Ferramosca, A., Castagna, G., Ippolito, S., Ceresoli, S., Taverna, A., Sonzogni, B., Trevisan, R., & Lepore, G. (2024) · Acta Diabetologica · doi:10.1007/s00592-024-02397-9 · Cited by 4
Self-citationSehgal, S., de Bock, M. I., Grosman, B., Williman, J. A., Kurtz, N., Guzman, V., Benedetti, A., Roy, A., Turksoy, K., Juarez, M., et al. (2024) · BMC Endocrine Disorders · doi:10.1186/s12902-024-01709-y · Cited by 4
Successful use of MiniMed 780G during pregnancy
Baagar, K. A. M., Ali, H. A., Al-Mohanadi, D. H., Mohamud, K., Al‐Naimi, N. S., Alsharkawy, N. A. A. S., Othman, E. M. M., & Bashir, M. (2023) · Journal of Clinical and Translational Endocrinology Case Reports · doi:10.1016/j.jecr.2023.100156 · Cited by 3
Inpatient Use of Automated Insulin Delivery Systems
Chadalawada, L., Parab, R., Feeley, J. M., Hughes, M. S., Pasquel, F. J., & Davis, G. M. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251412442 · Cited by 3
Franzone, D., Spacco, G., Piano, A., Siri, G., Tantari, G., d’Annunzio, G., Calevo, M. G., Maghnie, M., Minuto, N., & Bassi, M. (2025) · Frontiers in Endocrinology · doi:10.3389/fendo.2025.1590964 · Cited by 3
Diabetes Without Math as Automation Advances: A Shifting Clinical Paradigm
Mora, P. A., Cook, K. P., & MacLeod, J. (2025) · Diabetes Technology and Obesity Medicine · doi:10.1089/dtom.2025.0033 · Cited by 2
Type 1 Diabetes in 2023 - From Real Practice to Open Questions
Chlup, R. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.100991 · Cited by 1
Atik-Altınok, Y., Mansuroglu, Y., Demir, G., Balkı, H. G., Ozen, S., Darcan, S., & Goksen, D. (2024) · European Journal of Clinical Nutrition · doi:10.1038/s41430-024-01422-y · Cited by 2
Forlenza, G. P., Tabatabai, I., & Lewis, D. M. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0073 · Cited by 2
Pflaum, R., Vaduva, P., Allard, M., Derrien, C., Lefebvre, M.-A., Esvan, M., Guilhem, I., & Guénégo, A. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241266826 · Cited by 2
Kessler, L., Thivolet, C. H., Penfornis, A., Gouet, D., Coffin, C., Moret, M., Borot, S., Bekka, S., Sonnet, E., Joubert, M., et al. (2024) · Diabetes Therapy · doi:10.1007/s13300-024-01673-9 · Cited by 2
Self-citationAmuedo, S., Bellido, V., Cruz, M. Á. M., Herguido, N. G., Gallardo, G. L., Pérez-Morales, A., & Moreno, A. S. (2022) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2022.09.117 · Cited by 2
Guzmán-Gómez, G. E., Fériz, K., Pico, V. M. B., Guerra, M. A., Arias‐Valderrama, O., Marin-Betancourth, V., & García-Trujillo, A. O. (2023) · Endocrine and Metabolic Science · doi:10.1016/j.endmts.2023.100139 · Cited by 2
Jendle, J., Buompensiere, M. I., Holm, A. L., de Portu, S., Malkin, S. J. P., & Cohen, O. (2022) · Diabetes Therapy · doi:10.1007/s13300-022-01252-w · Cited by 2
Self-citationFushimi, E., Bianchi, F. D., Battista, H. D., & Garelli, F. (2025) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2025.05.004 · Cited by 1
Artificial Pancreas: The First 20 Years
Doyle, F. J., & Kovatchev, B. P. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251330920 · Cited by 1
Automated Insulin Delivery Beyond Glycemic Outcomes: Endpoints and Evidence
Jones, H. C., Trawley, S. L., Jenkins, A. J., MacIsaac, R. J., Kong, Y. W., Morrison, D., & O'Neal, D. N. (2025) · Diabetes Technology & Therapeutics · doi:10.1177/15209156251390831 · Cited by 1
Benhamou, P., Vesin, A., Reynaud, L., & Chatel, B. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251404493 · Cited by 1
Šantová, A., Plachý, L., Neuman, V., Amaratunga, S. A., Slavenko, M. G., Obermannová, B., Drnkova, L., Průhová, Š., & Šumnı́k, Z. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156251415187 · Cited by 1
Mekki, Y. M., Park, J., Alzaareer, Z., Hussain, Z., Gulzar, A., Elzouki, A. Y. A., Güemes, A., & Zughaier, S. M. (2026) · Journal of Diabetes & Metabolic Disorders · doi:10.1007/s40200-026-01876-w · Cited by 1
Bjerrekær, J., Berg, A. K., Christensen, M. H., Suvitaival, T., Nørgaard, K., & Svensson, J. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156261433362 · Cited by 1
Papa, G., Cannarella, R., Finocchiaro, C., Anzaldi, M., Gusmano, C., Palazzolo, R., Gruttadauria, G., Patti, L., Presti, D. L., Calabrisotto, S. S., et al. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261446967 · Cited by 1
SISTEMAS AUTOMÁTICOS DE ADMINISTRACIÓN DE INSULINA: MITOS, LEYENDAS Y GESTIÓN DEL SANTO GRIAL
Mesa, A., & Conget, I. (2023) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2023.01.002 · Cited by 1
Automated insulin delivery systems: Myths, legends and management of the Holy Grail
Mesa, A., & Conget, I. (2023) · Endocrinología Diabetes y Nutrición (English ed ) · doi:10.1016/j.endien.2023.01.002 · Cited by 1
Jurado, A. L., López‐Siguero, J. P., Gómez‐Perea, A., Jiménez, A. B. A., Becerra‐Paz, I., Ceballos, L. T., Ponce, C. C., Hinojosa, J. M. J., Morcillo, S., & Gea, I. L. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12216951 · Cited by 2
Lyons, R. E., Wahab, R. A., Goh, S. Y., Breen, C., Rhynehart, A., O'Scannail, M., Kelly, H. J., Neff, K., O'Shea, D. B., Canavan, R. J., et al. (2024) · Endocrinology Diabetes & Metabolism · doi:10.1002/edm2.469 · Cited by 1
Romero, P. E., Güemes, M., Guijo, B., Martos‐Moreno, G. Á., Román, J. P., & Argente, J. (2024) · Endocrinología Diabetes y Nutrición (English ed ) · doi:10.1016/j.endien.2024.11.010 · Cited by 3
Bojoga, I., Ioacără, S., Malinici, E. A., Chiper, V., Georgescu, O., Sîrbu, A. M., & Fica, S. V. (2024) · Pediatric Reports · doi:10.3390/pediatric16040100 · Cited by 1
Dosing Algorithms for Insulin Pumps
Çınar, A. (2025) · Diabetes Spectrum · doi:10.2337/dsi25-0004 · Cited by 1
León, J. D. S., & Medina, A. M. G. (2022) · Revista Colombiana de Endocrinología Diabetes & Metabolismo · doi:10.53853/encr.9.4.758 · Cited by 1
New Contributions Towards Meal and Exercise Announcement-Free Artificial Pancreas Systems
Sala-Mira, I. (2023) · RiuNet (Universitat Politècnica de València) · doi:10.4995/thesis/10251/192684 · Cited by 1
Artificial Pancreas: The First 20 Years*
Doyle, F. J., & Kovatchev, B. P. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2025.0134 · Cited by 2
Takagi, E., Kaga, H., Mori, R., Fujikawa, S., Nagashima, H., Kogai, T., Koshibu, M., Sato, J., Nishida, Y., Ikeda, F., et al. (2026) · Journal of Diabetes Investigation · doi:10.1111/jdi.70463
“AHCL systems continuously adjust basal insulin delivery every fi ve minutes based on real-time continuous glucose monitoring (CGM) data and automatically administer correction boluses in response to hyperglycemia, thereby facilitating the maintenance of glucose levels near prede fi ned targets 8 .”
JENDLE, J. H. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221091842
Advanced hybrid closed loop on the Polish market
Seget, S., Tekielak, A., Rusak, E., & Jarosz-Chobot, P. A. (2022) · Pediatria Polska · doi:10.5114/polp.2022.123916
Eine neue Welt: Verbesserung der Diabetestherapie durch digitale und technische Innovationen
Menzen, M. (2023) · DMW - Deutsche Medizinische Wochenschrift · doi:10.1055/a-1911-2926
Benefits of Implementation of Insulin Pump in People with Type 1 Diabetes: 10 Case Reports
Nováková, N., Nezval, M., & Robenková, M. A. (2023) · IntechOpen eBooks · doi:10.5772/intechopen.110073
Current Treatment of Pediatric Type 1 Diabetes
Suzuki, J. (2023) · Journal of Nihon University Medical Association · doi:10.4264/numa.82.3_143
Elhenawy, Y. I., Shaarawy, M. A., & Selim, E. M. (2023) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem-2023-0250
Newest and most promising Type 1 Diabetes treatment
Banatwala, U. E. S., Imran, R., & Taufiq, M. U. (2023) · Journal of the Pakistan Medical Association · doi:10.47391/jpma.9916
Hanaire, H. P., Naïditch, N., Melki, V., Morcel, P., Puech-Bret, N., Scharbarg, E., Godàs, R. T., Lancman, G., Schaller, M., Delval, C., et al. (2023) · EMJ Diabetes · doi:10.33590/emjdiabet/10303508
Badnjević-Čengić, A., Čerim-Aldobašić, A., Hodžić, M., & Dautbegović-Stevanović, D. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-49068-2_20
Az automata inzulinpumpa gyakorlati használata
Kis, J. T., Kiss, K. A., Fekete, C., Schandl, L., & Winkler, G. (2023) · Diabetologia Hungarica · doi:10.24121/dh.2023.5
Current and Emerging Technologies for the Diagnosis and Treatment of Diabetes Mellitus
Kollman, P., & Burke, E. (2024) · Current Emergency and Hospital Medicine Reports · doi:10.1007/s40138-024-00281-y
Izquierdo, F. J. E., García, M. J. A., Vaquero, A. A. C., Gamero, J. A. L., Gómez-Turégano, P., Andrada, M. L., Pearson, A. C., & Figueredo, R. J. G. (2024) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2024.03.002
McDonnell, D. J., Smith, D., & Forde, H. E. (2024) · Diabetic Medicine · doi:10.1111/dme.15391
Owaydah, A., Abouglila, K., & Liloglou, T. (2024) · Ibnosina Journal of Medicine and Biomedical Sciences · doi:10.1055/s-0044-1787111
Romero, P. E., Güemes, M., Guijo, B., Martos‐Moreno, G. Á., Román, J. P., & Argente, J. (2024) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2024.07.002
Metadata
- Authors
- Silva, J. D., Lepore, G., Battelino, T., Arrieta, A., Castañeda, J., Grossman, B., Shin, J., & Cohen, O.
- Affiliations
- Medtronic (Switzerland) (CH)
- Ospedale Papa Giovanni XXIII (IT)
- University of Ljubljana (SI)
- Medtronic (Netherlands) (NL)
- Medtronic, Northridge, California, USA.
- Medtronic (United States) (US)
- Corresponding author
- Cohen, Ohad
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2022-01-31
- Volume
- 24
- Issue
- 2
- Pages
- 113-119
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- PMC
- PMC8817690
- OpenAlex
- W3201039184
- Cited by
- 229
- References
- 26
- Citations by year
- 2026: 29 · 2025: 35 · 2024: 61 · 2023: 67 · 2022: 36
- FWCI
- 30.80
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Diabetes Technology & Therapeutics (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- MiniMed 780G, hybrid closed-loop insulin delivery, type 1 diabetes, real-world performance, glucose management indicator, time in range, glycemic control, continuous glucose monitoring
- MeSH terms
- Blood Glucose, Diabetes Mellitus, Type 1, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Retrospective Studies, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review