The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Ultrasound-Mediated Transfection of Mammalian Cells
Abstract
Mammalian cells were successfully transfected with plasmid DNA in vitro using ultrasound transmitted through the walls of cell culture flasks or plates. Primary rat fibroblasts or chondrocytes were exposed to ultrasound in the presence of plasmids containing lacZ or neo genes. The transfection efficiency was evaluated by counting the number of β-galactosidase (β-Gal) positive cells or neomycin-resistant colonies. Transfection efficiency was optimized by varying ultrasound conditions, ambient temperatures (room temperature or 37°C), plasmid concentrations, and initial cell populations. Additional experiments were performed to elucidate the mechanism of the ultrasound-mediated transfection. Maximal gene transfection was seen with two ultrasound conditions: 1-MHz carrier frequency 411 ± 189 kPascal continuous wave with 20 or 30 sec of exposure time, and 1 MHz carrier frequency 319 ± 157 kPascal continuous wave with 40 or 60 sec of exposure time. Gene expression was negligible when transfection procedures were performed at room temperature. The average stable transfection rate was 0.34% of surviving cells with a plasmid concentration of 40 μg/ml in primary fibroblasts. The transient transfection rate was 2.4% of surviving cells for primary chondrocytes. Data suggest that increasing plasmid concentration will increase efficiency. Identical treatment with 3.5 MHz produced no transfection, implying that cavitation produced by the ultrasound pressure wave appeared to play a critical role in mediating transfection. Ultrasound-mediated transfection was effective for suspended cells as well as for plated cells. This transfection method is simple, easy to keep sterile, and convenient. Ultrasound-mediated transfection appears to be a promising method for gene transfer into mammalian cells. Transfection of mammalian cells in vitro would be enhanced if the method could be applied directly to culture dishes or flasks without replating and transferring cells or introducing probes or other devices into the culture medium. Kim et al. have developed a method that uses ultrasonic waves to transfect plasmids into fibroblasts, chondrocytes, and presumably other mammalian cells. They report that ultrasonic power and duration, ambient temperature, and plasmid concentration are critical to achieving maximal expression, whereas initial cell density is less important. They show that cavitation is a key component of ultrasound-mediated transfection. Stable transfection of fibroblasts resulted in marker gene expression in 0.34% of the surviving fibroblasts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-efficiency transformation of mammalian cells by plasmid DNA.
Chen, C., & Okayama, H. (1987) · Molecular and Cellular Biology · doi:10.1128/mcb.7.8.2745 · Cited by 5,373
The Basic Science of Gene Therapy
Mulligan, R. C. (1993) · Science · doi:10.1126/science.8493530 · Cited by 1,741
ULTRASOUND: Its Chemical, Physical and Biological Effects
Suslick, K. S., & Nyborg, W. L. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.398864 · Cited by 1,094
Zhou, X., & Huang, L. (1994) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(94)90066-3 · Cited by 495
Transfection of mammalian cells with plasmid DNA by scrape loading and sonication loading.
Fechheimer, M., Boylan, J. F., Parker, S., Sisken, J. E., Patel, G. L., & Zimmer, S. G. (1987) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.84.23.8463 · Cited by 315
Sawicki, M. P., Samara, G., Hurwitz, M., & Passaro, E. (1993) · The American Journal of Surgery · doi:10.1016/s0002-9610(05)80522-7 · Cited by 226
Safety and Short-Term Toxicity of a Novel Cationic Lipid Formulation for Human Gene Therapy
San, H., Yang, Z.-Y., Pompili, V. J., Jaffe, M. L., Plautz, G. E., Xu, L., Felgner, J. H., Wheeler, C. J., Felgner, P. L., Gao, X., et al. (1993) · Human Gene Therapy · doi:10.1089/hum.1993.4.6-781 · Cited by 174
Philip, R., Brunette, E., Kilinski, L., Murugesh, D. K., McNally, M. A., Uçar, K., Rosenblatt, J. D., OKARMA, T. B., & LEBKOWSKI, J. S. (1994) · Molecular and Cellular Biology · doi:10.1128/mcb.14.4.2411-2418.1994 · Cited by 117
Legendre, J., & Szoka, F. C. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.3.893 · Cited by 98
Crum, L. A., Roy, R. A., Dinno, M. A., et al. (1992) · The Journal of the Acoustical Society of America · doi:10.1121/1.402638 · Cited by 85
Cited by
Viral and nonviral delivery systems for gene delivery
Nayerossadat, N., Maedeh, T., & Ali, P. (2012) · Advanced Biomedical Research · doi:10.4103/2277-9175.98152 · Cited by 858
Intracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts
Stewart, M. P., Langer, R., & Jensen, K. F. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00678 · Cited by 747
Therapeutic applications of ultrasound
ter Haar, G. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.005 · Cited by 721
Nonviral Gene Delivery: Principle, Limitations, and Recent Progress
Al-Dosari, M. S., & Gao, X. (2009) · The AAPS Journal · doi:10.1208/s12248-009-9143-y · Cited by 706
Mammalian cell transfection: the present and the future
Kim, T. K., & Eberwine, J. H. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3821-6 · Cited by 678
Transfection of a reporter plasmid into cultured cells by sonoporation in vitro
Bao, S., Thrall, B. D., & Miller, D. L. (1997) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00025-2 · Cited by 504
Gene therapy and DNA delivery systems
Ibraheem, D., Elaissari, A., & Fessi, H. (2014) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2013.11.041 · Cited by 454
Nonviral gene delivery: What we know and what is next
Gao, X., Kim, K.-S., & Liu, D. (2007) · The AAPS Journal · doi:10.1208/aapsj0901009 · Cited by 431
Physical methods for gene transfer: Improving the kinetics of gene delivery into cells
MEHIERHUMBERT, S., & GUY, R. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.12.007 · Cited by 395
Plasma membrane poration induced by ultrasound exposure: Implication for drug delivery
Mehier-Humbert, S., Bettinger, T., Yan, F., & Guy, R. H. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.01.007 · Cited by 360
Artificial Cavitation Nuclei Significantly Enhance Acoustically Induced Cell Transfection
Greenleaf, W. J., Bolander, M. E., Sarkar, G., Goldring, M. B., & Greenleaf, J. F. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00003-9 · Cited by 359
Self-citationMicrobubble-enhanced ultrasound for vascular gene delivery
Lawrie, A., Brisken, A., Francis, S., Cumberland, D., Crossman, D., & Newman, C. (2000) · Gene Therapy · doi:10.1038/sj.gt.3301339 · Cited by 343
Liposomes in ultrasonic drug and gene delivery
Huang, S.-L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.003 · Cited by 339
Biological effects of ultrasound: Development of safety guidelines. Part II: General review
Nyborg, W. L. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00333-1 · Cited by 306
Targeted delivery of gas-filled microspheres, contrast agents for ultrasound imaging
Klibanov, A. (1999) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00104-5 · Cited by 283
An Experimental and Theoretical Analysis of Ultrasound-Induced Permeabilization of Cell Membranes
Sundaram, J., Mellein, B. R., & Mitragotri, S. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)70034-4 · Cited by 281
Targeted tissue transfection with ultrasound destruction of plasmid-bearing cationic microbubbles
Christiansen, J. P., French, B. A., Klibanov, A. L., Kaul, S., & Lindner, J. R. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)00976-1 · Cited by 273
Efficient Transfection Method for Primary Cells
Hamm, A., Krott, N., Breibach, I., Blindt, R., & Bosserhoff, A. K. (2002) · Tissue Engineering · doi:10.1089/107632702753725003 · Cited by 271
Advances in Gene Delivery Systems
Kamimura, K., Suda, T., Zhang, G., & Liu, D. (2011) · Pharmaceutical Medicine · doi:10.1007/bf03256872 · Cited by 124
Metadata
- Authors
- Kim, H. J., Greenleaf, J. F., Kinnick, R. R., Bronk, J. T., & Bolander, M. E.
- Venue
- Human Gene Therapy
- Publisher
- SAGE Publications
- Published
- 1996-07-10
- Volume
- 7
- Issue
- 11
- Pages
- 1339-1346
- ISSN
- 1043-0342 (ISSN-L)
- 1557-7422
- OpenAlex
- W2091306126
- Cited by
- 337
- References
- 13
- FWCI
- 6.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.