Lung Deposition of BDP/Formoterol HFA pMDI in Healthy Volunteers, Asthmatic, and COPD Patients
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
BACKGROUND: When inhaling medication, it is essential that drug particles are delivered to all sites of lung inflammation, including the peripheral airways. The aim of this study was to assess the lung deposition and lung distribution of beclomethasone dipropionate (BDP)/formoterol (100/6 microg), both dissolved in hydrofluoroalkane (HFA) and delivered by pressurized metered dose inhaler (pMDI) in healthy subjects, asthmatic, and chronic obstructive pulmonary disease (COPD) patients, to investigate how the in vitro characteristics of the formulation translate into the in vivo performance in diseases with different airway obstruction. METHODS: Healthy volunteers (n = 8), persistent asthmatics (n = 8), and patients with stable COPD (n = 8) completed this open-label, single-dose parallel-group study. Each patient received one single treatment of four puffs of (99 m)Tc-labeled BDP/formoterol formulation. The correlation between particle size distribution of radioactivity and of the drugs in the radiolabeled formulation was validated. Intra- and extrapulmonary deposition, amount of exhaled drug, and the central to peripheral ratio (C/P) were calculated immediately after inhalation. Patients' lung function and pharmacokinetic parameters were also assessed up to 24 h post-dose. RESULTS: The average lung deposition of BDP/formoterol was 34.08 +/- 9.30% (relative to nominal dose) in healthy subjects, 30.86 +/- 8.89% in asthmatics, and 33.10 +/- 8.90% in COPD patients. Extrathoracic deposition was 53.48% +/- 8.95, 57.64% +/- 9.92 and 54.98% +/- 7.01, respectively. C/P ratios of 1.42 +/- 0.32 in healthy subjects, 1.96 +/- 0.43 in asthmatics, and 1.94 +/- 0.69 for COPD patients confirmed drug distribution to all regions of the lungs. Forced expiratory volume in 1 sec (FEV(1)) increased in all groups after BDP/formoterol inhalation, but was more evident in the patient groups. No significant correlation between baseline lung function and drug deposition was observed. Formoterol, BDP, and beclomethasone 17 monopropionate (B17MP) plasma profiles were comparable between groups. CONCLUSION: Inhalation of BDP/formoterol HFA (100/6 microg) produces high and homogeneous deposition of BDP and formoterol in the airways, regardless of pathophysiological condition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vestbo, J., Hurd, S. S., Agustí, A. G., Jones, P. W., Vogelmeier, C., Anzueto, A., Barnes, P. J., Fabbri, L. M., Martinez, F. J., Nishimura, M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201204-0596pp · Cited by 15,983
The Nature of Small-Airway Obstruction in Chronic Obstructive Pulmonary Disease
Hogg, J. C., Chu, F., Utokaparch, S., Woods, R., Elliott, W. M., Buzatu, L., Cherniack, R. M., Rogers, R. M., Sciurba, F. C., Coxson, H. O., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032158 · Cited by 3,782 · cited 2×
“(11) Second, corticosteroid receptors and b 2 -adrenergic receptors are present throughout the air-ways; (31, 32) thus, the ICS = LABA synergistic interaction at the molecular level might occur at various cellular types in the lungs.”
Inhaled Glucocorticoids for Asthma
Barnes, P. J. (1995) · New England Journal of Medicine · doi:10.1056/nejm199503303321307 · Cited by 629
Regional Lung Deposition and Bronchodilator Response as a Function of β 2 -Agonist Particle Size
Usmani, O. S., Biddiscombe, M. F., & Barnes, P. J. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200410-1414oc · Cited by 578
Inflammation of small airways in asthma☆☆☆★★★
Hamid, Q., Song, Y., Kotsimbos, T. C., Minshall, E., Bai, T. R., Hegele, R. G., & Hogg, J. C. (1997) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(97)70193-3 · Cited by 548 · cited 2×
“Inhalation of smaller drug particles leads to increased total lung deposition, farther distal airway penetration, and more peripheral lung deposition,((9)) which would be beneficial for asthmatic and COPD patients since the peripheral airways are an important site of inflammation in both diseases.((10,11)) An extrafin…”
Leach, C., Davidson, P., & Boudreau, R. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12061346 · Cited by 430 · cited 2×
“(26,27) In mild asthmatics, lung deposition of extrafine BDP–HFA from a breath-activated device (Autohaler (cid:1) ) was 60% of the emitted dose (48% of the nominal dose) compared to 56–59% of the emitted dose (45–47% of the nominal dose) for patients using a pMDI.”
Newman, S. P., Weisz, A. W., Talaee, N., & Clarke, S. W. (1991) · Thorax · doi:10.1136/thx.46.10.712 · Cited by 326
Inappropriate inhaler use: assessment of use and patient preference of seven inhalation devices
LENNEY, J., INNES, J. A., & CROMPTON, G. K. (2000) · Respiratory Medicine · doi:10.1053/rmed.1999.0767 · Cited by 266
Busse, W. W., Brazinsky, S., Jacobson, K., Stricker, W., Schmitt, K., Vanden Burgt, J., Donnell, D., Hannon, S., & Colice, G. L. (1999) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(99)70016-3 · Cited by 260 · cited 1×
“5-fold lower than the conventional BDP chlorofluorocarbon (CFC) product: 400 mg BDP extrafine was clinically equivalent to 1000 mg of the reference BDP CFC formulation.((14,15)) Each actuation of BDP=formoterol (100=6mg) delivers 86.”
Principles of Metered-Dose Inhaler Design
Newman, S. P. (2005) · Respiratory Care · doi:10.4187/respcare.05501177 · Cited by 244 · cited 1×
“(8) Inhalation of smaller drug particles leads to increased total lung deposition, farther distal airway penetration, and more peripheral lung deposition, (9) which would be beneficial for asthmatic and COPD patients since the peripheral airways are an important site of inflammation in both diseases.”
Leach, C. L., Davidson, P. J., Hasselquist, B. E., & Boudreau, R. J. (2002) · Chest · doi:10.1378/chest.122.2.510 · Cited by 231
Glucocorticoid receptor localization in normal and asthmatic lung.
Adcock, I. M., Gilbey, T., Gelder, C. M., Chung, K. F., & Barnes, P. J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.3.8810618 · Cited by 171 · cited 1×
“(11) Second, corticosteroid receptors and b 2 -adrenergic receptors are present throughout the air-ways; (31, 32) thus, the ICS = LABA synergistic interaction at the molecular level might occur at various cellular types in the lungs.”
Clinical consequences of inadequate inhalation technique in asthma therapy.
Lindgren, S., Bake, B., & Larsson, S. (1987) · PubMed · Cited by 141
Lung function and asthma control with beclomethasone and formoterol in a single inhaler
Huchon, G., MAGNUSSEN, H., Чучалин, А. Г., Dymek, L., Bonnet-Gonod, F., & Bousquet, J. J. (2008) · Respiratory Medicine · doi:10.1016/j.rmed.2008.09.002 · Cited by 139 · cited 2×
“(17) Although the clinical efficacy of the fixed extrafine combination of BDP = formoterol has been established in a number of studies, (18–20) its lung deposition pattern has never been investigated.”
Beclomethasone/formoterolversusbudesonide/formoterol combination therapy in asthma
Papi, A. A., Paggiaro, P., Nicolini, G., Vignola, A. M., & Fabbri, L. M. (2006) · European Respiratory Journal · doi:10.1183/09031936.00095906 · Cited by 139
Beclomethasone/formoterol vs fluticasone/salmeterol inhaled combination in moderate to severe asthma
Papi, A. A., Paggiaro, P. L., Nicolini, G., Vignola, A. M., Fabbri, L. M., & ICAT SE study group (2007) · Allergy · doi:10.1111/j.1398-9995.2007.01493.x · Cited by 133
Methods to identify drug deposition in the lungs following inhalation
Chrystyn, H. (2001) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.2001.01304.x · Cited by 113 · cited 3×
“(22,23) This was also confirmed in a previous study investigating the systemic exposure of BDP = formoterol HFA pMDI before and after charcoal block administration, which is a well-recognized technique able to prevent oral absorption without influencing lung absorption.”
Leach, C., Davidson, P. J., Hasselquist, B. E., & Boudreau, R. J. (2005) · Journal of Aerosol Medicine · doi:10.1089/jam.2005.18.379 · Cited by 105 · cited 3×
“This percentage fell to 37% of the emitted dose (30% of the nominal dose) in subjects with poor inhalation technique.((26,28)) The lung deposition of extrafine formoterol HFA in healthy volunteers, asthmatic, and COPD patients has previously been reported as 31, 34, and 35% of the nominal dose, respectively.”
InfluentialAcerbi, D., Brambilla, G., & Kottakis, I. (2006) · Pulmonary Pharmacology & Therapeutics · doi:10.1016/j.pupt.2006.05.005 · Cited by 71 · cited 1×
“(13) For the same clinical effect, with BDP = formoterol HFA extrafine, the BDP dose is 2.5-fold lower than the conventional BDP chlorofluorocarbon (CFC) product: 400 m g BDP extrafine was clinically equivalent to 1000 m g of the reference BDP CFC formulation.”
InfluentialSelf-citationFabbri, L. M., Nicolini, G., Olivieri, D., & Papi, A. A. (2008) · Expert Opinion on Pharmacotherapy · doi:10.1517/14656566.9.3.479 · Cited by 57
Profita, M., Gagliardo, R. P., GIORGI, R. D., Pompeo, F., Gjomarkaj, M., Nicolini, G., Bousquet, J. J., & Vignola, A. M. (2005) · Allergy · doi:10.1111/j.1398-9995.2005.00702.x · Cited by 55
Descalzi, D., Folli, C., Nicolini, G., Riccio, A., Gamalero, C., Scordamaglia, F., & Canonica, G. W. (2007) · Allergy · doi:10.1111/j.1398-9995.2007.01582.x · Cited by 43
Utility of exhaled nitric oxide as a noninvasive biomarker of lung inflammation in a disease model
Birrell, M. A., McCluskie, K., Hardaker, E. L., Knowles, R. G., & Belvisi, M. (2006) · European Respiratory Journal · doi:10.1183/09031936.00048506 · Cited by 38
Bousquet, J., Poli, G., Acerbi, D., Monno, R., Ramael, S., & Nollevaux, F. (2009) · Clinical Pharmacokinetics · doi:10.2165/00003088-200948060-00001 · Cited by 26
Self-citationSingh, D., Piccinno, A., Borrill, Z., Poli, G., Acerbi, D., Meuleners, L., & Woodcock, A. A. (2008) · Pulmonary Pharmacology & Therapeutics · doi:10.1016/j.pupt.2008.01.001 · Cited by 19
Self-citation
Cited by
Vestbo, J., Papi, A., Corradi, M., Blazhko, V., Montagna, I., Francisco, C., Cohuet, G., Vezzoli, S., Scuri, M., & Singh, D. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30188-5 · Cited by 425
Pulmonary drug delivery by powder aerosols
Yang, M. Y., Chan, J. G. Y., & Chan, H.-K. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.04.055 · Cited by 169
Metadata
- Authors
- De Backer, W., Devolder, A., Poli, G., Acerbi, D., Monno, R., Herpich, C., Sommerer, K., Meyer, T., & Mariotti, F.
- Venue
- Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Publisher
- SAGE Publications
- Published
- 2010-06
- Volume
- 23
- Issue
- 3
- Pages
- 137-148
- ISSN
- 1941-2703 (ISSN-L)
- 1941-2711
- OpenAlex
- W2085195759
- Cited by
- 171
- References
- 25
- FWCI
- 9.59
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.