The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Improved airway targeting with the CFC-free HFA-beclomethasone metered-dose inhaler compared with CFC-beclomethasone
Open accessAbstract
Hydrofluoroalkane-134a (HFA) beclomethasone dipropionate (BDP) was formulated in a metered-dose inhaler (MDI) to deliver a particle size of 1.1 microm compared with 35 microns for currently marketed chlorofluorocarbon (CFC)-BDP products. Two phase I single-dose human deposition studies were conducted using technetium 99m-radiolabelled BDP in a press-and-breathe actuator without an add-on spacer. A healthy volunteer study (n=6) showed that 55-60% of the HFA-BDP ex-actuator dose was deposited in the lungs, with 29-30% deposited in the oropharynx. CFC-BDP deposition was 4-7% in the lungs and 90-94% in the oropharynx. The pattern of deposition within the lung showed that HFA-BDP was spread diffusely throughout the lung airways, whereas CFC-BDP was confined to the central airways with little, if any, peripheral airway deposition. A second study with asthmatics (n=16) confirmed that 56% of the HFA-BDP dose was deposited in the airways, with 33% in the oropharynx. In conclusion, hydrofluoroalkane-134a-beclomethasone dipropionate deposition was much greater in the airways than chlorofluorocarbon-beclomethasone dipropionate, with a concomitant reduction in oropharyngeal deposition. The increased lung deposition efficiency of the hydrofluoroalkane propellant has led to a reduction in the amount of beclomethasone dipropionate needed to achieve a similar efficacy. The penetration of the hydrofluoroalkane to the small airways may provide asthma treatment not afforded by conventional chlorofluorocarbons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inhaled Glucocorticoids for Asthma
Barnes, P. J. (1995) · New England Journal of Medicine · doi:10.1056/nejm199503303321307 · Cited by 629
Alveolar tissue inflammation in asthma.
Kraft, M., Djukanovic, R., Wilson, S., Holgate, S. T., & Martin, R. J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.5.8912772 · Cited by 573
Intercomparison of experimental regional aerosol deposition data
STAHLHOFEN, W., RUDOLF, G., & JAMES, A. C. (1989) · Journal of Aerosol Medicine · doi:10.1089/jam.1989.2.285 · Cited by 423
Deposition and Retention Models for Internal Dosimetry of the Human Respiratory Tract
(1966) · Health Physics · doi:10.1097/00004032-196602000-00005 · Cited by 312
Borgstrom, L., Bondesson, E., Moren, F., Trofast, E., & Newman, S. (1994) · European Respiratory Journal · doi:10.1183/09031936.94.07010069 · Cited by 289
Glucocorticoid receptor localization in normal and asthmatic lung.
Adcock, I. M., Gilbey, T., Gelder, C. M., Chung, K. F., & Barnes, P. J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.3.8810618 · Cited by 171
Scintigraphic assessment of therapeutic aerosols.
Newman, S. P. (1993) · PubMed · Cited by 95
Cited by
Influence of particle size on regional lung deposition – What evidence is there?
Carvalho, T. C., Peters, J. I., & Williams III, R. O. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.12.040 · Cited by 614
Wenzel, S. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200409-1181pp · Cited by 309
The Inhalation of Drugs: Advantages and Problems
Rau, J. L. (2005) · Respiratory Care · doi:10.4187/respcare.05500367 · Cited by 279
Busse, W. W., Brazinsky, S., Jacobson, K., Stricker, W., Schmitt, K., Vanden Burgt, J., Donnell, D., Hannon, S., & Colice, G. L. (1999) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(99)70016-3 · Cited by 260
Dry powder inhalers for pulmonary drug delivery
Frijlink, H. W., & De Boer, A. H. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.67 · Cited by 259
Metadata
- Authors
- Leach, C., Davidson, P., & Boudreau, R.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1998-12-01
- Volume
- 12
- Issue
- 6
- Pages
- 1346-1353
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W1986186916
- Cited by
- 430
- References
- 7
- FWCI
- 16.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved airway targeting with the CFC-free HFA-beclomethasone metered-dose inhaler compared with CFC-beclomethasone. https://app.cochat.ai/papers/10.1183/09031936.98.12061346
- The paper
- Leach, C., Davidson, P., & Boudreau, R. (1998). Improved airway targeting with the CFC-free HFA-beclomethasone metered-dose inhaler compared with CFC-beclomethasone. European Respiratory Journal. https://doi.org/10.1183/09031936.98.12061346
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.