The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Exo-Glove Poly II: A Polymer-Based Soft Wearable Robot for the Hand with a Tendon-Driven Actuation System
Abstract
This article presents Exo-Glove Poly (EGP) II, a soft wearable robot for the hand with a glove that is completely constructed of polymer materials and that operates through tendon-driven actuation for use in spinal cord injury (SCI). EGP II can restore the ability to pinch and grasp any object for people with SCI in daily life. The design of the glove allows it to be compact and extends the range of hand sizes that can fit. A passive thumb structure was developed to oppose the thumb for improved grasping. To increase the robustness of the glove, EGP II was designed to have a minimal number of components using a single material. A kinematic model of the system was used to optimize the design parameters of an antagonistic tendon routing system on a single actuator for various hand sizes and repeated actuations. Experiments were conducted on two subjects with SCI to verify the grasping performance of EGP II. EGP II has a compact glove and an actuation system that can be placed on a desk or wheelchair, with the weights of 104 g and 1.14 kg, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Soft robotic glove for combined assistance and at-home rehabilitation
Polygerinos, P., Wang, Z., Galloway, K. C., Wood, R. J., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.014 · Cited by 1,617
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
THE RESTORATION OF MOTOR FUNCTION FOLLOWING HEMIPLEGIA IN MAN
TWITCHELL, T. E. (1951) · Brain · doi:10.1093/brain/74.4.443 · Cited by 940
Snoek, G. J., IJzerman, M. J., Hermens, H. J., Maxwell, D., & Biering-Sorensen, F. (2004) · Spinal Cord · doi:10.1038/sj.sc.3101638 · Cited by 523
Current hand exoskeleton technologies for rehabilitation and assistive engineering
Heo, P., Gu, G. M., Lee, S.-J., Rhee, K., & Kim, J. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0107-2 · Cited by 517
Exo-Glove: A Wearable Robot for the Hand with a Soft Tendon Routing System
In, H., Kang, B. B., Sin, M., & Cho, K.-J. (2015) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2362863 · Cited by 473
Self-citationYap, H. K., Khin, P. M., Koh, T. H., Sun, Y., Liang, X., Lim, J. H., & Yeow, C.-H. (2017) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2017.2669366 · Cited by 277
Connelly, L., Jia, Y., Toro, M. L., Stoykov, M. E., Kenyon, R. V., & Kamper, D. G. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047588 · Cited by 271
Self-Aligning Exoskeleton Axes Through Decoupling of Joint Rotations and Translations
Stienen, A. H. A., Hekman, E. E. G., van der Helm, F. C. T., & van der Kooij, H. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2019147 · Cited by 249
Healthwear: medical technology becomes wearable
Pentland, A. (2004) · Computer · doi:10.1109/mc.2004.1297238 · Cited by 192
Portable Exoskeleton Glove With Soft Structure for Hand Assistance in Activities of Daily Living
Popov, D., Gaponov, I., & Ryu, J.-H. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2641932 · Cited by 191
Nycz, C. J., Bützer, T., Lambercy, O., Arata, J., Fischer, G. S., & Gassert, R. (2016) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2016.2528296 · Cited by 174
Jones, C. L., Wang, F., Morrison, R. M., Sarkar, N., & Kamper, D. G. (2012) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2012.2224359 · Cited by 155
Gloreha—Hand Robotic Rehabilitation: Design, Mechanical Model, and Experiments
Borboni, A., Mor, M., & Faglia, R. (2016) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.4033831 · Cited by 145
Exo-Glove PM: An Easily Customizable Modularized Pneumatic Assistive Glove
Yun, S.-S., Kang, B. B., & Cho, K. (2017) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2017.2678545 · Cited by 139
Self-citationLee, S. W., Landers, K. A., & Park, H. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2298362 · Cited by 128
In, H., Jeong, U., Lee, H., & Cho, K. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2606574 · Cited by 47
Self-citationDesign of a passive brake mechanism for tendon driven devices
Kang, S., In, H., & Cho, K. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0196-y · Cited by 19
Self-citation
Cited by
Soft actuators for real-world applications
Li, M., Pal, A., Aghakhani, A., Pena-Francesch, A., & Sitti, M. (2021) · Nature Reviews Materials · doi:10.1038/s41578-021-00389-7 · Cited by 880
Sun, Z., Zhu, M., Shan, X., & Lee, C. (2022) · Nature Communications · doi:10.1038/s41467-022-32745-8 · Cited by 532
A Soft Exoskeleton for Tremor Suppression Equipped with Flexible Semiactive Actuator
Zahedi, A., Zhang, B., Yi, A., & Zhang, D. (2021) · Soft Robotics · doi:10.1089/soro.2019.0194 · Cited by 57
Metadata
- Authors
- Kang, B. B., Choi, H., Lee, H., & Cho, K.-J.
- Venue
- Soft Robotics
- Publisher
- SAGE Publications
- Published
- 2019-04
- Volume
- 6
- Issue
- 2
- Pages
- 214-227
- ISSN
- 2169-5172 (ISSN-L)
- 2169-5180
- OpenAlex
- W2904422212
- Cited by
- 257
- References
- 18
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.