The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Origami-Based Vacuum Pneumatic Artificial Muscles with Large Contraction Ratios
Abstract
A novel linear actuator called origami-based vacuum pneumatic artificial muscle (OV-PAM) is proposed in this study that can produce large forces (>400 N) with a contraction ratio >90% of the active length of the actuator. Moreover, some of the designs presented in this article can lift large loads with large contraction ratios at extremely low vacuum pressure (≈10 kPa). This actuator consists of a sealed origami film chamber connecting a polygonal top and bottom plate with evenly spaced transversal reinforcements that prevent the chamber from contracting laterally at certain points of the actuator under vacuum pressure. As vacuum pressure is applied, both a tension force in the walls and a vertical force on the bottom plate of the actuator generate a large contractile force, and the force on the bottom plate can produce a consistent force throughout the entire motion. A quasistatic analytical model was developed that can accurately predict the behavior of the actuator and that can be used for actuator design. OV-PAMs are lightweight, have large contractile forces throughout their entire motion and large contraction ratios. It can also produce large forces at low pressures with large cross-sectional areas. Their versatility could make them well suited for a wide range of applications. They could take us closer to a future where robots can cooperate with humans to shape a better future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design, fabrication and control of soft robots
Rus, D., & Tolley, M. T. (2015) · Nature · doi:10.1038/nature14543 · Cited by 5,825
Soft robotics: a bioinspired evolution in robotics
Kim, S., Laschi, C., & Trimmer, B. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.03.002 · Cited by 2,092
Soft material for soft actuators
Miriyev, A., Stack, K., & Lipson, H. (2017) · Nature Communications · doi:10.1038/s41467-017-00685-3 · Cited by 861
Exo-Glove: A Wearable Robot for the Hand with a Soft Tendon Routing System
In, H., Kang, B. B., Sin, M., & Cho, K.-J. (2015) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2362863 · Cited by 473
Cited by
Xavier, M. S., Tawk, C. D., Zolfagharian, A., Pinskier, J., Howard, D., Young, T., Lai, J., Harrison, S. M., Yong, Y. K., Bodaghi, M., et al. (2022) · IEEE Access · doi:10.1109/access.2022.3179589 · Cited by 418
Park, J. H., Kim, K., Gong, Y. J., Yang, S. Y., Hwang, S. T., Jung, H. S., Moon, H., Koo, J. C., Rodrigue, H., & Choi, H. R. (2024) · Mechatronics · doi:10.1016/j.mechatronics.2023.103099 · Cited by 15
Self-citation
Metadata
- Authors
- Lee, J.-G., & Rodrigue, H.
- Venue
- Soft Robotics
- Publisher
- SAGE Publications
- Published
- 2019-02
- Volume
- 6
- Issue
- 1
- Pages
- 109-117
- ISSN
- 2169-5172 (ISSN-L)
- 2169-5180
- OpenAlex
- W2896729926
- Cited by
- 187
- References
- 4
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Origami-Based Vacuum Pneumatic Artificial Muscles with Large Contraction Ratios. https://app.cochat.ai/papers/10.1089/soro.2018.0063
- The paper
- Lee, J.-G., & Rodrigue, H. (2019). Origami-Based Vacuum Pneumatic Artificial Muscles with Large Contraction Ratios. Soft Robotics. https://doi.org/10.1089/soro.2018.0063
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.