Poly(ethylene glycol) Hydrogel System Supports Preadipocyte Viability, Adhesion, and Proliferation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The ultimate goal of this research is to develop an injectable cell-scaffold system capable of permitting adipogenesis to abrogate soft tissue deficiencies resulting from trauma, tumor resection, and congenital abnormalities. The present work compares the efficacy of photopolymerizable poly(ethylene glycol) and specific derivatives as a scaffold for preadipocyte (adipocyte precursor cell) viability, adhesion, and proliferation. Four variations of a poly(ethylene glycol) scaffold are prepared and examined. The first scaffold consists of poly(ethylene glycol) diacrylate, which is not susceptible to hydrolysis or enzymatic degradation. Preadipocyte death is observed over 1 week in this hydrogel configuration. Adhesion sites, specifically the laminin-binding peptide sequence YIGSR, were incorporated into the second scaffold to promote cellular adhesion as a prerequisite for preadipocyte proliferation. Preadipocytes remain viable in this scaffold system, but do not proliferate in this nondegradable hydrogel. The third scaffold system studied consists of poly(ethylene glycol) modified with the peptide sequence LGPA to permit polymer degradation by cell-secreted collagenase. No adhesion peptide is incorporated into this scaffold system. Cellular proliferation is initially observed, followed by cell death. The previous three scaffold configurations do not permit preadipocyte adhesion and proliferation. In contrast, the fourth system studied, poly(ethylene glycol) modified to incorporate both LGPA and YIGSR, permits preadipocyte adherence and proliferation subsequent to polymer degradation. Our results indicate that a scaffold system containing specific degradation sites and cell adhesion ligands permits cells to adhere and proliferate, thus providing a potential cell-scaffold system for adipogenesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photopolymerizable hydrogels for tissue engineering applications
Nguyen, K. T., & West, J. L. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00175-8 · Cited by 1,669
Self-citation
Cited by
Hydrogels as extracellular matrix mimics for 3D cell culture
Tibbitt, M. W., & Anseth, K. S. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22361 · Cited by 2,727
“In PEG scaffolds the incorporation of pendant RGD—the known binding domain of fibronectin—has been shown to increase viability and adhesion of encapsulated cells (Nuttelman et al., 2005; Park et al., 2005; Patel et al., 2005).”
BackgroundNuclear Lamin-A Scales with Tissue Stiffness and Enhances Matrix-Directed Differentiation
Swift, J., Ivanovska, I. L., Buxboim, A., Harada, T., Dingal, P. C. D. P., Pinter, J., Pajerowski, J. D., Spinler, K. R., Shin, J.-W., Tewari, M., et al. (2013) · Science · doi:10.1126/science.1240104 · Cited by 1,991
25th Anniversary Article: Engineering Hydrogels for Biofabrication
Malda, J., Visser, J., Melchels, F. P., Jüngst, T., Hennink, W. E., Dhert, W. J. A., Groll, J., & Hutmacher, D. W. (2013) · Advanced Materials · doi:10.1002/adma.201302042 · Cited by 1,901
Bioactive modification of poly (ethylene glycol) hydrogels for tissue engineering
Zhu, J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.044 · Cited by 1,457
Design properties of hydrogel tissue-engineering scaffolds
Zhu, J., & Marchant, R. E. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.27 · Cited by 1,430
Metadata
- Authors
- Patel, P. N., Gobin, A. S., West, J. L., & Patrick, C. W.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2005-09
- Volume
- 11
- Issue
- 9-10
- Pages
- 1498-1505
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2066036756
- Cited by
- 148
- References
- 1
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.