Diffusion Limits of an in Vitro Thick Prevascularized Tissue
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Although tissue engineering promises to replace or restore lost function to nearly every tissue in the body, successful applications are currently limited to tissue less than 2 mm in thickness. in vivo capillary networks deliver oxygen and nutrients to thicker (> 2 mm) tissues, suggesting that introduction of a preformed in vitro vascular network may be a useful strategy for engineered tissues. This article describes a system for generating capillary-like networks within a thick fibrin matrix. Human umbilical vein endothelial cells, growing on the surface of microcarrier beads, were embedded in fibrin gels a known distance (Delta = 1.8-4.5 mm) from a monolayer of human dermal fibroblasts. The distance of the growth medium, which contained vascular endothelial growth factor and basic fibroblast growth factor, from the beads, C, was varied from 2.7 to 7.2 mm. Capillaries with visible lumens sprouted in 2-3 days, reaching lengths that exceeded 500 microm within 6-8 days. On day 7, capillary network formation was largely independent of C; however, a strong inverse correlation with Delta was observed, with the maximum network formation at Delta = 1.8 mm. Surprisingly, the thickness of the gel was not a limiting factor for oxygen diffusion as these tissue constructs retained a relatively high oxygen tension of > 125 mmHg. We conclude that diffusion of oxygen in vitro is not limiting, allowing the development of tissue constructs on the order of centimeters in thickness. In addition, diffusion of fibroblast-derived soluble mediators is necessary for stable capillary formation, but is significantly impeded relative to that of nutrients present in the medium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Remission in models of type 1 diabetes by gene therapy using a single-chain insulin analogue
Lee, H. C., Kim, S.-J., Kim, K.-S., Shin, H.-C., & Yoon, J.-W. (2000) · Nature · doi:10.1038/35044106 · Cited by 434
RetractedSzer, J. (1999) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1999.tb127745.x · Cited by 3,353
In Vivo Imaging of Embryonic Vascular Development Using Transgenic Zebrafish
Lawson, N. D., & Weinstein, B. M. (2002) · Developmental Biology · doi:10.1006/dbio.2002.0711 · Cited by 2,151
Biodegradable Polymer Scaffolds for Tissue Engineering
Freed, L. E., Vunjak-Novakovic, G., Biron, R. J., Eagles, D. B., Lesnoy, D. C., Barlow, S. K., & Langer, R. (1994) · Nature Biotechnology · doi:10.1038/nbt0794-689 · Cited by 1,235
Signaling Vascular Morphogenesis and Maintenance
Hanahan, D. (1997) · Science · doi:10.1126/science.277.5322.48 · Cited by 1,190
Transforming growth factor-beta: Vasculogenesis, angiogenesis, and vessel wall integrity
Pepper, M. S. (1997) · Cytokine & Growth Factor Reviews · doi:10.1016/s1359-6101(96)00048-2 · Cited by 724
Controlled growth factor release from synthetic extracellular matrices
Lee, K. Y., Peters, M. C., Anderson, K. W., & Mooney, D. J. (2000) · Nature · doi:10.1038/35050141 · Cited by 505
Cardiac muscle tissue engineering: toward an in vitro model for electrophysiological studies
Bursac, N., Papadaki, M., Cohen, R. J., Schoen, F. J., Eisenberg, S. R., Carrier, R., Vunjak-Novakovic, G., & Freed, L. E. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.277.2.h433 · Cited by 366
Schechner, J. S., Nath, A. K., Zheng, L., Kluger, M. S., Hughes, C. C. W., Sierra-Honigmann, M. R., Lorber, M. I., Tellides, G., Kashgarian, M., Bothwell, A. L. M., et al. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.150242297 · Cited by 327
Self-citationBryant, S. J., & Anseth, K. S. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00225-8 · Cited by 310
Papadaki, M., Bursac, N., Langer, R., Merok, J., Vunjak-Novakovic, G., & Freed, L. E. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.280.1.h168 · Cited by 284
Preadipocyte Seeded PLGA Scaffolds for Adipose Tissue Engineering
Patrick, C. W., Chauvin, P. B., Hobley, J., & Reece, G. P. (1999) · Tissue Engineering · doi:10.1089/ten.1999.5.139 · Cited by 283
Kim, B.-S., Putnam, A. J., Kulik, T. J., & Mooney, D. J. (1998) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19980105)57:1<46::aid-bit6>3.0.co;2-v · Cited by 272
Martin, I., Vunjak-Novakovic, G., Yang, J., Langer, R., & Freed, L. E. (1999) · Experimental Cell Research · doi:10.1006/excr.1999.4708 · Cited by 261
Engineering vascular networks in porous polymer matrices
Peters, M. C., Polverini, P. J., & Mooney, D. J. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10134 · Cited by 238
Ghajar, C. M., Blevins, K. S., Hughes, C. C. W., George, S. C., & Putnam, A. J. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2875 · Cited by 224
Self-citationElçin, Y. M., Dixit, V., & Gitnick, G. (2001) · Artificial Organs · doi:10.1046/j.1525-1594.2001.025007558.x · Cited by 224
Cleland, J. L., Duenas, E. T., Park, A., Daugherty, A., Kahn, J., Kowalski, J., & Cuthbertson, A. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00258-9 · Cited by 222
Construction of a bioengineered cardiac graft
Li, R.-K., Yau, T. M., Weisel, R. D., Mickle, D. A. G., Sakai, T., Choi, A., & Jia, Z.-Q. (2000) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(00)70193-0 · Cited by 208
King, T. W., & Patrick, C. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20000905)51:3<383::aid-jbm12>3.0.co;2-d · Cited by 187
Systems for therapeutic angiogenesis in tissue engineering
Soker, S., Machado, M., & Atala, A. (2000) · World Journal of Urology · doi:10.1007/pl00007070 · Cited by 185
Controlled release of vascular endothelial growth factor by use of collagen hydrogels
Tabata, Y., Miyao, M., Ozeki, M., & Ikada, Y. (2000) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856200744101 · Cited by 150
Zandonella, C. (2003) · Nature · doi:10.1038/421884a · Cited by 135
Balconi, G., Spagnuolo, R., & Dejana, E. (2000) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.20.6.1443 · Cited by 102
In vivo characterization of a porous hydrogel material for use as a tissue bulking agent
Loebsack, A. B., Greene, K. G., Wyatt, S. B., Culberson, C., Austin, C. E., Beiler, R., Roland, W. D., Eiselt, P., Rowley, J. A., Burg, K. J. L., et al. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20011215)57:4<575::aid-jbm1204>3.0.co;2-9 · Cited by 101
In vitro model of a vascular stroma for the engineering of vascularized tissues
Frerich, B., Lindemann, N., Kurtz‐Hoffmann, J., & Oertel, K. (2001) · International Journal of Oral and Maxillofacial Surgery · doi:10.1054/ijom.2001.0130 · Cited by 94
Hopkins, S. P., Bulgrin, J. P., Sims, R. L., Bowman, B., Donovan, D. L., & Schmidt, S. P. (1998) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(98)70269-1 · Cited by 61
Fontaine, M. J., Schloo, B. L., Jenkins, R. L., Uyama, S., Hansen, L. K., & Vacanti, J. P. (1995) · Journal of Pediatric Surgery · doi:10.1016/0022-3468(95)90610-x · Cited by 32
Ajioka, I., Nishio, R., Ikekita, M., Akaike, T., Sasaki, M., Enami, J., & Watanabe, Y. (2001) · Tissue Engineering · doi:10.1089/10763270152044198 · Cited by 27
Hyaluronate‐alginate gel as a novel biomaterial: Mechanical properties and formation mechanism
Oerther, S., Gall, H. L., Payan, E., Lapicque, F., Presle, N., Hubert, P., Dexheimer, J., Netter, P., & Lapicque, F. (1999) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19990420)63:2<197::aid-bit8>3.0.co;2-2 · Cited by 2
Cited by
3D bioprinting of vascularized, heterogeneous cell-laden tissue constructs
Kolesky, D. B., Truby, R. L., Gladman, A. S., Busbee, T. A., Homan, K. A., & Lewis, J. A. (2014) · Advanced Materials · doi:10.1002/adma.201305506 · Cited by 2,102
Direct 3D bioprinting of perfusable vascular constructs using a blend bioink
Jia, W., Gungor-Ozkerim, P. S., Zhang, Y. S., Yue, K., Zhu, K., Liu, W., Pi, Q., Byambaa, B., Dokmeci, M. R., Shin, S. R., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.07.038 · Cited by 922
Vascularization Strategies for Tissue Engineering
Lovett, M., Lee, K., Edwards, A., & Kaplan, D. L. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0085 · Cited by 923
The use of whole organ decellularization for the generation of a vascularized liver organoid
Baptista, P. M., Siddiqui, M. M., Lozier, G., Rodriguez, S. R., Atala, A., & Soker, S. (2011) · Hepatology · doi:10.1002/hep.24067 · Cited by 681
Advances in the formation, use and understanding of multi-cellular spheroids
Achilli, T.-M., Meyer, J., & Morgan, J. R. (2012) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.2012.707181 · Cited by 572
Metadata
- Authors
- Griffith, C. K., Miller, C., Sainson, R. C. A., Calvert, J. W., Jeon, N. L., Hughes, C. C. W., & George, S. C.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2005-01
- Volume
- 11
- Issue
- 1-2
- Pages
- 257-266
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2030426885
- Cited by
- 346
- References
- 30
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.