Transplantation of Allogeneic Chondrocytes Cultured in Fibroin Sponge and Stirring Chamber to Promote Cartilage Regeneration
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Cartilage regeneration using a fibroin sponge and a stirring chamber was investigated to improve the potential of articular cartilage tissue engineering. Chondrocytes seeded on the fibroin-sponge scaffolds were cultured in the stirring chamber (a bioreactor facilitating mechanical stimulation) for up to 3 weeks. Changes in DNA content, glycosaminoglycan (GAG) amount, integrin subunits alpha5 and beta1 fluorescence intensity, and morphologic appearance, were studied to evaluate tissue maturity. Seeded scaffolds subjected to the stirring chamber demonstrated significant increases in both DNA content (38.9%) and GAG content (54.3%) at day 21 compared to the control group. In addition, the stirring chamber system facilitated a maturation of cartilage tissue showed by histologic examination, after a staining of proteoglycan and type II collagen. Clinical feasibility of the fibroin and stirring chamber system was evaluated using rabbit models with cartilage defect. Large defects on rabbit knee joints were repaired with regenerated cartilage, which resembles hyaline cartilage at 12 weeks after operation. These studies demonstrated the potential of such mechanically stimulated scaffold/cell constructs to support chondrogenesis in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Altman, G. H., Diaz, F., Jakuba, C., Calabro, T., Horan, R. L., Chen, J., Lu, H., Richmond, J., & Kaplan, D. L. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00353-8 · Cited by 3,458
Cited by
Silk fibroin biomaterials for tissue regenerations
Kundu, B., Rajkhowa, R., Kundu, S. C., & Wang, X. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.043 · Cited by 1,391
Elastomeric biomaterials for tissue engineering
Chen, Q., Liang, S., & Thouas, G. A. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.05.003 · Cited by 564
Silk fibroin as a functional biomaterial for tissue engineering
Sun, W., Gregory, D. A., Tomeh, M. A., & Zhao, X. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22031499 · Cited by 552
Silk protein-based hydrogels: Promising advanced materials for biomedical applications
Kapoor, S., & Kundu, S. C. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.11.034 · Cited by 500
Silk Fibroin in Tissue Engineering
Kasoju, N., & Bora, U. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200097 · Cited by 383
Metadata
- Authors
- Shangkai, C., Naohide, T., Koji, Y., Yasuji, H., Masaaki, N., Tomohiro, T., & Yasushi, T.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2007-03
- Volume
- 13
- Issue
- 3
- Pages
- 483-492
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2002345819
- Cited by
- 67
- References
- 1
- FWCI
- 4.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.