Autologous Tenocyte Therapy Using Porcine-Derived Bioscaffolds for Massive Rotator Cuff Defect in Rabbits
The DOI matches its Crossref record.
Abstract
Large and retracted rotator cuff tendon tears fail to repair or retear after surgical intervention. This study attempted to develop novel tissue-engineering approaches using tenocyte-seeded bioscaffolds for tendon reconstruction of massive rotator cuff tendon defect in rabbits. Porcine small intestine submucosa (Restore) and type I/III collagen bioscaffold (ACI-Maix) were chosen as bioscaffold carriers for autologous tenocytes. Biological characterization of autologous tenocytes was conducted before the implantation. The tenocyte-seeded bioscaffolds were implanted as interposition grafts to reconstruct massive rotator cuff tendon defects in rabbits. In situ reimplantation of the autologous rotator cuff tendon, excised during defect creation, served as a positive control. Histological outcomes were analyzed and semi-quantitatively graded at 4 and 8 weeks after surgery. At 4 weeks, both tenocyte-seeded bioscaffolds displayed inflammatory reaction similar to bioscaffold-only cuff reconstruction, and the histological grading were inferior to control repair. However, at 8 weeks, inflammatory reaction of both tenocyte-seeded bioscaffolds were dramatically less than with bioscaffold alone. In addition, bioscaffolds seeded with tenocytes generated a histological appearance similar to that of the positive control. The implantation of autologous tenocytes on collagen-based bioscaffolds results in better rotator cuff tendon healing and remodeling than with the implantation of bioscaffold alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Docheva, D., Müller, S. A., Majewski, M., & Evans, C. H. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.11.015 · Cited by 693
Functional Attachment of Soft Tissues to Bone: Development, Healing, and Tissue Engineering
Lu, H. H., & Thomopoulos, S. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124656 · Cited by 447
Hernigou, P., Flouzat Lachaniette, C. H., Delambre, J., Zilber, S., Duffiet, P., Chevallier, N., & Rouard, H. (2014) · International Orthopaedics · doi:10.1007/s00264-014-2391-1 · Cited by 436
Tendon augmentation grafts: a systematic review
Longo, U. G., Lamberti, A., Maffulli, N., & Denaro, V. (2010) · British Medical Bulletin · doi:10.1093/bmb/ldp051 · Cited by 280
Jo, C. H., Kim, J. E., Yoon, K. S., & Shin, S. (2012) · The American Journal of Sports Medicine · doi:10.1177/0363546512437525 · Cited by 248
“This increase of type III collagen, especially relative to type I collagen, could inhibit the growth of collagen fibrils, lead to adhesion and contracture formation,(2,7,65) and may result in the tendon being less resistant to stress and thus at increased risk of rupture.(9,32,45) Some authors have reported that large…”
BackgroundTendon‐derived stem cells (TDSCs) promote tendon repair in a rat patellar tendon window defect model
Ni, M., Lui, P. P. Y., Rui, Y. F., Lee, Y. W., Lee, Y. W., Tan, Q., Wong, Y. M., Kong, S. K., Lau, P. M., Li, G., et al. (2012) · Journal of Orthopaedic Research · doi:10.1002/jor.21559 · Cited by 227
Extracellular matrix scaffold devices for rotator cuff repair
Derwin, K. A., Badylak, S. F., Steinmann, S. P., & Iannotti, J. P. (2010) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2009.10.020 · Cited by 204
Zhang, C., Yuan, H., Liu, H., Chen, X., Lu, P., Zhu, T., Yang, L., Yin, Z., Heng, B. C., Zhang, Y., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.051 · Cited by 197
Chen, X., Song, X.-H., Yin, Z., Zou, X.-H., Wang, L.-L., Hu, H., Cao, T., Zheng, M., & Ouyang, H. W. (2009) · Stem Cells · doi:10.1002/stem.61 · Cited by 179
Self-citationShen, W., Chen, X., Chen, J., Yin, Z., Heng, B. C., Chen, W., & Ouyang, H.-W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.040 · Cited by 160
Self-citationYin, Z., Chen, X., Zhu, T., Hu, J.-J., Song, H.-X., Shen, W.-L., Jiang, L.-Y., Heng, B. C., Ji, J.-F., & Ouyang, H.-W. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.07.022 · Cited by 148
Decellularized xenografts in regenerative medicine: From processing to clinical application
Capella‐Monsonís, H., & Zeugolis, D. I. (2021) · Xenotransplantation · doi:10.1111/xen.12683 · Cited by 57
Zhang, J., Nie, D., Williamson, K., Rocha, J. L., Hogan, M. V., & Wang, J. H.-C. (2019) · Journal of Tissue Engineering · doi:10.1177/2041731418820034 · Cited by 25
Metadata
- Authors
- Chen, J. M., Willers, C., Xu, J., Wang, A., & Zheng, M.-H.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2007-07
- Volume
- 13
- Issue
- 7
- Pages
- 1479-1491
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2543278837
- Cited by
- 146
- References
- 0
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.