The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Biomimetic Approach to Cardiac Tissue Engineering: Oxygen Carriers and Channeled Scaffolds
Abstract
We report that the functional assembly of engineered cardiac muscle can be enhanced by oxygen supply provided by mechanisms resembling those in normal vascularized tissues. To mimic the capillary network, cardiomyocytes and fibroblasts isolated from the neonatal rat hearts were cultured on a highly porous elastomer with a parallel array of channels that were perfused with culture medium. To mimic oxygen supply by hemoglobin, culture medium was supplemented with a perfluorocarbon (PFC) emulsion; constructs perfused with unsupplemented culture medium served as controls. In PFC-supplemented medium, the decrease in the partial pressure of oxygen in the aqueous phase was only 50% of that in control medium (28 mmHg vs. 45 mmHg between the construct inlet and outlet at a flow rate of 0.1 mL/min). Consistently, constructs cultivated in the presence of PFC contained higher amounts of DNA and cardiac markers (troponin I, connexin-43) and had significantly better contractile properties as compared to control constructs. In both groups, electron microscopy revealed open channels and the presence of cells at the channel surfaces as well as within constructs. Improved properties of cardiac constructs could be correlated with the enhanced supply of oxygen to the cells, by a combined use of channeled scaffolds and PFC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorometric assay of DNA in cartilage explants using Hoechst 33258
Kim, Y.-J., Sah, R. L. Y., Doong, J.-Y. H., & Grodzinsky, A. J. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90532-5 · Cited by 1,357
A tough biodegradable elastomer
Wang, Y., Ameer, G. A., Sheppard, B. J., & Langer, R. (2002) · Nature Biotechnology · doi:10.1038/nbt0602-602 · Cited by 1,314
Self-citationPostnatal isl1+ cardioblasts enter fully differentiated cardiomyocyte lineages
Laugwitz, K.-L., Moretti, A., Lam, J., Gruber, P., Chen, Y., Woodard, S., Lin, L.-Z., Cai, C.-L., Lu, M. M., Reth, M., et al. (2005) · Nature · doi:10.1038/nature03215 · Cited by 1,304
Tissue Engineering of a Differentiated Cardiac Muscle Construct
Zimmermann, W.-H., Schneiderbanger, K., Schubert, P., Didié, M., Münzel, F., Heubach, J. F., Kostin, S., Neuhuber, W. L., & Eschenhagen, T. (2002) · Circulation Research · doi:10.1161/hh0202.103644 · Cited by 917
Radisic, M., Park, H., Shing, H., Consi, T., Schoen, F. J., Langer, R., Freed, L. E., & Vunjak-Novakovic, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407817101 · Cited by 910
Self-citationEschenhagen, T., Fink, C., Remmers, U., Scholz, H., Wattchow, J., Weil, J., Zimmermann, W., Dohmen, H. H., Schäfer, H., Bishopric, N., et al. (1997) · The FASEB Journal · doi:10.1096/fasebj.11.8.9240969 · Cited by 636
Carrier, R. L., Papadaki, M., Rupnick, M., Schoen, F. J., Bursac, N., Langer, R., Freed, L. E., & Vunjak-Novakovic, G. (1999) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19990905)64:5<580::aid-bit8>3.0.co;2-x · Cited by 540
Self-citationCoupling of Cardiac Electrical Activity Over Extended Distances by Fibroblasts of Cardiac Origin
Gaudesius, G., Miragoli, M., Thomas, S. P., & Rohr, S. (2003) · Circulation Research · doi:10.1161/01.res.0000089258.40661.0c · Cited by 505
Sikavitsas, V. I., Bancroft, G. N., Holtorf, H. L., Jansen, J. A., & Mikos, A. G. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2434367100 · Cited by 472
Oxygen gradients correlate with cell density and cell viability in engineered cardiac tissue
Radisic, M., Malda, J., Epping, E., Geng, W., Langer, R., & Vunjak‐Novakovic, G. (2006) · Biotechnology and Bioengineering · doi:10.1002/bit.20722 · Cited by 399
Self-citation
Cited by
Vascularization Strategies for Tissue Engineering
Lovett, M., Lee, K., Edwards, A., & Kaplan, D. L. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0085 · Cited by 923
Accordion-like honeycombs for tissue engineering of cardiac anisotropy
Engelmayr, G. C., Cheng, M., Bettinger, C. J., Borenstein, J. T., Langer, R., & Freed, L. E. (2008) · Nature Materials · doi:10.1038/nmat2316 · Cited by 848
Self-citationTissue engineering by self-assembly and bio-printing of living cells
Jakab, K., Norotte, C., Marga, F., Murphy, K., Vunjak-Novakovic, G., & Forgacs, G. (2010) · Biofabrication · doi:10.1088/1758-5082/2/2/022001 · Cited by 593
Self-citationScaffold: A Novel Carrier for Cell and Drug Delivery
Garg, T., Singh, O., Arora, S., & Murthy, R. S. R. (2012) · Critical Reviews in Therapeutic Drug Carrier Systems · doi:10.1615/critrevtherdrugcarriersyst.v29.i1.10 · Cited by 549
Challenges in Cardiac Tissue Engineering
Vunjak-Novakovic, G., Tandon, N., Godier, A., Maidhof, R., Marsano, A., Martens, T. P., & Radisic, M. (2010) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0352 · Cited by 511
Self-citation
Metadata
- Authors
- Radisic, M., Park, H., Chen, F., Salazar-Lazzaro, J. E., Wang, Y., Dennis, R., Langer, R., Freed, L. E., & Vunjak-Novakovic, G.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2006-08
- Volume
- 12
- Issue
- 8
- Pages
- 2077-2091
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2011085226
- Cited by
- 325
- References
- 38
- FWCI
- 19.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biomimetic Approach to Cardiac Tissue Engineering: Oxygen Carriers and Channeled Scaffolds. https://app.cochat.ai/papers/10.1089/ten.2006.12.2077
- The paper
- Radisic, M., Park, H., Chen, F., Salazar-Lazzaro, J. E., Wang, Y., Dennis, R., Langer, R., Freed, L. E., & Vunjak-Novakovic, G. (2006). Biomimetic Approach to Cardiac Tissue Engineering: Oxygen Carriers and Channeled Scaffolds. Tissue Engineering. https://doi.org/10.1089/ten.2006.12.2077
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.