CoChat

RETRACTED: Replacement of a Tracheal Stenosis with a Tissue-Engineered Human Trachea Using Autologous Stem Cells: A Case Report

Berg, Malin, Ejnell, Hasse, Kovács, Anikó, Nayakawde, Nikhil, Patil, Pradeep B., Joshi, Meghnad, Aziz, Luaay, Rådberg, Göran, Hajizadeh, Shahin, Olausson, Michael, Sumitran-Holgersson, Suchitra · 2014 · Tissue Engineering Part A
Cited by 58

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Cell-based therapies involving tissue engineering represent interesting and potentially important strategies for the treatment of patients with various disorders. In this study, using a detergent-enzymatic method, we prepared an intact three-dimensional scaffold of an extracellular matrix derived from a human cadaver donor trachea, which we repopulated with autologous stem cells and implanted into a 76-year-old patient with tracheal stenosis including the lower part of the larynx. Although the graft provided the patient with an open airway, a week after the surgery, the mucous membrane of the graft was covered by a 1-2 mm thick fungal infection, which was treated with local and systemic antifungal therapy. The airway lumen was postoperatively controlled by fiber endoscopy and found stable and sufficient. However, after 23 days, the patient died due to cardiac arrest but with a patent, open, and stable tracheal transplant and intact anastomoses. Histopathological results of the transplanted tracheal graft during autopsy showed a squamous but not ciliated epithelium, neovascularization, bundles of α-sma-positive muscle cells, serous glands, and nerve fibers with S-100-positive nerve cells in the submucosa and intact chondrocytes in the cartilage. Our findings suggest that although autologous stem cells-engineered tracheal matrices may represent a tool for clinical tracheal replacement, further preclinical studies are required for generating functional airway grafts and long-term effects of such grafts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.tea.2012.0514This paper is marked retracted.

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Berg, M., Ejnell, H., Kovács, A., Nayakawde, N., Patil, P. B., Joshi, M., Aziz, L., Rådberg, G., Hajizadeh, S., Olausson, M., & Sumitran-Holgersson, S.
Venue
Tissue Engineering Part A
Published
2014-01
Volume
20
Issue
1-2
Pages
389-397
ISSN
  • 1937-3341 (ISSN-L)
  • 1937-335X
OpenAlex
W1549174553
Cited by
58
References
1
FWCI
9.88
Type
journal article
Language
en
Status
Retracted
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.