Fabrication and Evaluation of PLLA Multichannel Conduits with Nanofibrous Microstructure for the Differentiation of NSCs In Vitro
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Nerve conduits (NCs) with multiple longitudinally aligned channels, being mimicking the natural nerves anatomical structure, have been attracted more and more attentions. However, some specific structural parameters of a conduit that would be beneficial for further improvement of neural tissue regeneration were not comprehensively considered. Using a systematized device and combining low-pressure injection molding and thermal-induced phase separation, we fabricated 33-channel NCs (outer diameter 3.5 mm, channel diameter 200 μm) with different well-defined microscopic features, including NCs with a nano-fibrous microstructure (NNC), NCs with microspherical pores and nano-fibrous pore walls (MNC), and NCs with a ladder-like microstructure (LNC). The porosities of these NCs were ∼90% and were independent of the fine microstructures, whereas the pore size distributions were clearly distinct. The adsorption of bovine serum albumin for the NNC was a result of having the highest specific surface area, which was 3.5 times that of the LNC. But the mechanical strength of NNC was lower than that of two groups because of a relative high crystallinity and brittle characteristics. In vitro nerve stem cells (NSCs) incubation revealed that 14 days after seeding the NSCs, 31.32% cells were Map2 positive in the NNC group, as opposed to 15.76% in the LNC group and 23.29% in the MNC group. Addition of NGF into the culture medium, being distinctive specific surface area and a high adsorption of proteon for NNC, 81.11% of neurons derived from the differentiation of the seeded NSCs was obtained. As a result of imitating the physical structure of the basement membrane of the neural matrix, the nanofibrous structure of the NCs has facilitated the differentiation of NSCs into neurons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wei, G., & Ma, P. X. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.12.005 · Cited by 1,271
Yim, E. K. F., Pang, S. W., & Leong, K. W. (2007) · Experimental Cell Research · doi:10.1016/j.yexcr.2007.02.031 · Cited by 735
Polypyrrole-coated electrospun PLGA nanofibers for neural tissue applications
Lee, J. Y., Bashur, C. A., Goldstein, A. S., & Schmidt, C. E. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.042 · Cited by 735
Widmer, M. S., Gupta, P. K., Lu, L., Meszlenyi, R. K., Evans, G. R. D., Brandt, K., Savel, T., Gurlek, A., Patrick, C. W., & Mikos, A. G. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00099-4 · Cited by 372
Guidance of stem cell fate on 2D patterned surfaces
Kolind, K., Leong, K. W., Besenbacher, F., & Foss, M. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.070 · Cited by 163
Development and analysis of multi-layer scaffolds for tissue engineering
Papenburg, B. J., Liu, J., Higuera, G. A., Barradas, A. M. C., de Boer, J., van Blitterswijk, C. A., Wessling, M., & Stamatialis, D. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.07.057 · Cited by 125
Polyimide micro-channel arrays for peripheral nerve regenerative implants
Lacour, S. P., Atta, R., FitzGerald, J. J., Blamire, M., Tarte, E., & Fawcett, J. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.05.031 · Cited by 56
Cited by
Vijayavenkataraman, S. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.02.003 · Cited by 556
Current and Novel Polymeric Biomaterials for Neural Tissue Engineering
Boni, R., Ali, A., Shavandi, A., & Clarkson, A. N. (2018) · Journal of Biomedical Science · doi:10.1186/s12929-018-0491-8 · Cited by 439
3D Printed Personalized Nerve Guide Conduits for Precision Repair of Peripheral Nerve Defects
Liu, K., Yan, L., Li, R., Song, Z., Ding, J., Liu, B., & Chen, X. (2022) · Advanced Science · doi:10.1002/advs.202103875 · Cited by 183
Ma, C., Zhang, P., & Shen, Y. (2019) · Journal of Neurorestoratology · doi:10.26599/jnr.2019.9040024 · Cited by 19
“The pore ratio and modification of its chemical composition can be precisely regulated, providing mechanical support for cell transplantation, axonal regeneration and reconstruction of synapses, as well as chemical orientation information [21].”
Background
Metadata
- Authors
- Zeng, C.-G., Xiong, Y., Xie, G., Dong, P., & Quan, D.
- Venue
- Tissue Engineering Part A
- Publisher
- SAGE Publications
- Published
- 2014-03
- Volume
- 20
- Issue
- 5-6
- Pages
- 1038-1048
- ISSN
- 1937-3341 (ISSN-L)
- 1937-335X
- OpenAlex
- W1983090422
- Cited by
- 50
- References
- 7
- FWCI
- 0.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fabrication and Evaluation of PLLA Multichannel Conduits with Nanofibrous Microstructure for the Differentiation of NSCs In Vitro. https://app.cochat.ai/papers/10.1089/ten.tea.2013.0277
- The paper
- Zeng, C.-G., Xiong, Y., Xie, G., Dong, P., & Quan, D. (2014). Fabrication and Evaluation of PLLA Multichannel Conduits with Nanofibrous Microstructure for the Differentiation of NSCs In Vitro. Tissue Engineering Part A. https://doi.org/10.1089/ten.tea.2013.0277
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.