Implantation of Completely Biological Engineered Grafts Following Decellularization into the Sheep Femoral Artery
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The performance of completely biological, decellularized engineered allografts in a sheep model was evaluated to establish clinical potential of these unique arterial allografts. The 4-mm-diameter, 2-3-cm-long grafts were fabricated from fibrin gel remodeled into an aligned tissue tube in vitro by ovine dermal fibroblasts. Decellularization and subsequent storage had little effect on graft properties, with burst pressure exceeding 4000 mmHg and the same compliance as the ovine femoral artery. Grafts were implanted interpositionally in the femoral artery of six sheep (n=9), with contralateral sham controls (n=3). At 8 weeks (n=5) and 24 weeks (n=4), all grafts were patent and showed no evidence of dilatation or mineralization. Mid-graft lumen diameter was unchanged. Extensive recellularization occurred, with most cells expressing αSMA. Endothelialization was complete by 24 weeks with elastin deposition evident. These completely biological grafts possessed circumferential alignment/mechanical anisotropy characteristic of native arteries and were cultured only 5 weeks prior to decellularization and storage as "off-the-shelf" grafts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perfusion-decellularized matrix: using nature's platform to engineer a bioartificial heart
Ott, H. C., Matthiesen, T. S., Goh, S.-K., Black, L. D., Kren, S. M., Netoff, T. I., & Taylor, D. A. (2008) · Nature Medicine · doi:10.1038/nm1684 · Cited by 2,650 · cited 1×
“In this study, sequential SDS and Triton X-100 detergent treatments were used for decellularization.(27) This engineered tissue required 6 h for extensive removal of cellular components and did not elicit an immune response based on a lymphocyte proliferation assay.”
Decellularization of tissues and organs
Gilbert, T. W., Sellaro, T. L., & Badylak, S. F. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.02.014 · Cited by 2,222
Role of endothelial-mesenchymal transition (EndoMT) in the pathogenesis of fibrotic disorders
Piera-Velazquez, S., Li, Z., & Jimenez, S. A. (2011) · The American Journal of Pathology · doi:10.1016/j.ajpath.2011.06.001 · Cited by 580
Roh, J. D., Sawh-Martinez, R., Brennan, M. P., Jay, S. M., Devine, L., Rao, D. A., Yi, T., Mirensky, T. L., Nalbandian, A., Udelsman, B., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0911465107 · Cited by 559
Novel Utilization of Serum in Tissue Decellularization
Gui, L., Chan, S. A., Breuer, C. K., & Niklason, L. E. (2010) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2009.0120 · Cited by 109
Cited by
Extracellular matrix-based materials for regenerative medicine
Hussey, G. S., Dziki, J. L., & Badylak, S. F. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0023-x · Cited by 844
The Tissue-Engineered Vascular Graft—Past, Present, and Future
Pashneh-Tala, S., MacNeil, S., & Claeyssens, F. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0100 · Cited by 798
Role of animal models in biomedical research: a review
Mukherjee, P., Roy, S., Ghosh, D., & Nandi, S. K. (2022) · Laboratory Animal Research · doi:10.1186/s42826-022-00128-1 · Cited by 502
Decellularized matrices in regenerative medicine
Taylor, D. A., Sampaio, L. C., Ferdous, Z., Gobin, A. S., & Taite, L. J. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.04.044 · Cited by 337
Next-generation tissue-engineered heart valves with repair, remodelling and regeneration capacity
Fioretta, E. S., Motta, S. E., Lintas, V., Loerakker, S., Parker, K. K., Baaijens, F. P. T., Falk, V., Hoerstrup, S. P., & Emmert, M. Y. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0422-8 · Cited by 262
Metadata
- Authors
- Syedain, Z. H., Meier, L. A., Lahti, M. T., Johnson, S. L., & Tranquillo, R. T.
- Venue
- Tissue Engineering Part A
- Publisher
- SAGE Publications
- Published
- 2014-06
- Volume
- 20
- Issue
- 11-12
- Pages
- 1726-1734
- ISSN
- 1937-3341 (ISSN-L)
- 1937-335X
- OpenAlex
- W2090028890
- Cited by
- 147
- References
- 5
- FWCI
- 11.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.