CoChat

Three-Dimensional Printing and Injectable Conductive Hydrogels for Tissue Engineering Application

Jiang, Le, Wang, Yingjin, Liu, Zhongqun, Ma, Chunyang, Yan, Hao, Xu, Nan, Gang, Fangli, Wang, Xiumei, Zhao, Lingyun, Sun, Xiaodan · 2019 · Tissue Engineering Part B: Reviews
Cited by 92

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

The goal of tissue engineering scaffolds is to simulate the physiological microenvironment, in which the electrical microenvironment is an important part. Hydrogel is an ideal material for tissue engineering scaffolds because of its soft, porous, water-bearing, and other extracellular matrix-like properties. However, the hydrogel matrix is usually not conductive and can hinder the communication of electrical signals between cells, which promotes researchers' attention to conductive hydrogels. Conductive hydrogels can promote the communication of electrical signals between cells and simulate the physiological microenvironment of electroactive tissues. Hydrogel formation is an important step for the application of hydrogels in tissue engineering. In situ forming of injectable hydrogels and customized forming of three-dimensional (3D) printing hydrogels represent two most potential advanced forming processes, respectively. In this review, we discuss (i) the classification, properties, and advantages of conductive hydrogels, (ii) the latest development of conductive hydrogels applied in myocardial, nerve, and bone tissue engineering, (iii) advanced forming processes, including injectable conductive hydrogels in situ and customized 3D printed conductive hydrogels, (iv) the challenges and opportunities of conductive hydrogels for tissue engineering. Impact Statement Biomimetic construction of electro-microenvironment is a challenge of tissue engineering. The development of conductive hydrogels provides possibility for the construction of biomimetic electro-microenvironment. However, the importance of conductive hydrogels in tissue engineering has not received enough attention so far. Herein, various conductive hydrogels and their tissue engineering applications are systematically reviewed. Two potential methods of conductive hydrogel forming, in situ forming of injectable conductive hydrogels and customized forming of three-dimensional printing conductive hydrogels, are introduced. The current challenges and future development directions of conductive hydrogels are comprehensively overviewed. This review provides a guideline for tissue engineering applications of conductive hydrogels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.teb.2019.0100

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 92

Metadata

Authors
Jiang, L., Wang, Y., Liu, Z., Ma, C., Yan, H., Xu, N., Gang, F., Wang, X., Zhao, L., & Sun, X.
Venue
Tissue Engineering Part B: Reviews
Published
2019-10-01
Volume
25
Issue
5
Pages
398-411
ISSN
  • 1937-3368 (ISSN-L)
  • 1937-3376
OpenAlex
W2945911500
Cited by
92
References
8
FWCI
3.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.