CoChat

A Novel Miniaturized Multimodal Bioreactor for Continuous In Situ Assessment of Bioartificial Cardiac Tissue During Stimulation and Maturation

Open access
Kensah, George, Gruh, Ina, Viering, Jörg, Schumann, Henning, Dahlmann, Julia, Meyer, Heiko, Skvorc, David, Bär, Antonia, Akhyari, Payam, Heisterkamp, Alexander, Haverich, Axel, Martin, Ulrich · 2011 · Tissue Engineering Part C: Methods
Cited by 111

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Stem cell-based cardiac tissue engineering is a promising approach for regenerative therapy of the injured heart. At present, the small number of stem cell-derived cardiomyocytes that can be obtained using current culture and enrichment techniques represents one of the key limitations for the development of functional bioartificial cardiac tissue (BCT). We have addressed this problem by construction of a novel bioreactor with functional features of larger systems that enables the generation and in situ monitoring of miniaturized BCTs. BCTs were generated from rat cardiomyocytes to demonstrate advantages and usefulness of the bioreactor. Tissues showed spontaneous, synchronized contractions with cell orientation along the axis of strain. Cyclic stretch induced cardiomyocyte hypertrophy, demonstrated by a shift of myosin heavy chain expression from the alpha to beta isoform, together with elevated levels of atrial natriuretic factor. Stretch led to a moderate increase in systolic force (1.42 ± 0.09 mN vs. 0.96 ± 0.09 mN in controls), with significantly higher forces observed after β-adrenergic stimulation with noradrenalin (2.54 ± 0.11 mN). Combined mechanical and β-adrenergic stimulation had no synergistic effect. This study demonstrates for the first time that mechanical stimulation and direct real-time contraction force measurement can be combined into a single multimodal bioreactor system, including electrical stimulation of excitable tissue, perfusion of the culture chamber, and the possibility of (fluorescence) microscopic assessment during continuous cultivation. Thus, this bioreactor represents a valuable tool for monitoring tissue development and, ultimately, the optimization of stem cell-based tissue replacement strategies in regenerative medicine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.tec.2010.0405

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Kensah, G., Gruh, I., Viering, J., Schumann, H., Dahlmann, J., Meyer, H., Skvorc, D., Bär, A., Akhyari, P., Heisterkamp, A., Haverich, A., & Martin, U.
Venue
Tissue Engineering Part C: Methods
Published
2011-04
Volume
17
Issue
4
Pages
463-473
ISSN
  • 1937-3384 (ISSN-L)
  • 1937-3392
OpenAlex
W1971630553
Cited by
111
References
6
FWCI
6.83
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.