Multiscale Biomimetic Topography for the Alignment of Neonatal and Embryonic Stem Cell-Derived Heart Cells
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Nano- and microscale topographical cues play critical roles in the induction and maintenance of various cellular functions, including morphology, adhesion, gene regulation, and communication. Recent studies indicate that structure and function at the heart tissue level is exquisitely sensitive to mechanical cues at the nano-scale as well as at the microscale level. Although fabrication methods exist for generating topographical features for cell culture, current techniques, especially those with nanoscale resolution, are typically complex, prohibitively expensive, and not accessible to most biology laboratories. Here, we present a tunable culture platform comprised of biomimetic wrinkles that simulate the heart's complex anisotropic and multiscale architecture for facile and robust cardiac cell alignment. We demonstrate the cellular and subcellular alignment of both neonatal mouse cardiomyocytes as well as those derived from human embryonic stem cells. By mimicking the fibrillar network of the extracellular matrix, this system enables monitoring of protein localization in real time and therefore the high-resolution study of phenotypic and physiologic responses to in-vivo like topographical cues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human cardiovascular progenitor cells develop from a KDR+ embryonic-stem-cell-derived population
Yang, L., Soonpaa, M. H., Adler, E. D., Roepke, T. K., Kattman, S. J., Kennedy, M., Henckaerts, E., Bonham, K., Abbott, G. W., Linden, R. M., et al. (2008) · Nature · doi:10.1038/nature06894 · Cited by 1,389 · cited 3×
“The hESC (WiCells) HES2 line (NIH code: ES02) was cultured under feeder-free conditions on hESC-qualified Matrigel (Becton Dickinson) in mTeSR (Stem Cell Technologies) and differentiated as described by Yang et al. 37 Briefly, hESCs were detached using trypsin (Invitrogen) and transferred to low-attachment plates to all…”
InfluentialMuscular Thin Films for Building Actuators and Powering Devices
Feinberg, A. W., Feigel, A., Shevkoplyas, S. S., Sheehy, S., Whitesides, G. M., & Parker, K. K. (2007) · Science · doi:10.1126/science.1146885 · Cited by 765
Brutsaert, D. L. (2003) · Physiological Reviews · doi:10.1152/physrev.00017.2002 · Cited by 697 · cited 1×
“The heterogeneous cellular composition of the heart includes CM, endothelial cells, fibroblasts, and smooth muscle cells.(39,40) In a previous study, it was also shown that the lack of cardiac fibroblasts in CM culture systems negatively affect the alignment, elongation, and network formation of CM.”
Topographical control of cell behaviour: II. multiple grooved substrata
Clark, P., Connolly, P., Curtis, A. S. G., Dow, J. A. T., & Wilkinson, C. D. W. (1990) · Development · doi:10.1242/dev.108.4.635 · Cited by 682
Nanoscale cues regulate the structure and function of macroscopic cardiac tissue constructs
Kim, D.-H., Lipke, E. A., Kim, P., Cheong, R., Thompson, S., Delannoy, M., Suh, K.-Y., Tung, L., & Levchenko, A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0906504107 · Cited by 611 · cited 3×
“supporting myocardial extracellular matrix (ECM) is composed of aligned fibrils on the order of 100 nm in diameter with considerable variations in distances between the fibrals.(15) However, most current nanofabrication approaches are complex and expensive (e-beam lithography and nanoimprint lithography) and therefore…”
Development of a drug screening platform based on engineered heart tissue
Hansen, A., Eder, A., Bönstrup, M., Flato, M., Mewe, M., Schaaf, S., Aksehirlioglu, B., Schwörer, A., Uebeler, J., & Eschenhagen, T. (2010) · Circulation Research · doi:10.1161/circresaha.109.211458 · Cited by 510
Chen, A., Lieu, D. K., Freschauf, L., Lew, V., Sharma, H., Wang, J., Nguyen, D., Karakikes, I., Hajjar, R. J., Gopinathan, A., et al. (2011) · Advanced Materials · doi:10.1002/adma.201103463 · Cited by 122
Self-citationNuclear morphology and deformation in engineered cardiac myocytes and tissues
Bray, M.-A. P., Adams, W. J., Geisse, N. A., Feinberg, A. W., Sheehy, S. P., & Parker, K. K. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.028 · Cited by 107
Control of myocyte remodeling in vitro with engineered substrates
Geisse, N. A., Sheehy, S. P., & Parker, K. K. (2009) · In Vitro Cellular & Developmental Biology - Animal · doi:10.1007/s11626-009-9182-9 · Cited by 82
Cited by
Functional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment
Huang, G., Li, F., Zhao, X., Ma, Y., Li, Y., Lin, M., Jin, G., Lu, T. J., Genin, G. M., & Xu, F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00094 · Cited by 825
Nanotopography-guided tissue engineering and regenerative medicine
Kim, H. N., Jiao, A., Hwang, N. S., Kim, M. S., Kang, D. H., Kim, D.-H., & Suh, K.-Y. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.07.014 · Cited by 404
Tissue Engineering Approaches in the Design of Healthy and Pathological In Vitro Tissue Models
Caddeo, S., Boffito, M., & Sartori, S. (2017) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2017.00040 · Cited by 285
Bae, W., Kim, H. N., Kim, D., Park, S., Jeong, H. E., & Suh, K. (2014) · Advanced Materials · doi:10.1002/adma.201303412 · Cited by 265
In vitro cardiac tissue models: Current status and future prospects
Mathur, A., Ma, Z., Loskill, P., Jeeawoody, S., & Healy, K. E. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.09.011 · Cited by 187
“Cell alignment can be controlled by surface topography [46-50] or by micromolding with microchannels fabricated from PDMS [51-53].”
BackgroundChen, A., Lieu, D. K., Freschauf, L., Lew, V., Sharma, H., Wang, J., Nguyen, D., Karakikes, I., Hajjar, R. J., Gopinathan, A., et al. (2011) · Advanced Materials · doi:10.1002/adma.201103463 · Cited by 122
Self-citationKeung, W., Boheler, K. R., & Li, R. A. (2014) · Stem Cell Research & Therapy · doi:10.1186/scrt406 · Cited by 87
Self-citationTopographical modulation of macrophage phenotype by shrink-film multi-scale wrinkles
Wang, T., Luu, T. U., Chen, A., Khine, M., & Liu, W. F. (2016) · Biomaterials Science · doi:10.1039/c6bm00224b · Cited by 77
Self-citationWang, J., Chen, A., Lieu, D. K., Karakikes, I., Chen, G., Keung, W., Chan, C. W., Hajjar, R. J., Costa, K. D., Khine, M., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.039 · Cited by 69
Self-citationKeung, W., Chan, P. K. W., Backeris, P. C., Lee, E. K., Wong, N., Wong, A. O. T., Wong, G. K. Y., Chan, C. W. Y., Fermini, B., Costa, K. D., et al. (2019) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.1385 · Cited by 54
Self-citationShum, A. M. Y., Che, H., Wong, A. O., Zhang, C., Wu, H., Chan, C. W. Y., Costa, K., Khine, M., Kong, C., & Li, R. A. (2017) · Advanced Materials · doi:10.1002/adma.201602448 · Cited by 37
Self-citationMohammadi, M. H., Okhovatian, S., Savoji, H., Campbell, S. B., Lai, B. F. L., Wu, J., Pascual‐Gil, S., Bannerman, D., Rafatian, N., Li, R., et al. (2022) · Advanced Biology · doi:10.1002/adbi.202101165 · Cited by 28
Self-citationCheng, S., Brenière-Letuffe, D., Ahola, V., Wong, A. O. T., Keung, H. Y., Gurung, B., Zheng, Z., Costa, K. D., Lieu, D. K., Keung, W., et al. (2023) · iScience · doi:10.1016/j.isci.2023.106302 · Cited by 23
Self-citation
Metadata
- Authors
- Luna, J. I., Ciriza, J., Garcia-Ojeda, M. E., Kong, M., Herren, A., Lieu, D. K., Li, R. A., Fowlkes, C. C., Khine, M., & McCloskey, K. E.
- Venue
- Tissue Engineering Part C: Methods
- Publisher
- SAGE Publications
- Published
- 2011-05
- Volume
- 17
- Issue
- 5
- Pages
- 579-588
- ISSN
- 1937-3384 (ISSN-L)
- 1937-3392
- OpenAlex
- W2051834749
- Cited by
- 80
- References
- 9
- FWCI
- 3.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.