Cited by 19Non-Invasive Vital Sign MonitoringAdvanced Sensor and Energy Harvesting MaterialsWireless Body Area Networks

Wearable Sensor Glove Based on Conducting Fabric Using Electrodermal Activity and Pulse-Wave Sensors for e-Health Application

Lee, Youngbum, Lee, Byungwoo, Lee, Myoungho·2010·Telemedicine and e-Health

Abstract

Improvement of the quality and efficiency of health in medicine, both at home and the hospital, calls for improved sensors that might be included in a common carrier such as a wearable sensor device to measure various biosignals and provide healthcare services that use e-health technology. Designed to be user-friendly, smart clothes and gloves respond well to the end users for health monitoring. This study describes a wearable sensor glove that is equipped with an electrodermal activity (EDA) sensor, pulse-wave sensor, conducting fabric, and an embedded system. The EDA sensor utilizes the relationship between drowsiness and the EDA signal. The EDA sensors were made using a conducting fabric instead of silver chloride electrodes, as a more practical and practically wearable device. The pulse-wave sensor measurement system, which is widely applied in oriental medicinal practices, is also a strong element in e-health monitoring systems. The EDA and pulse-wave signal acquisition module was constructed by connecting the sensor to the glove via a conductive fabric. The signal acquisition module is then connected to a personal computer that displays the results of the EDA and pulse-wave signal processing analysis and gives accurate feedback to the user. This system is designed for a number of applications for the e-health services, including drowsiness detection and oriental medicine.

Integrity signals

Registry

Crossref · 10.1089/tmj.2009.0039

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A negative correlation exists between peripheral skin temperature and chronic stress levels.

    “A negative correlation exists between peripheral skin temperature and chronic stress levels,96,97”
  • A glove-type device uses multiple hard sensors assembled on a single layer, resulting in poor wearing comfort due to low flexibility and large skin contact area.

    “For example, a glove-type device23 uses the multiple hard sensors assembled on a single layer, resulting in a poor wearing comfort due to low flexibility and large skin contact area.”

    From A Flexible and Wearable Human Stress Monitoring Patch (2016) · cites this paper as [23]

  • Peripheral skin temperature shows a negative relationship with the chronic stress level.

    “Peripheral skin temperature shows negative relationship2340 with the chronic stress level.”

    From A Flexible and Wearable Human Stress Monitoring Patch (2016) · cites this paper as [23]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lee, Y., Lee, B., & Lee, M.
Affiliations
  • Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea.
  • Yonsei University (KR)
Venue
Telemedicine and e-Health
Published
2010-03
Volume
16
Issue
2
Pages
209-217
ISSN
  • 1530-5627 (ISSN-L)
  • 1556-3669
OpenAlex
W2054764142
Cited by
19
References
1
Citations by year
2024: 2 · 2022: 1 · 2021: 1 · 2020: 2 · 2019: 4 · 2018: 1 · 2017: 1 · 2016: 4 · 2015: 2 · 2014: 1
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
  • Telemedicine Journal and e-Health (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
electrodermal activity, e-health, drowsiness detection, biosignal monitoring, smart clothing, embedded systems, oriental medicine
MeSH terms
Clothing, Feasibility Studies, Humans, Ergonomics, Microelectrodes, Monitoring, Physiologic, Occupational Medicine, Skin Physiological Phenomena, Telemedicine, Ion-Selective Electrodes, Electrophysiological Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review