Wearable Sensor Glove Based on Conducting Fabric Using Electrodermal Activity and Pulse-Wave Sensors for e-Health Application
Abstract
Improvement of the quality and efficiency of health in medicine, both at home and the hospital, calls for improved sensors that might be included in a common carrier such as a wearable sensor device to measure various biosignals and provide healthcare services that use e-health technology. Designed to be user-friendly, smart clothes and gloves respond well to the end users for health monitoring. This study describes a wearable sensor glove that is equipped with an electrodermal activity (EDA) sensor, pulse-wave sensor, conducting fabric, and an embedded system. The EDA sensor utilizes the relationship between drowsiness and the EDA signal. The EDA sensors were made using a conducting fabric instead of silver chloride electrodes, as a more practical and practically wearable device. The pulse-wave sensor measurement system, which is widely applied in oriental medicinal practices, is also a strong element in e-health monitoring systems. The EDA and pulse-wave signal acquisition module was constructed by connecting the sensor to the glove via a conductive fabric. The signal acquisition module is then connected to a personal computer that displays the results of the EDA and pulse-wave signal processing analysis and gives accurate feedback to the user. This system is designed for a number of applications for the e-health services, including drowsiness detection and oriental medicine.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A negative correlation exists between peripheral skin temperature and chronic stress levels.
“A negative correlation exists between peripheral skin temperature and chronic stress levels,96,97”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [96]
A glove-type device uses multiple hard sensors assembled on a single layer, resulting in poor wearing comfort due to low flexibility and large skin contact area.
“For example, a glove-type device23 uses the multiple hard sensors assembled on a single layer, resulting in a poor wearing comfort due to low flexibility and large skin contact area.”
From A Flexible and Wearable Human Stress Monitoring Patch (2016) · cites this paper as [23]
Peripheral skin temperature shows a negative relationship with the chronic stress level.
“Peripheral skin temperature shows negative relationship2340 with the chronic stress level.”
From A Flexible and Wearable Human Stress Monitoring Patch (2016) · cites this paper as [23]
Cites
Design of Digital Hardware System for Pulse Signals
Lee, J., Kim, J., & Lee, M. (2001) · Journal of Medical Systems · doi:10.1023/a:1011975727571 · Cited by 9 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Wearable sensors for monitoring the physiological and biochemical profile of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0150-9 · Cited by 537 · see citing works
Innovations in Electrodermal Activity Data Collection and Signal Processing: A Systematic Review
Posada-Quintero, H. F., & Chon, K. H. (2020) · Sensors · doi:10.3390/s20020479 · Cited by 525 · see citing works
Wearable Sensing Technology Applications in Construction Safety and Health
Ahn, C. R., Lee, S. H., Sun, C., Jebelli, H., Yang, K., & Choi, B. (2019) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0001708 · Cited by 290 · see citing works
Shameer, K., Badgeley, M. A., Miotto, R., Glicksberg, B. S., Morgan, J. W., & Dudley, J. T. (2017) · Briefings in Bioinformatics · doi:10.1093/bib/bbv118 · Cited by 198 · see citing works
A Flexible and Wearable Human Stress Monitoring Patch
Yoon, S., Sim, J. K., & Cho, Y.-H. (2016) · Scientific Reports · doi:10.1038/srep23468 · Cited by 151 · see citing works
Machine Learning Based Solutions for Real-Time Stress Monitoring
Nath, R. K., Thapliyal, H., Caban‐Holt, A., & Mohanty, S. P. (2020) · IEEE Consumer Electronics Magazine · doi:10.1109/mce.2020.2993427 · Cited by 98 · see citing works
Current trends and opportunities in the methodology of electrodermal activity measurement
Tronstad, C., Amini, M., Bach, D. R., & Martinsen, Ø. G. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac5007 · Cited by 88 · see citing works
Wireless Wearable Magnetometer-Based Sensor for Sleep Quality Monitoring
Milici, S., Lázaro, A., Villarino, R., Girbau, D., & Magnarosa, M. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2791400 · Cited by 83 · see citing works
E-textiles in Clinical Rehabilitation: A Scoping Review
Fleury, A., Sugar, M., & Chau, T. T. (2015) · Electronics · doi:10.3390/electronics4010173 · Cited by 70 · see citing works
Wearable Sensors, Data Processing, and Artificial Intelligence in Pregnancy Monitoring: A Review
Liu, L., Pu, Y., Fan, J., Yan, Y., Liu, W., Luo, K., Wang, Y., Zhao, G., Chen, T. P., Poenar, D. P., et al. (2024) · Sensors · doi:10.3390/s24196426 · Cited by 67 · see citing works
Skin Admittance Measurement for Emotion Recognition: A Study over Frequency Sweep
Greco, A., Lanatá, A., Citi, L., Vanello, N., Valenza, G., & Scilingo, E. (2016) · Electronics · doi:10.3390/electronics5030046 · Cited by 55 · see citing works
Sánchez-Reolid, R., de la Rosa, F. L., López, M. T., & Fernández‐Caballero, A. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.103203 · Cited by 43 · see citing works
Clinical translation of biomedical sensors for sports medicine
Seshadri, D. R., Magliato, S. N., Voos, J. E., & Drummond, C. K. (2019) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2019.1612474 · Cited by 21 · see citing works
Recent Progress in Biosensors for Depression Monitoring—Advancing Personalized Treatment
Yin, J., Jia, X., Li, H., Zhao, B., Yang, Y. A., & Ren, T. (2024) · Biosensors · doi:10.3390/bios14090422 · Cited by 14 · see citing works
On-chip flexible multi-layer sensors for Human stress monitoring
Yoon, S., Sim, J. K., & Cho, Y.-H. (2014) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2014.6985133 · Cited by 6 · see citing works
Medical Virtual Instrumentation for Personalized Health Monitoring: A Systematic Review
Adeluyi, O., & Lee, J. (2015) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.6.4.739 · Cited by 5 · see citing works
Chapter 15 Behavioral signal processing and autism
Bone, D., Chaspari, T., & Narayanan, S. S. (2016) · CRC Press eBooks · doi:10.1201/9781315371375-16 · Cited by 3 · see citing works
Wearable Electronics and Embedded Computing Systems for Biomedical Applications
Scilingo, E., & Valenza, G. (2017) · MDPI eBooks · doi:10.3390/books978-3-03842-387-4 · Cited by 1 · see citing works
Efficacy of e-health and smart devices in occupational health and safety: a literature review
Garsi, J., Cousin-Rénié, M.-A., Godon, A.-S., & Dab, W. (2019) · Environnement Risques Santé · doi:10.1684/ers.2019.1369
- Authors
- Lee, Y., Lee, B., & Lee, M.
- Affiliations
- Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea.
- Yonsei University (KR)
- ORCID
- Lee, Myoungho
- Venue
- Telemedicine and e-Health
- Publisher
- SAGE Publications
- Published
- 2010-03
- Volume
- 16
- Issue
- 2
- Pages
- 209-217
- ISSN
- 1530-5627 (ISSN-L)
- 1556-3669
- OpenAlex
- W2054764142
- Cited by
- 19
- References
- 1
- Citations by year
- 2024: 2 · 2022: 1 · 2021: 1 · 2020: 2 · 2019: 4 · 2018: 1 · 2017: 1 · 2016: 4 · 2015: 2 · 2014: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Telemedicine Journal and e-Health (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- electrodermal activity, e-health, drowsiness detection, biosignal monitoring, smart clothing, embedded systems, oriental medicine
- MeSH terms
- Clothing, Feasibility Studies, Humans, Ergonomics, Microelectrodes, Monitoring, Physiologic, Occupational Medicine, Skin Physiological Phenomena, Telemedicine, Ion-Selective Electrodes, Electrophysiological Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review