INTRODUCTION: This study investigates the accuracy of a heart rate (HR) measurement algorithm applied to a pulse wave. This was based on video signals recorded with a smartphone. The results of electrocardiographic HR and standard linear heart rate variability (HRV) analysis were used for reference. MATERIALS AND METHODS: On a total of 68 subjects, an electrocardiogram (ECG) and the pulse curve were simultaneously recorded on an Apple iPhone 4S. The HR was measured using an algorithm developed by the authors that works according to a method combining the detection of the steepest slope of every pulse wave with the correlation to an optimized pulse wave pattern. RESULTS: The results of the HR measured by pulse curves were extremely consistent (R > 0.99) with the HR measured on ECGs. For most standard linear HRV parameters as well, high correlations of R ≥ 0.90 in the analysis were achieved in the time and frequency domain. CONCLUSION: In conclusion, the overall accuracy of HR and HRV indices of pulse wave analysis, based on video signals of a smartphone, with the developed algorithm was sufficient for preclinical screening applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/tmj.2015.0212

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 60

Metadata

Authors
Koenig, N., Seeck, A., Eckstein, J., Mainka, A., Huebner, T., Voss, A., & Weber, S.
Venue
Telemedicine and e-Health
Published
2016-08
Volume
22
Issue
8
Pages
631-636
ISSN
  • 1530-5627 (ISSN-L)
  • 1556-3669
OpenAlex
W2291943979
Cited by
60
References
6
FWCI
2.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.