CoChat

Accuracy of Smartphone-Based Pulse Oximetry Compared with Hospital-Grade Pulse Oximetry in Healthy Children

Tomlinson, Sarah, Behrmann, Sydney, Cranford, James, Louie, Marisa, Hashikawa, Andrew · 2018 · Telemedicine and e-Health
Cited by 106

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background: Pulse oximetry, a ubiquitous, noninvasive method to monitor oxygen saturation (SpO2), requires larger, nonportable equipment. Smartphone pulse oximeter applications (apps) provide a portable, cost-effective option, but are untested in children. We hypothesize that smartphone pulse oximetry will not be inferior to standard pulse oximetry measured in healthy children. Materials and Methods: Two main types of pulse oximetry apps, a camera-based app (CBA) that uses a phone camera flash and lens and a probe-based app (PBA) that uses an external plug-in probe, were compared with standard pulse oximetry measured in children ages 2–13 years without a respiratory complaint and a triage SpO2 ≥97% seen in a pediatric Emergency Department. Two investigators obtained heart rate and SpO2 using each app. Inter-rater reliability was tested using interclass correlations (ICCs), and Bland–Altman method was used to compare app values to triage measurements. Results: Eighty-one patients were enrolled. ICC for SpO2 for PBA and CBA were 0.73 and −0.24, respectively. The 95% limits of agreement between the PBA SpO2 and triage SpO2 were −2.8 to +2.5 compared with −4.1 to +3.5 for the CBA SpO2 and triage SpO2. Mean differences between triage SpO2 and the PBA SpO2 (−0.17%) and triage SpO2 and CBA SpO2 (−0.33%) were not statistically significant. Discussion and Conclusions: Smartphone-based pulse oximetry is not inferior to standard pulse oximetry in pediatric patients without hypoxia. Reliability was superior for PBA compared with CBA, with more precise agreement for the PBA compared with the CBA. Future studies should test pulse oximetry apps in a hypoxic pediatric population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/tmj.2017.0166

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 106

Metadata

Authors
Tomlinson, S., Behrmann, S., Cranford, J., Louie, M., & Hashikawa, A.
Venue
Telemedicine and e-Health
Published
2018-07
Volume
24
Issue
7
Pages
527-535
ISSN
  • 1530-5627 (ISSN-L)
  • 1556-3669
OpenAlex
W2771339634
Cited by
106
References
4
FWCI
3.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of Smartphone-Based Pulse Oximetry Compared with Hospital-Grade Pulse Oximetry in Healthy Children. https://app.cochat.ai/papers/10.1089/tmj.2017.0166
The paper
Tomlinson, S., Behrmann, S., Cranford, J., Louie, M., & Hashikawa, A. (2018). Accuracy of Smartphone-Based Pulse Oximetry Compared with Hospital-Grade Pulse Oximetry in Healthy Children. Telemedicine and e-Health. https://doi.org/10.1089/tmj.2017.0166

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.