3.1 Using ICA for the Analysis of Multi-Channel EEG Data
Abstract
Independent component analysis (ICA) is a linear decomposition technique that aims to reveal the underlying statistical sources of mixed signals. The EEG signal consists of a mixture of various brain and non-brain contributions. Accordingly, a valid and powerful unmixing tool promises a better, more accessible representation of the statistical sources contributing to the mixed recorded signal. ICA, being potentially such a tool, may help in the detection of signal sources that cannot be identified on the raw data level alone using other, more conventional techniques. The application of ICA to EEG signals has become popular, as it provides two key features: it is a powerful way to remove artifacts from EEG data, and it helps to disentangle otherwise mixed brain signals. This chapter is concerned with evaluating and optimizing EEG decompositions by means of ICA. First, it discusses typical ICA results with reference to artifact- and brain-related components. Then, it elaborates on different EEG pre-processing steps, considered in light of the statistical assumptions underlying ICA. As such, the motivation for the chapter is to provide some practical guidelines for those researchers who wish to successfully decompose multi-channel EEG recordings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759
Dynamic Brain Sources of Visual Evoked Responses
Makeig, S., Westerfield, M., Jung, T.-P., Enghoff, S., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2002) · Science · doi:10.1126/science.1066168 · Cited by 1,630
Cited by
Machine Learning for Predicting Epileptic Seizures Using EEG Signals: A Review
Rasheed, K., Qayyum, A., Qadir, J., Sivathamboo, S., Kwan, P., Kuhlmann, L., O'Brien, T., & Razi, A. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.3008792 · Cited by 409
On the influence of high-pass filtering on ICA-based artifact reduction in EEG-ERP
Winkler, I., Debener, S., Muller, K.-R., & Tangermann, M. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319296 · Cited by 407
Self-citationVisual activation of auditory cortex reflects maladaptive plasticity in cochlear implant users
Sandmann, P., Dillier, N., Eichele, T., Meyer, M., Kegel, A., Pascual-Marqui, R. D., Marcar, V. L., Jäncke, L., & Debener, S. (2012) · Brain · doi:10.1093/brain/awr329 · Cited by 259
Self-citationFocus of attention modulates the heartbeat evoked potential
Petzschner, F. H., Weber, L. A., Wellstein, K. V., Paolini, G., Do, C. T., & Stephan, K. E. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.11.037 · Cited by 248
Adolescent cognitive control, theta oscillations, and social observation
Buzzell, G. A., Barker, T. V., Troller-Renfree, S. V., Bernat, E. M., Bowers, M. E., Morales, S., Bowman, L. C., Henderson, H. A., Pine, D. S., & Fox, N. A. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.04.077 · Cited by 65
Metadata
- Authors
- Debener, S., Thorne, J., Schneider, T. R., & Viola, F. C.
- Venue
- Simultaneous EEG and fMRI
- Publisher
- Oxford University PressNew York
- Published
- 2010-04-30
- Pages
- 121-134
- OpenAlex
- W2503208244
- Cited by
- 169
- References
- 2
- FWCI
- 10.67
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3.1 Using ICA for the Analysis of Multi-Channel EEG Data. https://app.cochat.ai/papers/10.1093/acprof:oso/9780195372731.003.0008
- The paper
- Debener, S., Thorne, J., Schneider, T. R., & Viola, F. C. (2010). 3.1 Using ICA for the Analysis of Multi-Channel EEG Data. Simultaneous EEG and fMRI. https://doi.org/10.1093/acprof%3Aoso/9780195372731.003.0008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.