CoChat

HDL Cholesterol Quantitation by Phosphotungstate-Mg2+ and by Dextran Sulfate-Mn2+-Polyethylene Glycol Precipitation, Both with Enzymic Cholesterol Assay Compared with the Lipid Research Method

Russell Warnick, G., Mayfield, Cathy, Benderson, Joan, Chen, Jung-Shou, Albers, John J. · 1982 · American Journal of Clinical Pathology
Cited by 95

The DOI matches its Crossref record.

Abstract

Two methods using commercial kits for high density lipoprotein (HDL) cholesterol quantitation were compared with the Lipid Research Clinics (LRC) procedures. HDL cholesterol quantitations on 50 patient specimens by the Lancer HDL cholesterol Rapid Stat Kit (Lancer) with phosphotungstate-Mg2+ precipitation and enzymic cholesterol assay averaged 424 mg/L, and by a method with dextran sulfate-Mn2+-polyethylene glycol (dextran sulfate) precipitation and enzymic cholesterol assay averaged 474 mg/L. By comparison, the LRC method (heparin-Mn2+ precipitation combined with a Liebermann-Burchard reagent cholesterol assay) averaged 478 mg/L. Supernates obtained by the three precipitation methods had similar cholesterol values when analyzed by the LRC assay, suggesting that the observed differences were primarily due to differences between the cholesterol assays. Results were consistent with underestimation by the enzymic assay of cholesterol in the supernates, offset by a positive interference of Mn2+ in the dextran sulfate-produced supernates. Among-day CVs of 4-5% were observed for the Lancer method, and 6-7% for the dextran sulfate method. Sedimentation of precipitates in hypertriglyceridemic specimens was excellent by both methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ajcp/78.5.718

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Russell Warnick, G., Mayfield, C., Benderson, J., Chen, J.-S., & Albers, J. J.
Venue
American Journal of Clinical Pathology
Published
1982-11-01
Volume
78
Issue
5
Pages
718-723
ISSN
  • 0002-9173 (ISSN-L)
  • 1943-7722
OpenAlex
W165073693
Cited by
95
References
0
FWCI
0.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.