CoChat

Evaluation of the 24-Hour Recall as a Reference Instrument for Calibrating Other Self-Report Instruments in Nutritional Cohort Studies: Evidence From the Validation Studies Pooling Project

Open access
Freedman, Laurence S., Commins, John M., Willett, Walter, Tinker, Lesley F., Spiegelman, Donna, Rhodes, Donna, Potischman, Nancy, Neuhouser, Marian L., Moshfegh, Alanna J., Kipnis, Victor, Baer, David J., Arab, Lenore, Prentice, Ross L., Subar, Amy F. · 2017 · American Journal of Epidemiology
Cited by 62

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Calibrating dietary self-report instruments is recommended as a way to adjust for measurement error when estimating diet-disease associations. Because biomarkers available for calibration are limited, most investigators use self-reports (e.g., 24-hour recalls (24HRs)) as the reference instrument. We evaluated the performance of 24HRs as reference instruments for calibrating food frequency questionnaires (FFQs), using data from the Validation Studies Pooling Project, comprising 5 large validation studies using recovery biomarkers. Using 24HRs as reference instruments, we estimated attenuation factors, correlations with truth, and calibration equations for FFQ-reported intakes of energy and for protein, potassium, and sodium and their densities, and we compared them with values derived using biomarkers. Based on 24HRs, FFQ attenuation factors were substantially overestimated for energy and sodium intakes, less for protein and potassium, and minimally for nutrient densities. FFQ correlations with truth, based on 24HRs, were substantially overestimated for all dietary components. Calibration equations did not capture dependencies on body mass index. We also compared predicted bias in estimated relative risks adjusted using 24HRs as reference instruments with bias when making no adjustment. In disease models with energy and 1 or more nutrient intakes, predicted bias in estimated nutrient relative risks was reduced on average, but bias in the energy risk coefficient was unchanged.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/aje/kwx039

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 62

Metadata

Authors
Freedman, L. S., Commins, J. M., Willett, W., Tinker, L. F., Spiegelman, D., Rhodes, D., Potischman, N., Neuhouser, M. L., Moshfegh, A. J., Kipnis, V., Baer, D. J., Arab, L., Prentice, R. L., & Subar, A. F.
Venue
American Journal of Epidemiology
Published
2017-04-10
Volume
186
Issue
1
Pages
73-82
ISSN
  • 0002-9262 (ISSN-L)
  • 1476-6256
OpenAlex
W2606842648
Cited by
62
References
5
FWCI
5.89
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the 24-Hour Recall as a Reference Instrument for Calibrating Other Self-Report Instruments in Nutritional Cohort Studies: Evidence From the Validation Studies Pooling Project. https://app.cochat.ai/papers/10.1093/aje/kwx039
The paper
Freedman, L. S., Commins, J. M., Willett, W., Tinker, L. F., Spiegelman, D., Rhodes, D., Potischman, N., Neuhouser, M. L., Moshfegh, A. J., Kipnis, V., Baer, D. J., Arab, L., Prentice, R. L., & Subar, A. F. (2017). Evaluation of the 24-Hour Recall as a Reference Instrument for Calibrating Other Self-Report Instruments in Nutritional Cohort Studies: Evidence From the Validation Studies Pooling Project. American Journal of Epidemiology. https://doi.org/10.1093/aje/kwx039

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.