An Assessment of the Accuracy of Home Blood Pressure Monitors When Used in Device Owners
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To examine the accuracy of home blood pressure (BP) devices, on their owners, compared to auscultatory reference standard BP measurements. METHODS: Eighty-five consecutive consenting subjects ≥18 years of age, who owned an oscillometric home BP device (wrist or upper-arm device), with BP levels between 80–220/50–120 mm Hg, and with arm circumferences between 25–43 cm were studied. Pregnancy and atrial fibrillation were exclusion criteria. Device measurements from each subject’s home BP device were compared to simultaneous 2-observer auscultation using a mercury sphygmomanometer. Between-group mean comparisons were conducted using paired t-tests. The proportion of patients with device-to-auscultatory differences of ≥5, 10, and 15 mm Hg were tabulated and predictors of systolic and diastolic BP differences were identified using linear regression. RESULTS: Mean age was 66.4 ± 11.0 years, mean arm circumference was 32.7 ± 3.7 cm, 54% were female and 78% had hypertension. Mean BPs were 125.7 ± 14.0/73.9 ± 10.4 mm Hg for home BP devices vs. 129.0 ± 14.7/72.9 ± 9.3 for auscultation (difference of −3.3 ± 7.3/0.9 ± 6.1; P values <0.0001 for systolic and 0.17 for diastolic). The proportion of devices with systolic or diastolic BP differences from auscultation of ≥5, 10, and 15 mm Hg was 69%, 29%, and 7%, respectively. Increasing arm circumference was a statistically significant predictor of higher systolic (parameter estimate 0.61 per cm increase; P value 0.004) and diastolic (0.38; 0.03) BP. CONCLUSIONS: Although mean differences from 2-observer auscultation were acceptable, when tested on their owners, most home BP devices were not accurate to within 5 mm Hg. Ensuring acceptable accuracy of the device-owner pairing should be prioritized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Oscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
Stergiou, G. S., Lourida, P., Tzamouranis, D., & Baibas, N. M. (2009) · Journal of Human Hypertension · doi:10.1038/jhh.2009.20 · Cited by 74 · cited 1×
“Diastolic 8 (21) 2 (5) 1 (3) Soft cuff (n = 48) Systolic or diastolic 31 (65) 12 (25) 5 (10) Systolic 26 (54) 12 (25) 5 (10) Diastolic 11 (23) 2 (4) 0 (0) Hard cuff (n = 37) Systolic or diastolic 28 (76) 13 (35) 1 (3) Systolic 20 (54) 5 (14) 0 (0) Diastolic 15 (41) 8 (21) 1 (3) Table 4.”
Amoore, J. N., Lemesre, Y., Murray, I. C., Mieke, S., King, S. T., Smith, F. E., & Murray, A. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282f06ec7 · Cited by 56
Cited by
Practice Bulletin No. 183: postpartum hemorrhage
(2017) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002351 · Cited by 1,406
ACOG Practice Bulletin No. 203: Chronic Hypertension in Pregnancy
(2019) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000003020 · Cited by 871
Management of Hypertension in Chronic Kidney Disease
Pugh, D., Gallacher, P. J., & Dhaun, N. (2019) · Drugs · doi:10.1007/s40265-019-1064-1 · Cited by 401
Sharman, J. E., O’Brien, E., Alpert, B., Schutte, A. E., Delles, C., Hecht Olsen, M., Asmar, R., Atkins, N., Barbosa, E., Calhoun, D., et al. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002246 · Cited by 139
Self-citationHodgkinson, J. A., Lee, M.-M., Milner, S., Bradburn, P., Stevens, R., Hobbs, F. R., Koshiaris, C., Grant, S., Mant, J., & McManus, R. J. (2020) · British Journal of General Practice · doi:10.3399/bjgp20x710381 · Cited by 52
“19 However, a Korean study 20 using the same methodology found monitor failure rates of 15% — similar to those in the study presented here — and that inaccuracy was more common in unvalidated devices (19%, 25/130) than those that were validated (7%, 6/82).”
Metadata
- Authors
- Ringrose, J. S., Polley, G., McLean, D., Thompson, A., Morales, F., & Padwal, R.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-04-19
- Volume
- 30
- Issue
- 7
- Pages
- 683-689
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W2606125596
- Cited by
- 64
- References
- 4
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Assessment of the Accuracy of Home Blood Pressure Monitors When Used in Device Owners. https://app.cochat.ai/papers/10.1093/ajh/hpx041
- The paper
- Ringrose, J. S., Polley, G., McLean, D., Thompson, A., Morales, F., & Padwal, R. (2017). An Assessment of the Accuracy of Home Blood Pressure Monitors When Used in Device Owners. American Journal of Hypertension. https://doi.org/10.1093/ajh/hpx041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.