CoChat

An Assessment of the Accuracy of Home Blood Pressure Monitors When Used in Device Owners

Ringrose, Jennifer S., Polley, Gina, McLean, Donna, Thompson, Ann, Morales, Fraulein, Padwal, Raj · 2017 · American Journal of Hypertension
Cited by 64

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To examine the accuracy of home blood pressure (BP) devices, on their owners, compared to auscultatory reference standard BP measurements. METHODS: Eighty-five consecutive consenting subjects ≥18 years of age, who owned an oscillometric home BP device (wrist or upper-arm device), with BP levels between 80–220/50–120 mm Hg, and with arm circumferences between 25–43 cm were studied. Pregnancy and atrial fibrillation were exclusion criteria. Device measurements from each subject’s home BP device were compared to simultaneous 2-observer auscultation using a mercury sphygmomanometer. Between-group mean comparisons were conducted using paired t-tests. The proportion of patients with device-to-auscultatory differences of ≥5, 10, and 15 mm Hg were tabulated and predictors of systolic and diastolic BP differences were identified using linear regression. RESULTS: Mean age was 66.4 ± 11.0 years, mean arm circumference was 32.7 ± 3.7 cm, 54% were female and 78% had hypertension. Mean BPs were 125.7 ± 14.0/73.9 ± 10.4 mm Hg for home BP devices vs. 129.0 ± 14.7/72.9 ± 9.3 for auscultation (difference of −3.3 ± 7.3/0.9 ± 6.1; P values <0.0001 for systolic and 0.17 for diastolic). The proportion of devices with systolic or diastolic BP differences from auscultation of ≥5, 10, and 15 mm Hg was 69%, 29%, and 7%, respectively. Increasing arm circumference was a statistically significant predictor of higher systolic (parameter estimate 0.61 per cm increase; P value 0.004) and diastolic (0.38; 0.03) BP. CONCLUSIONS: Although mean differences from 2-observer auscultation were acceptable, when tested on their owners, most home BP devices were not accurate to within 5 mm Hg. Ensuring acceptable accuracy of the device-owner pairing should be prioritized.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ajh/hpx041

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 64

Metadata

Authors
Ringrose, J. S., Polley, G., McLean, D., Thompson, A., Morales, F., & Padwal, R.
Venue
American Journal of Hypertension
Published
2017-04-19
Volume
30
Issue
7
Pages
683-689
ISSN
  • 0895-7061 (ISSN-L)
  • 1941-7225
OpenAlex
W2606125596
Cited by
64
References
4
FWCI
4.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Assessment of the Accuracy of Home Blood Pressure Monitors When Used in Device Owners. https://app.cochat.ai/papers/10.1093/ajh/hpx041
The paper
Ringrose, J. S., Polley, G., McLean, D., Thompson, A., Morales, F., & Padwal, R. (2017). An Assessment of the Accuracy of Home Blood Pressure Monitors When Used in Device Owners. American Journal of Hypertension. https://doi.org/10.1093/ajh/hpx041

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.