Time Delays in Transdermal Alcohol Concentrations Relative to Breath Alcohol Concentrations
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
AIMS: Monitors of transdermal alcohol concentration (TAC) provide an objective measurement of alcohol consumption that is less invasive than measurements in blood, breath or urine; however, there is a substantial time delay in the onset of TAC compared to blood or breath alcohol concentrations (BrACs). The current study examined the characteristics of the delay between peak TAC and peak BrAC. METHODS: Data was aggregated from three experimental laboratory studies (N = 61; 32 men, 29 women) in which participants wore a TAC monitor and BrAC was monitored while drinking one, two, three, four and five beers in the laboratory. Analyses examined the sex- and dose-related differences in peak BrAC and TAC, the time-to-peak BrAC and TAC, and time lag between the peak BrAC and TAC values. RESULTS: The times-to-peak were an increasing function of the number of beers consumed. At each level of beer consumption the peak TAC averaged lower than peak BrAC and times-to-peak TAC were longer than for BrAC. The time-to-peak BrAC and TAC was longer for women than men. The congruence between peak TAC and BrAC increased as a function of the beers consumed. No sex difference in the time lag between peak BrAC and TAC was detected. CONCLUSIONS: The congruence between TAC and BrAC and time lags between TAC and BrAC are related to the number of beers consumed. Peak values of TAC and BrAC became more congruent with higher doses but the time lag increased as a function of the amount of alcohol consumed. SHORT SUMMARY: The time delay (or lag) and congruence between transdermal vs. BrACs increases as the number of beers increases. Though sex differences are evident in peak transdermal and BrACs, no sex differences were evident in the time lag and the congruence between transdermal and breath alcohol concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Studies on a Wearable, Electronic, Transdermal Alcohol Sensor
Swift, R. M., Martin, C. S., Swette, L., LaConti, A., & Kackley, N. (1992) · Alcoholism: Clinical and Experimental Research · doi:10.1111/j.1530-0277.1992.tb00668.x · Cited by 114 · cited 3×
“However, a wide range of time lags have been reported and range from 1 to 2 h (Marques and McKnight, 2009), an average of 1 h and 27min (Swift et al., 1992), 2–3 h (Sakai et al.”
InfluentialTransdermal Alcohol Measurement for Estimation of Blood Alcohol Concentration
Swift, R. (2000) · Alcoholism: Clinical and Experimental Research · doi:10.1111/j.1530-0277.2000.tb02006.x · Cited by 101
Cited by
Tehrani, F., Teymourian, H., Wuerstle, B., Kavner, J., Patel, R., Furmidge, A., Aghavali, R., Hosseini-Toudeshki, H., Brown, C., Zhang, F., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00887-1 · Cited by 625
Eyeglasses-based tear biosensing system: Non-invasive detection of alcohol, vitamins and glucose
Sempionatto, J. R., Brazaca, L. C., García-Carmona, L., Bolat, G., Campbell, A. S., Martin, A., Tang, G., Shah, R., Mishra, R. K., Kim, J., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.04.058 · Cited by 315
Hauke, A., Simmers, P., Ojha, Y. R., Cameron, B. D., Ballweg, R., Zhang, T., Twine, N., Brothers, M., Gomez, E., & Heikenfeld, J. (2018) · Lab on a Chip · doi:10.1039/c8lc01082j · Cited by 156
Wearable electrochemical alcohol biosensors
Campbell, A. S., Kim, J., & Wang, J. (2018) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2018.05.014 · Cited by 140
Metadata
- Authors
- Karns-Wright, T. E., Roache, J. D., Hill-Kapturczak, N., Liang, Y., Mullen, J., & Dougherty, D. M.
- Venue
- Alcohol and Alcoholism
- Publisher
- Oxford University Press (OUP)
- Published
- 2016-08-13
- Volume
- 52
- Issue
- 1
- Pages
- 35-41
- ISSN
- 0735-0414 (ISSN-L)
- 1464-3502
- OpenAlex
- W2512193556
- Cited by
- 60
- References
- 2
- FWCI
- 9.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.