Studies on a Wearable, Electronic, Transdermal Alcohol Sensor

Swift, Robert M., Martin, Christopher S., Swette, Larry, LaConti, Anthony, Kackley, Nancy·1992·Alcoholism: Clinical and Experimental Research

Abstract

The measurement of alcohol consumption over long time periods is important for monitoring treatment outcome and for research applications. Giner, Inc. has developed a wearable device that senses ethanol vapor at the surface of the skin, using an electrochemical cell that produces a continuous current signal proportional to ethanol concentration. A thermistor monitors continuous contact of the sensor with the skin, and a data‐acquisition/logic circuit stores days of data recorded at 2‐ to 5‐min intervals. Testing of this novel ethanol sensor/recorder was conducted on nonalcoholic human subjects consuming known quantities of ethanol and on intoxicated alcoholic subjects. The transdermal sensor signal closely follows the pattern of the blood alcohol concentration curve, although with a delay. This paper describes the concept of electrochemical ethanol measurement and presents some of the clinical data collected in support of the sensor/recorder development.

Integrity signals

Registry

Crossref · 10.1111/j.1530-0277.1992.tb00668.x

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • These wearable transdermal alcohol sensor devices suffer from long time delays (0.5-2 h) compared to BAC estimated by breathalyzers.

    “However, these devices suffer from long time delays (0.5-2 h) compared to BAC estimated by breathalyzers.11”
  • Two wearable transdermal alcohol sensor devices (SCRAM, Giner WrisTAS) have been developed for detecting local ethanol vapor concentration in insensible perspiration over the skin, which is not secreted by sweat glands.

    “Two wearable transdermal alcohol sensor devices (SCRAM, Giner WrisTAS) have been developed for detecting local ethanol vapor concentration in insensible perspiration over the skin, which is not secreted by sweat glands.11,12”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Swift, R. M., Martin, C. S., Swette, L., LaConti, A., & Kackley, N.
Affiliations
  • Roger Williams Medical Center (US)
  • Brown University (US)
  • Giner (United States) (US)
Corresponding author
Swift, Robert M.
Venue
Alcoholism: Clinical and Experimental Research
Publisher
Wiley
Published
1992-08
Volume
16
Issue
4
Pages
721-725
ISSN
  • 0145-6008 (ISSN-L)
  • 1530-0277
OpenAlex
W1975331847
Cited by
114
References
24
Citations by year
2025: 1 · 2024: 10 · 2023: 3 · 2022: 11 · 2021: 9 · 2020: 8 · 2019: 9 · 2018: 9 · 2017: 4 · 2016: 5 · 2014: 9 · 2013: 1 · 2012: 3
FWCI
0.47
Type
journal article
Language
en
Open access
closed
Locations
  • Alcoholism Clinical and Experimental Research (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5r44aa007657-03)
  • National Institute on Alcohol Abuse and Alcoholism (2R44AA07657)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
Keywords
wearable devices, ethanol vapor, blood alcohol concentration, alcohol consumption monitoring, alcohol intoxication, alcoholism treatment outcomes
MeSH terms
Adult, Ethanol, Alcoholic Intoxication, Electrodes, Electrodiagnosis, Equipment Design, Female, Humans, Male, Metabolic Clearance Rate, Middle Aged, Monitoring, Physiologic, Reference Values, Skin

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review