CoChat

The Deposition of 0·5 µ Diameter Aerosols in the Lungs of Man

· 1967 · The Annals of Occupational Hygiene
Cited by 72

The DOI matches its Crossref record.

Abstract

A method is described for the measurement of the fractional deposition of aerosols in the lungs of man during steady-state breathing. The aerosol concentration was measured close to the mouth by a Tyndallometer with a small dead space and the inhaled and exhaled air volumes were measured with a spirometer. The factors affecting the deposition of unit density spheres of about 0·5 µ dia. were investigated in three normal subjects. The fractional deposition rose with increasing tidal volume and fell with increasing frequency of breathing. The effect of changes in the tidal volume was surprisingly small and the possible reasons for this are discussed. The deposition values obtained were lower than those previously reported in the literature and suggest that during exercise the fractional deposition of 0·5 µ dia. particles is about 10 per cent of the inhaled concentration at all work loads. The importance of distinguishing between the effects of changes in the depth of breathing and in the frequency of breathing in the design of aerosol inhalation experiments is stressed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/annhyg/10.3.161

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 72

Metadata

Venue
The Annals of Occupational Hygiene
Published
1967-07
Volume
10
Issue
3
Pages
161-74
ISSN
  • 0003-4878 (ISSN-L)
  • 1475-3162
OpenAlex
W2144739310
Cited by
72
References
0
FWCI
2.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Deposition of 0·5 µ Diameter Aerosols in the Lungs of Man. https://app.cochat.ai/papers/10.1093/annhyg/10.3.161
The paper
The Deposition of 0·5 µ Diameter Aerosols in the Lungs of Man. (1967). The Annals of Occupational Hygiene. https://doi.org/10.1093/annhyg/10.3.161

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.