Comparison of Four Nuclear Isolation Buffers for Plant DNA Flow Cytometry
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND AIMS: DNA flow cytometry requires preparation of suspensions of intact nuclei, which are stained using a DNA-specific fluorochrome prior to analysis. Various buffer formulas were developed to preserve nuclear integrity, protect DNA from degradation and facilitate its stoichiometric staining. Although nuclear isolation buffers differ considerably in chemical composition, no systematic comparison of their performance has been made until now. This knowledge is required to select the appropriate buffer for a given species and tissue. METHODS: Four common lysis buffers (Galbraith's, LB01, Otto's and Tris.MgCl2) were used to prepare samples from leaf tissues of seven plant species (Sedum burrito, Oxalis pes-caprae, Lycopersicon esculentum, Celtis australis, Pisum sativum, Festuca rothmaleri and Vicia faba). The species were selected to cover a wide range of genome sizes (1.30-26.90 pg per 2C DNA) and a variety of leaf tissue types. The following parameters were assessed: forward (FS) and side (SS) light scatters, fluorescence of propidium iodide-stained nuclei, coefficient of variation of DNA peaks, presence of debris background and the number of nuclei released from sample tissue. The experiments were performed independently by two operators and repeated on three different days. KEY RESULTS: Clear differences among buffers were observed. With the exception of O. pes-caprae, any buffer provided acceptable results for all species. LB01 and Otto's were generally the best buffers, with Otto's buffer providing better results in species with low DNA content. Galbraith's buffer led to satisfactory results and Tris.MgCl2 was generally the worst, although it yielded the best histograms in C. australis. A combined analysis of FS and SS provided a 'fingerprint' for each buffer. The variation between days was more significant than the variation between operators. CONCLUSIONS: Each lysis buffer tested responded to a specific problem differently and none of the buffers worked best with all species. These results expand our knowledge on nuclear isolation buffers and will facilitate selection of the most appropriate buffer depending on species, tissue type and the presence of cytosolic compounds interfering with DNA staining.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shapiro, H. M. (2003) · Wiley eBooks · doi:10.1002/0471722731 · Cited by 2,671
Rapid Flow Cytometric Analysis of the Cell Cycle in Intact Plant Tissues
Galbraith, D. W., Harkins, K. R., Maddox, J. M., Ayres, N. M., Sharma, D. P., & Firoozabady, E. (1983) · Science · doi:10.1126/science.220.4601.1049 · Cited by 1,946 · cited 5×
“We set out to compare four of the most common buffers that differ in chemical composition: Galbraith’s buffer (Galbraith et al., 1983), LB01 (Doležel et al., 1989), Otto’s buffer (Otto, 1992; Doležel and Göhde, 1995) and Tris.”
MethodInfluentialDoležel, J., Bartoš, J., Voglmayr, H., & Greilhuber, J. (2003) · Cytometry Part A · doi:10.1002/cyto.a.10013 · Cited by 1,071 · cited 4×
“S: burrito 2C nuclear DNA content pg ð Þ 1⁄4 S: burrito G0=G1 peak mean L: esculentum G0=G1 peak mean · 1 96 ð4Þ Conversion of mass values into base-pair numbers was achieved according to the factor 1 pg = 978 Mbp (Doležel et al., 2003).”
MethodInfluentialSelf-citationPlant DNA Flow Cytometry and Estimation of Nuclear Genome Size
DOLEZEL, J. (2005) · Annals of Botany · doi:10.1093/aob/mci005 · Cited by 1,053 · cited 9×
“Four common nuclear isolation buffers (Doležel and Bartoš, 2005) were used to prepare samples (Table 2).”
BackgroundMethodInfluentialAnalysis of Nuclear DNA content in plant cells by Flow cytometry
Dpooležel, J., Binarová, P., & Lcretti, S. (1989) · Biologia Plantarum · doi:10.1007/bf02907241 · Cited by 674 · cited 4×
“…esculentum ‘Stupické’ Solanaceae 1.96 Doležel et al. (1992) Celtis australis Ulmaceae 2.46 Rodriguez et al. (2005a) Pisum sativum ‘Ctirad’ Fabaceae 9.09 Doležel et al. (1989) Festuca rothmaleri Poaceae 13.67 J. Loureiro (unpubl. data) Vicia faba ‘Inovec’ Fabaceae 26.90 Doležel et al.…”
BackgroundMethodInfluentialDolezel, J., Sgorbati, S., & Lucretti, S. (1992) · Physiologia Plantarum · doi:10.1034/j.1399-3054.1992.850410.x · Cited by 646
Plant Genome Size Estimation by Flow Cytometry: Inter-laboratory Comparison*1
DOLEEL, J. (1998) · Annals of Botany · doi:10.1006/anbo.1998.0730 · Cited by 523 · cited 1×
“In fact, Doležel et al. (1998) observed differences in peak ratios obtained in different laboratories.”
ResultSelf-citationPlant Genome Size Estimation by Flow Cytometry: Inter-laboratory Comparison
Doležel, J., Greilhuber, J., Lucretti, S., Meister, A., Lysák, M. A., Nardi, L., & Obermayer, R. (1998) · Annals of Botany · doi:10.1093/oxfordjournals.aob.a010312 · Cited by 425
Self-citationPractical Flow Cytometry, 4th Edition
Ng, V. L. (2004) · Shock · doi:10.1097/00024382-200401000-00017 · Cited by 346
Genome Size Evolution in Plants
BENNETT, M. D., & LEITCH, I. J. (2005) · The Evolution of the Genome · doi:10.1016/b978-012301463-4/50004-8 · Cited by 196 · cited 1×
“Among later investigators, Ulrich and Ulrich (1986), Ulrich et al. (1988) and Bergounioux et al. (1988, 1992) employed a modified approach in which cell nuclei were released after hypotonic lysis of intact protoplasts.”
Background
Cited by
Estimation of nuclear DNA content in plants using flow cytometry
Doležel, J., Greilhuber, J., & Suda, J. (2007) · Nature Protocols · doi:10.1038/nprot.2007.310 · Cited by 1,639
Self-citationTwo New Nuclear Isolation Buffers for Plant DNA Flow Cytometry: A Test with 37 Species
Loureiro, J., Rodriguez, E., Dolezel, J., & Santos, C. (2007) · Annals of Botany · doi:10.1093/aob/mcm152 · Cited by 735
Self-citationNuclear DNA amounts in angiosperms: targets, trends and tomorrow
Bennett, M. D., & Leitch, I. J. (2011) · Annals of Botany · doi:10.1093/aob/mcq258 · Cited by 306
Pellicer, J., Powell, R. F., & Leitch, I. J. (2021) · Methods in Molecular Biology · doi:10.1007/978-1-0716-0997-2_17 · Cited by 205
Brito, G., Lopes, T., Loureiro, J., Rodriguez, E., & Santos, C. (2010) · Trees · doi:10.1007/s00468-010-0442-9 · Cited by 44
“…plant material (SD \ 0.003 independently of the number of replicates that varied between 5 and 15) in the different dates of analyses and correspondingly by possible technical related issues, such as instrumental drifts (known to account for up to 3% of FCM differences; Loureiro et al. 2006a, b).”
BackgroundSelf-citation
Metadata
- Authors
- LOUREIRO, J., RODRIGUEZ, E., DOLEŽEL, J., & SANTOS, C.
- Venue
- Annals of Botany
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-07-04
- Volume
- 98
- Issue
- 3
- Pages
- 679-689
- ISSN
- 0305-7364 (ISSN-L)
- 1095-8290
- OpenAlex
- W2066730722
- Cited by
- 179
- References
- 17
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.