Stent development and local drug delivery

Open access
Regar, E, Sianos, G, Serruys, P W·2001·British Medical Bulletin

Abstract

Stent implantation has become the new standard angioplasty procedure. In-stent re-stenosis remains the major limitation of coronary stenting. Re-stenosis is related to patient-, lesion- and procedure-specific factors. Patient-specific factors can not be influenced to any extent. Procedure-specific factors are affected by implantation technique and stent characteristics. Design and material influence vascular injury and humoral and cellular response. Radiation has been shown to have inhibitory effects on smooth muscle cell growth and neo-intima formation, but in clinical trials the outcome has been hampered by re-stenosis at the edges of the radioactive stent ('candy wrapper'). New approaches target pharmacological modulation of local vascular biology by local administration of drugs. This allows for drug application at the precise site and time of vessel injury. Systemic release is minimal and this may reduce the risk of toxicity. The drug and the delivery vehicle must fulfil pharmacological, pharmacokinetic and mechanical requirements and the application of eluting degradable matrices seems to be a possible solution. Numerous pharmacological agents with antiproliferative properties are currently under clinical investigation, e.g. actinomycin D, rapamycin or paclitaxel. Another approach is for stents to be made of biodegradable materials as an alternative to metallic stents. Their potential long-term complications, such as in-stent re-stenosis and the inaccessibility of the lesion site for surgical revascularization, needs to be assessed. Current investigational devices and the line of (pre)clinical investigation are discussed in detail. Currently, there is little experimental, and only preliminary clinical, understanding of the acute and long-term effects of drug-eluting or biodegradable stents in coronary arteries. The clinical benefit of these approaches still has to be proven.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/bmb/59.1.227

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 158

Metadata

Authors
Regar, E., Sianos, G., & Serruys, P. W.
Venue
British Medical Bulletin
Published
2001-10-01
Volume
59
Issue
1
Pages
227-248
ISSN
  • 0007-1420 (ISSN-L)
  • 1471-8391
OpenAlex
W2060790398
Cited by
158
References
2
FWCI
5.90
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stent development and local drug delivery. https://app.cochat.ai/papers/10.1093/bmb/59.1.227
The paper
Regar, E., Sianos, G., & Serruys, P. W. (2001). Stent development and local drug delivery. British Medical Bulletin. https://doi.org/10.1093/bmb/59.1.227

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.